Combination in Two-Part Dental Implant Systems: An In Vitro Examination

被引:0
|
作者
Harder, Sonke [1 ,4 ]
Freitag-Wolf, Sandra [2 ]
Quabius, Elgar Susanne [3 ]
Becker, Merlind [1 ]
Kern, Med Dent Matthias [1 ]
机构
[1] Christian Albrechts Univ Kiel, Dr Med Dent Dept Prosthodont, Propaedeut & Dent Mat, Kiel, Germany
[2] Univ Hosp Schleswig Holstein, Dipl Stat Dr Rer Nat lnstitute Med lnformat & Stat, Campus Kiel, Kiel, Germany
[3] Christian Albrechts Univ Kiel, Dept Otorhinolaryngol, Head & Neck Surg, Kiel, Germany
[4] Christian Albrechts Univ Kiel, Dept Prosthodont, Propaedeut & Dent Mat, Arnold Heller Str 16, D-24105 Kiel, Germany
关键词
ABUTMENT INTERFACE; SEALING CAPABILITY; BACTERIAL-COLONIZATION; ZIRCONIA ABUTMENTS; MICROGAP LOCATION; BONE MORPHOLOGY; PYROGEN TEST; FOLLOW-UP; CONNECTION; TITANIUM;
D O I
10.11607/ijp.7732
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To test a newly introduced implant-abutment material combination against bacterial endotoxin leakage in a human whole blood assay. Materials and Methods: Two dental implant systems with internal connections and the following material combinations at the implant-abutment interface (IAI) were used (implant material/abutment material): yttrium-stabilized tetragonal zirconium dioxide (Y-TZP)/ polyetherketoneketone (PEKK), and titanium (Ti/Ti). Test implants were inoculated with lipopolysaccharide (LPS) and sealed and submerged in human whole blood. Untreated implants served as the control groups. Changes in gene expression levels of inflammatory markers indicating LPS leakage were assessed after 1, 8, and 24 hours using quantitative real-time polymerase chain reaction. Results: In the Y-TZP/PEKK test group, a significant influence of the implant system (P < .001) on increases in gene expression indicating leakage were detected after 8 hours for TLR-4 and after 24 hours for interleukin 1-i3 and nuclear factor kappa-light-chain-enhancer of activated B-cells (NF-KB), indicating microleakage of LPS at the IAI. In the Ti/Ti test group, differences in gene expression were found only for NF-KB after 8 hours. Conclusion: The internal hexalobe IAI of two-piece dental implants fabricated from Y-TZP and PEKK do not prevent LPS molecular microleakage
引用
收藏
页码:761 / 769
页数:9
相关论文
共 50 条
  • [1] Two-part set systems
    Erdos, Peter L.
    Daniel Gerbner
    Nathan Lemons
    Mubayi, Dhruv
    Cory Palmer
    Balazs Patkos
    [J]. ELECTRONIC JOURNAL OF COMBINATORICS, 2012, 19 (01):
  • [2] Examining the Case for Dental Hygienists' Teaching Predoctoral Dental Students: A Two-Part StudyKeywords
    Owens, Yanira A.
    DeStaffany, Amy M.
    Crow, Meghan E.
    Johnson, Lonnie R.
    Tilliss, Terri S.
    Johnson, Rachel L.
    McNair, Bryan K.
    [J]. JOURNAL OF DENTAL EDUCATION, 2019, 83 (12) : 1427 - 1435
  • [3] Two-part IEEE Transactions on Systems, Man, and Cybernetics
    Sage, AP
    [J]. IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS PART A-SYSTEMS AND HUMANS, 1996, 26 (01): : 1 - 1
  • [4] 'Two-part inventions'
    不详
    [J]. CLAVIER, 2006, 45 (01): : 38 - 38
  • [5] A 'Two-Part Invention'
    Constantine, D
    [J]. POETRY REVIEW, 1998, 88 (04): : 97 - 98
  • [6] A 'Two-Part Invention'
    Powell, N
    [J]. TLS-THE TIMES LITERARY SUPPLEMENT, 1999, (4997): : 29 - 29
  • [7] 'Two-Part Inventions'
    Merry, J
    [J]. CLAVIER, 2000, 39 (04): : 48 - 48
  • [8] 'TWO-PART INVENTION'
    CARRUTH, H
    [J]. AMERICAN POETRY REVIEW, 1976, 5 (02): : 3 - 3
  • [9] The Two-Part Tariff
    Lewis, W. Arthur
    [J]. ECONOMICA-NEW SERIES, 1941, 8 (31): : 249 - 270
  • [10] In Vitro Osteogenic Properties of Two Dental Implant Surfaces
    Monjo, Marta
    Petzold, Christiane
    Ramis, Joana Maria
    Lyngstadaas, Staale Petter
    Ellingsen, Jan Eirik
    [J]. INTERNATIONAL JOURNAL OF BIOMATERIALS, 2012, 2012