共 50 条
International Society for the Advancement of Cytometry Cell Sorter Biosafety Standards
被引:38
|作者:
Holmes, Kevin L.
[1
]
Fontes, Benjamin
[2
]
Hogarth, Philip
[3
]
Konz, Richard
[4
]
Monard, Simon
[5
]
Pletcher, Charles H., Jr.
[6
]
Wadley, Robert B.
[7
]
Schmid, Ingrid
[8
]
Perfetto, Stephen P.
[9
]
机构:
[1] NIAID, Flow Cytometry Sect, NIH, Bethesda, MD 20892 USA
[2] Yale Univ, New Haven, CT USA
[3] Anim Hlth & Vet Labs Agcy, Flow Cytometry Facil, Weybridge, Surrey, England
[4] Univ Massachusetts, Sch Med, Dept Med, Worcester, MA USA
[5] Walter & Eliza Hall Inst Med Res, Cytometry Lab, Parkville, Vic 3050, Australia
[6] Univ Penn, Dept Pathol & Lab Med, Perelman Sch Med, Philadelphia, PA USA
[7] Mater Med Res Inst, Dendrit Cell Program, South Brisbane, Qld, Australia
[8] Univ Calif Los Angeles, David Geffen Sch Med, Dept Hematol Oncol, Los Angeles, CA 90095 USA
[9] NIH, Flow Cytometry Core Facil, Vaccine Res Ctr, Bethesda, MD 20892 USA
关键词:
flow cytometry;
occupational health;
biohazards;
cell sorting;
biosafety;
aerosol containment;
LABORATORY-ASSOCIATED INFECTIONS;
HUMAN-IMMUNODEFICIENCY-VIRUS;
ACQUIRED INFECTIONS;
UNFIXED CELLS;
TRANSMISSION;
AEROSOL;
CONTAINMENT;
WORKER;
D O I:
10.1002/cyto.a.22454
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
Flow cytometric cell sorting of biological specimens has become prevalent in basic and clinical research laboratories. These specimens may contain known or unknown infectious agents, necessitating precautions to protect instrument operators and the environment from biohazards arising from the use of sorters. To this end the International Society of Analytical Cytology (ISAC) was proactive in establishing biosafety guidelines in 1997 (Schmid et al., Cytometry 1997;28:99-117) and subsequently published revised biosafety standards for cell sorting of unfixed samples in 2007 (Schmid et al., Cytometry Part A J Int Soc Anal Cytol 2007;71A:414-437). Since their publication, these documents have become recognized worldwide as the standard of practice and safety precautions for laboratories performing cell sorting experiments. However, the field of cytometry has progressed since 2007, and the document requires an update. The new Standards provides guidance: (1) for laboratory design for cell sorter laboratories; (2) for the creation of laboratory or instrument specific Standard Operating Procedures (SOP); and (3) on procedures for the safe operation of cell sorters, including personal protective equipment (PPE) and validation of aerosol containment. Published (c) 2013 Wiley Periodicals Inc.(dagger</SUP)