Mortality After Paclitaxel-Coated Device Use in Dialysis Access: A Systematic Review and Meta-Analysis

被引:42
|
作者
Dinh, Krystal [1 ]
Limmer, Alexandra M. [2 ]
Paravastu, Sharath C., V [3 ]
Thomas, Shannon D. [4 ,5 ,6 ]
Bennett, Michael H. [5 ,7 ]
Holden, Andrew [8 ]
Varcoe, Ramon L. [4 ,5 ,6 ]
机构
[1] Westmead Hosp, Dept Vasc Surg, Westmead, NSW, Australia
[2] Westmead Hosp, Dept Surg, Westmead, NSW, Australia
[3] Gloucestershire Hosp NHS Fdn Trust, Dept Vasc Surg, Gloucester, Glos, England
[4] Prince Wales Hosp, Dept Surg, Sydney, NSW, Australia
[5] Univ New South Wales, Fac Med, Sydney, NSW, Australia
[6] Prince Wales Hosp, Vasc Inst, Sydney, NSW, Australia
[7] Prince Wales Hosp, Dept Anaesthesia, Sydney, NSW, Australia
[8] Auckland Hosp, Dept Intervent Radiol, Auckland, New Zealand
关键词
arteriovenous fistula; arteriovenous graft; balloon angioplasty; drug-coated balloon; drug-eluting stents; failing dialysis access; hemodialysis; mortality; paclitaxel; stenosis; PLAIN BALLOON ANGIOPLASTY; CENTRAL VENOUS STENOSIS; ADJUVANT CHEMOTHERAPY; BREAST-CANCER; HEMODIALYSIS; FISTULAS; DOXORUBICIN; TAXOL; CYCLOPHOSPHAMIDE; OUTCOMES;
D O I
10.1177/1526602819872154
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To report the risk of all-cause mortality in patients who underwent dialysis access treatment using paclitaxel-coated devices compared with percutaneous transluminal angioplasty (PTA) with an uncoated balloon. Materials and Methods: A systematic review and meta-analysis of randomized controlled trials were performed to investigate the mortality outcomes associated with paclitaxel-coated devices in the treatment of patients with a failing dialysis access (last search date February 28, 2019). The primary endpoint was all-cause mortality. This analysis included 8 studies comparing paclitaxel-coated balloon (PCB) angioplasty (n=327) and PTA (n=331) in the treatment of failing dialysis access. None investigated paclitaxel-coated stents. Mortality data were pooled using a random effects model. Statistical heterogeneity was evaluated with a chi-square test and the I-2 statistic. Summary statistics are expressed as relative risk ratios (RR) with a 95% confidence interval (CI). Results: At the pooled mean follow-up of 13.5 months (median 12, range 6-24) all-cause mortality was similar in the PCB group (13.8%) compared with PTA (11.2%; RR 1.26, 95% CI 0.85 to 1.89, p=0.25; I-2=0%). Subgroup analysis, stratified according to length of follow-up, confirmed that there were no statistically significant differences in mortality at short- and midterm follow-up [6-month (8 studies): 5.2% vs 4.8%, RR 1.24, 95% CI 0.62 to 2.47, p=0.55; 12-month (6 studies): 6.3% vs 6.0%, RR 1.06, 95% CI 0.43 to 2.63, p=0.90; and 24-month (3 studies): 19.0% vs 13.5% RR, 1.38, 95% CI 0.90 to 2.12, p=0.14). Conclusion: The analysis found no difference in short- to midterm mortality among patients treated with a drug-coated balloon compared with PTA. With proven benefit and no evidence of harm, the authors recommend ongoing use of PCB for the failing dialysis access.
引用
收藏
页码:600 / 612
页数:13
相关论文
共 50 条
  • [1] Mortality Rates After Paclitaxel-Coated Device Use in Patients With Occlusive Femoropopliteal Disease: An Updated Systematic Review and Meta-Analysis of Randomized Controlled Trials
    Dinh, Krystal
    Limmer, Alexandra M.
    Chen, Andy Z. L.
    Thomas, Shannon D.
    Holden, Andrew
    Schneider, Peter A.
    Varcoe, Ramon L.
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2021, 28 (05) : 755 - 777
  • [2] Mortality After Paclitaxel-Coated Device Use in Patients With Chronic Limb-Threatening Ischemia: A Systematic Review and Meta-Analysis of Randomized Controlled Trials
    Dinh, Krystal
    Gomes, Miguel Lemos
    Thomas, Shannon D.
    Paravastu, Sharath C., V
    Holden, Andrew
    Schneider, Peter A.
    Varcoe, Ramon L.
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2020, 27 (02) : 175 - 185
  • [3] A systematic review and meta-analysis of the risk of death and patency after application of paclitaxel-coated balloons in the hemodialysis access
    Chen, Xiyang
    Liu, Yang
    Wang, Jiarong
    Zhao, Jichun
    Singh, Niten
    Zhang, Wayne W.
    [J]. JOURNAL OF VASCULAR SURGERY, 2020, 72 (06) : 2186 - +
  • [4] Safety of paclitaxel-coated devices in the femoropopliteal arteries: A systematic review and meta-analysis
    Zhang, Chenyang
    Yin, Guosheng
    [J]. PLOS ONE, 2022, 17 (10):
  • [5] Mortality and Paclitaxel-Coated Devices An Individual Patient Data Meta-Analysis
    Rocha-Singh, Krishna J.
    Duval, Sue
    Jaff, Michael R.
    Schneider, Peter A.
    Ansel, Gary M.
    Lyden, Sean P.
    Mullin, Christopher M.
    Ioannidis, John P. A.
    Misra, Sanjay
    Tzafriri, Abraham R.
    Edelman, Elazer R.
    Granada, Juan F.
    White, Christopher J.
    Beckman, Joshua A.
    [J]. CIRCULATION, 2020, 141 (23) : 1859 - 1869
  • [6] Paclitaxel-Coated Balloon Versus Plain Balloon Angioplasty for Hemodialysis Access Maintenance: A Systematic Review and Updated Meta-analysis
    Chen, Xiyang
    Liu, Yang
    Wang, Jiarong
    Zhao, Jichun
    Singh, Niten
    Zhang, Wayne
    [J]. JOURNAL OF VASCULAR SURGERY, 2020, 72 (01) : E14 - E15
  • [7] Mortality Increase and Paclitaxel-Coated Device Use A Plausible But Inconclusive Hypothesis
    Cortese, Bernardo
    Granada, Juan F.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (24) : 2538 - 2540
  • [8] Paclitaxel-Coated versus Uncoated Balloon for Femoropopliteal In-Stent Restenosis: A Systematic Review and Meta-Analysis
    Li, Qiwei
    Wang, Li
    Zhu, Lu
    Wu, Yong
    Wu, Limin
    Liu, Hanmin
    [J]. REVIEWS IN CARDIOVASCULAR MEDICINE, 2022, 23 (09)
  • [9] Paclitaxel-coated versus sirolimus-coated balloon angioplasty for coronary artery disease: A systematic review and meta-analysis
    Shin, Doosup
    Singh, Mandeep
    Shlofmitz, Evan
    Scheller, Bruno
    Latib, Azeem
    Kandzari, David E.
    Zaman, Azfar
    Mylotte, Darren
    Dakroub, Ali
    Malik, Sarah
    Sakai, Koshiro
    Jeremias, Allen
    Moses, Jeffrey W.
    Shlofmitz, Richard A.
    Stone, Gregg W.
    Ali, Ziad A.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2024,
  • [10] Mortality and mode of dialysis: meta-analysis and systematic review
    Chander, Subhash
    Luhana, Sindhu
    Sadarat, F. N. U.
    Parkash, O. M.
    Rahaman, Zubair
    Wang, Hong Yu
    Kiran, F. N. U.
    Lohana, Abhi Chand
    Sapna, F. N. U.
    Kumari, Roopa
    [J]. BMC NEPHROLOGY, 2024, 25 (01)