A coupled subsample displacement estimation method for ultrasound-based strain elastography

被引:42
|
作者
Jiang, Jingfeng [1 ,2 ]
Hall, Timothy J. [2 ]
机构
[1] Michigan Technol Univ, Coll Engn, Dept Biomed Engn, Houghton, MI 49931 USA
[2] Univ Wisconsin, Madison Sch Med & Publ Hlth, Dept Med Phys, Madison, WI 53705 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2015年 / 60卷 / 21期
关键词
ultrasound; elasticity imaging; elastography; speckle tracking; strain elastography; shear strain; VELOCITY ESTIMATION; IN-VITRO; ELASTICITY; SPECKLE; TISSUE; ALGORITHM; TRACKING; IMAGES; MASSES; MODEL;
D O I
10.1088/0031-9155/60/21/8347
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Obtaining accurate displacement estimates along both axial (parallel to the acoustic beam) and lateral (perpendicular to the beam) directions is an important task for several clinical applications such as shear strain imaging, modulus reconstruction and temperature imaging, where a full description of the two or three-dimensional (2D/3D) deformation field is required. In this study we propose an improved speckle tracking algorithm where axial and lateral motion estimations are simultaneously performed to enhance motion tracking accuracy. More specifically, using conventional ultrasound echo data, this algorithm first finds an iso-contour in the vicinity of the peak correlation between two segments of the pre- and post-deformation ultrasound radiofrequency echo data. The algorithm then attempts to find the center of the iso-contour of the correlation function that corresponds to the unknown (sub-sample) motion vector between these two segments of echo data. This algorithm has been tested using computer-simulated data, studies with a tissue-mimicking phantom, and in vivo breast lesion data. Computer simulation results show that the method improves the accuracy of both lateral and axial tracking. Such improvements are more significant when the deformation is small or along the lateral direction. Results from the tissue-mimicking phantom study are consistent with findings observed in computer simulations. Using in vivo breast lesion data we found that, compared to the 2D quadratic subsample displacement estimation methods, higher quality axial strain and shear strain images (e.g. 18.6% improvement in contrast-to-noise ratio for shear strain images) can be obtained for large deformations (up to 5% frame-to-frame and 15% local strains) in a multi-compression technique. Our initial results demonstrated that this conceptually and computationally simple method could improve the image quality of ultrasound-based strain elastography with current clinical equipment.
引用
收藏
页码:8347 / 8364
页数:18
相关论文
共 50 条
  • [1] Alternating direction method of multipliers for displacement estimation in ultrasound strain elastography
    Ashikuzzaman, Md
    Peng, Bo
    Jiang, Jingfeng
    Rivaz, Hassan
    [J]. MEDICAL PHYSICS, 2024, 51 (05) : 3521 - 3540
  • [2] Two-dimensional autocorrelation method for ultrasound-based strain estimation
    Shamdasani, V
    Kim, Y
    [J]. PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 1380 - 1383
  • [3] A Tissue Mechanics Based Method to Improve Tissue Displacement Estimation in Ultrasound Elastography
    Kheirkhah, Niusha
    Dempsey, Sergio C. H.
    Rivaz, Hassan
    Samani, Abbas
    Sadeghi-Naini, Ali
    [J]. 42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 2051 - 2054
  • [4] A New Time Delay Estimation Method for Displacement Estimation in Ultrasound Elastography
    Khadem, A.
    Setarehdan, S. Kamaledin
    [J]. ICSP: 2008 9TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, VOLS 1-5, PROCEEDINGS, 2008, : 2127 - 2130
  • [5] Estimation of 2D displacement and strain field in high frequency ultrasound based elastography
    Vogt, M
    Perrey, C
    Ermert, H
    [J]. 2004 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-3, 2004, : 376 - 379
  • [6] Efficacy Of Kriging Interpolation In Ultrasound Imaging; Subsample Displacement Estimation
    Rebholz, Brandon
    Almekkawy, Mohamed
    [J]. 42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 2137 - 2141
  • [7] A GPU-Accelerated 3-D Coupled Subsample Estimation Algorithm for Volumetric Breast Strain Elastography
    Peng, Bo
    Wang, Yuqi
    Hall, Timothy J.
    Jiang, Jingfeng
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (04) : 694 - 705
  • [8] Ultrasound-based liver elastography in the assessment of fibrosis
    Fang, C.
    Lim, A.
    Sidhu, P. S.
    [J]. CLINICAL RADIOLOGY, 2020, 75 (11) : 822 - 831
  • [9] SMOOTHING-SPLINE BASED STRAIN ESTIMATION IN ULTRASOUND ELASTOGRAPHY
    Khadem, A.
    Setarehdan, S. K.
    [J]. ICSPC: 2007 IEEE INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING AND COMMUNICATIONS, VOLS 1-3, PROCEEDINGS, 2007, : 680 - 683
  • [10] VISCOELASTICITY MEASUREMENT- A NEW ULTRASOUND-BASED ELASTOGRAPHY METHOD IN THE ASSESSMENT OF THE KIDNEY
    Felix-Mihai, Maralescu
    Bob, Flaviu
    Grosu, Iulia Dana
    Schiller, Adalberi
    Petricia, Ligia
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2023, 38 : I421 - I421