Simulation of a Supercritical CO2 Recompression Cycle with Zero Emissions

被引:5
|
作者
Zhang, Xuelei [1 ]
Yu, Liang [1 ]
Li, Ming [1 ]
Song, Piaopiao [1 ]
机构
[1] North China Elect Power Univ, Sch Energy Power & Mech Engn, 619 Yonghua North St, Baoding 071003, Peoples R China
关键词
Supercritical CO2; Zero emission; Allam cycle; CO2; capture; NET power cycle (NPC); POWER CYCLE; THERMODYNAMIC ANALYSIS; HIGH-EFFICIENCY; OPTIMIZATION; PERFORMANCE; TURBINE; GENERATION; DESIGN; PLANT;
D O I
10.1061/(ASCE)EY.1943-7897.0000711
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The NET power cycle (NPC) offers an alternative way to inherently capture combustion derived CO2 with low efficiency penalty. This manuscript improves the NPC by recompressing a portion of the recycled CO2 stream to the exit of low temperate regenerator, forming a recompression NET power cycle (RNPC). The RNPC further enhances cycle recuperation and no longer needs to input extra heat to cover the heat gap between low pressure and high pressure CO2 streams in the regenerator. The model of internal convection cooling for the turbine in sCO(2) cycle is also accomplished according to the semiempirical formula, aiming to investigate the effect of coolant flow. This manuscript respectively conducts the system multiparameter optimization for uncertain boundary parameters and the sensitivity analysis for definite boundary parameters. The simulation results show that RNPC can output 27.2 MWe more NEP than NPC without extra heat input, leading to 3.54% of the increase in net electric efficiency. RNPC's efficiency increases monotonically with not only turbine inlet temperature but inlet pressure, which indicates that RNPC has the potentiality to further improve its efficiency at higher turbine inlet temperature and inlet pressure. However, turbine outlet pressure has a nonmonotonic effect on the cycle performance, and the optimal turbine outlet pressure corresponding to the maximum cycle efficiency is about 38-42 bar. The multiparameter optimization indicates that the global optimal cycle efficiency is approximately 53.55% within the ranges of investigated parameters. The RNPC's efficiency is considerably influenced by the minimum cycle temperature (0.234%/degrees C), compressor efficiency (0.08%/%), turbine efficiency (0.355%/%), and regenerator temperature differences (0.083%/degrees C for HTR and 0.080%/degrees C for LTR). (c) 2020 American Society of Civil Engineers.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Advanced exergy analysis of recompression supercritical CO2 cycle
    Mohammadi, Z.
    Fallah, M.
    Mahmoudi, S. M. Seyed
    [J]. ENERGY, 2019, 178 : 631 - 643
  • [2] Simulation of the supercritical CO2 recompression Brayton power cycle with a high-temperature regenerator
    Reznicek, Evan P.
    Hinze, Jacob F.
    Nellis, Gregory F.
    Anderson, Mark H.
    Braun, Robert J.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2021, 229
  • [3] Second law analysis of supercritical CO2 recompression Brayton cycle
    Sarkar, Jahar
    [J]. ENERGY, 2009, 34 (09) : 1172 - 1178
  • [4] THERMO-ECONOMIC ANALYSIS OF A RECOMPRESSION SUPERCRITICAL CO2 CYCLE COMBINED WITH A TRANSCRITICAL CO2 CYCLE
    Wang, Xurong
    Wu, Yi
    Wang, Jiangfeng
    Dai, Yiping
    Xie, Danmei
    [J]. PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2015, VOL 9, 2015,
  • [5] CONTROL OF A SUPERCRITICAL CO2 RECOMPRESSION BRAYTON CYCLE DEMONSTRATION LOOP
    Conboy, T.
    Pasch, J.
    Fleming, D.
    [J]. PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2013, VOL 8, 2013,
  • [6] Control of a Supercritical CO2 Recompression Brayton Cycle Demonstration Loop
    Conboy, T.
    Pasch, J.
    Fleming, D.
    [J]. JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2013, 135 (11):
  • [7] PERFORMANCE ANALYSIS OF SUPERCRITICAL CO2 RECOMPRESSION POWER CYCLE WITH HEAT TRANSFER CHARACTERISTICS OF CO2
    Kim, Sunjin
    Cho, Yeonjoo
    Kim, Min Soo
    Kim, Minsung
    [J]. 5TH IIR INTERNATIONAL CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR), 2017, : 204 - 211
  • [8] PERFORMANCE ANALYSIS OF SUPERCRITICAL CO2 RECOMPRESSION POWER CYCLE WITH HEAT TRANSFER CHARACTERISTICS OF CO2
    Kim, Sunjin
    Cho, Yeonjoo
    Kim, Min Soo
    Kim, Minsung
    [J]. 5TH IIR INTERNATIONAL CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR), 2017, : 859 - 866
  • [9] Seasonal variation on the performance of the dry cooled supercritical CO2 recompression cycle
    Ehsan, M. Monjurul
    Duniam, Sam
    Guan, Zhiqiang
    Gurgenci, Hal
    Klimenko, Alexander
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2019, 197
  • [10] Dynamic Characteristic Study of Supercritical CO2 Recompression Brayton Cycle System
    Zhu, Qinghui
    Han, Ruiyan
    Yang, Siyuan
    Zhang, Bo
    Yang, Zhuqiang
    [J]. FRONTIERS IN ENERGY RESEARCH, 2022, 10