Qualification of a high-efficiency, gated spectrometer for x-ray Thomson scattering on the National Ignition Facility

被引:21
|
作者
Doeppner, T. [1 ]
Kritcher, A. L. [1 ]
Neumayer, P. [2 ]
Kraus, D. [3 ]
Bachmann, B. [1 ]
Burns, S. [1 ]
Falcone, R. W. [3 ,4 ]
Glenzer, S. H. [5 ]
Hawreliak, J. [1 ]
House, A. [1 ]
Landen, O. L. [1 ]
LePape, S. [1 ]
Ma, T. [1 ]
Pak, A. [1 ]
Swift, D. [1 ]
机构
[1] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
[2] Gesell Schwerionenphys, D-64291 Darmstadt, Germany
[3] Univ Calif Berkeley, Berkeley, CA 94720 USA
[4] Univ Calif Berkeley, Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
[5] SLAC Natl Accelerator Lab, Menlo Pk, CA 94309 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2014年 / 85卷 / 11期
关键词
CRYSTALS;
D O I
10.1063/1.4890253
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have designed, built, and successfully fielded a highly efficient and gated Bragg crystal spectrometer for x-ray Thomson scattering measurements on the National Ignition Facility (NIF). It utilizes a cylindrically curved Highly Oriented Pyrolytic Graphite crystal. Its spectral range of 7.4-10 keV is optimized for scattering experiments using a Zn He-alpha x-ray probe at 9.0 keV or Mo K-shell line emission around 18 keV in second diffraction order. The spectrometer has been designed as a diagnostic instrument manipulator-based instrument for the NIF target chamber at the Lawrence Livermore National Laboratory, USA. Here, we report on details of the spectrometer snout, its novel debris shield configuration and an in situ spectral calibration experiment with a Brass foil target, which demonstrated a spectral resolution of E/Delta E = 220 at 9.8 keV. (C) 2014 AIP Publishing LLC.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Improving a high-efficiency, gated spectrometer for x-ray Thomson scattering experiments at the National Ignition Facility
    Doppner, T.
    Kraus, D.
    Neumayer, P.
    Bachmann, B.
    Emig, J.
    Falcone, R. W.
    Fletcher, L. B.
    Hardy, M.
    Kalantar, D. H.
    Kritcher, A. L.
    Landen, O. L.
    Ma, T.
    Saunders, A. M.
    Wood, R. D.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [2] A High-Efficiency X-Ray Crystal Spectrometer for X-Ray Thomson Scattering
    Zhang Xiaoding
    Zhang Jiyan
    Yang Guohong
    Wet Minxi
    Hu Guangyue
    Zhao Bin
    Zheng Jian
    [J]. PLASMA SCIENCE & TECHNOLOGY, 2013, 15 (08) : 755 - 759
  • [3] A High-Efficiency X-Ray Crystal Spectrometer for X-Ray Thomson Scattering
    张小丁
    张继彦
    杨国洪
    韦敏习
    胡广月
    赵斌
    郑坚
    [J]. Plasma Science and Technology, 2013, (08) - 759
  • [4] A High-Efficiency X-Ray Crystal Spectrometer for X-Ray Thomson Scattering
    张小丁
    张继彦
    杨国洪
    韦敏习
    胡广月
    赵斌
    郑坚
    [J]. Plasma Science and Technology, 2013, 15 (08) : 755 - 759
  • [5] Gated x-ray detector for the National Ignition Facility
    Oertel, John A.
    Aragonez, Robert
    Archuleta, Tom
    Barnes, Cris
    Casper, Larry
    Fatherley, Valerie
    Heinrichs, Todd
    King, Robert
    Landers, Doug
    Lopez, Frank
    Sanchez, Phillip
    Sandoval, George
    Schrank, Lou
    Walsh, Peter
    Bell, Perry
    Brown, Matt
    Costa, Robert
    Holder, Joe
    Montelongo, Sam
    Pederson, Neal
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (10):
  • [6] Development of a high resolution x-ray spectrometer for the National Ignition Facility (NIF)
    Hill, K. W.
    Bitter, M.
    Delgado-Aparicio, L.
    Efthimion, P. C.
    Ellis, R.
    Gao, L.
    Maddox, J.
    Pablant, N. A.
    Schneider, M. B.
    Chen, H.
    Ayers, S.
    Kauffman, R. L.
    MacPhee, A. G.
    Beiersdorfer, P.
    Bettencourt, R.
    Ma, T.
    Nora, R. C.
    Scott, H. A.
    Thorn, D. B.
    Kilkenny, J. D.
    Nelson, D.
    Shoup, M., III
    Maron, Y.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [7] Advanced Gated X-Ray Imagers for Experiments at the National Ignition Facility
    Glenn, S.
    Bell, P. M.
    Benedetti, L. R.
    Bradley, D. K.
    Celeste, J.
    Heeter, R.
    Hagmann, C.
    Holder, J.
    Izumi, N.
    Kilkenny, J. D.
    Kimbrough, J.
    Kyrala, G. A.
    Simanovskaia, N.
    Tommasini, R.
    [J]. PENETRATING RADIATION SYSTEMS AND APPLICATIONS XII, 2011, 8144
  • [8] High-efficiency high-energy-resolution spectrometer for inelastic X-ray scattering
    Qian, Q
    Tyson, TA
    Cailebe, WA
    Kao, CC
    [J]. JOURNAL OF PHYSICS AND CHEMISTRY OF SOLIDS, 2005, 66 (12) : 2295 - 2298
  • [9] Radiation hardening of gated x-ray imagers for the National Ignition Facility (invited)
    Bell, P. M.
    Bradley, D. K.
    Kilkenny, J. D.
    Conder, A.
    Cerjan, C.
    Hagmann, C.
    Hey, D.
    Izumi, N.
    Moody, J.
    Teruya, A.
    Celeste, J.
    Kimbrough, J.
    Khater, H.
    Eckart, M. J.
    Ayers, J.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (10):
  • [10] Absolute calibration of the continuum x-ray spectrometer (ConSpec) at the National Ignition Facility
    MacDonald, M. J.
    Kozioziemski, B.
    MacPhee, A. G.
    Schneider, M. B.
    Ayers, J.
    Thorn, D. B.
    [J]. JOURNAL OF INSTRUMENTATION, 2019, 14