Effectiveness of different base isolation systems for seismic protection: Numerical insights into an existing masonry bell tower

被引:43
|
作者
Habieb, Ahmad Basshofi [1 ]
Valente, Marco [1 ]
Milani, Gabriele [1 ]
机构
[1] Politecn Milan, Dept Architecture Built Environm & Construct Engn, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy
关键词
Seismic isolation; Masonry bell tower; FE model; Abaqus user element; Non-linear dynamic analysis; Near fault earthquake; HOMOGENIZED LIMIT ANALYSIS; PARTIAL FAILURE MECHANISMS; PLASTIC-DAMAGE MODEL; CHURCHES; MEDIEVAL; BEHAVIOR; DESIGN; PERFORMANCE; ELEMENT;
D O I
10.1016/j.soildyn.2019.105752
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Recent earthquakes in Italy have emphasized the high seismic vulnerability of historical masonry constructions and the need of effective retrofitting interventions. This paper investigates the possibility of improving the seismic performance of a historical masonry bell tower using different types of commercial isolators: High Damping Rubber Bearing (HDRB), Lead Rubber Bearing (LRB) and Friction Pendulum System (FPS) Isolator. Detailed three-dimensional (3D) finite element (FE) models are created to characterize the behavior of the three types of isolators. Then, an Abaqus User Element (UEL) is used to represent the 3D behavior of the isolators for global seismic analyses of isolated structures. The results of cyclic shear analyses show that the proposed UEL model can accurately predict the behavior obtained through detailed 3D FE models. Non-linear dynamic analyses are performed to investigate the seismic response of the historical masonry bell tower in the original and base-isolated configurations subjected to moderate-to-high seismic actions: moreover, the effects of near fault earthquakes are analyzed. The results obtained from the numerical simulations show that the HDRBs do not ensure an adequate seismic protection of the masonry bell tower in terms of damage patterns and top displacements. On the other hand, the LRBs and FPS isolators are very effective in reducing the earthquake effects on the masonry tower: residual displacements are negligible and the isolator displacements are limited. In case of near fault earthquakes, an isolation system with higher damping and larger dimension is required to reduce the drifts of the tower and to accommodate the large displacements of the isolators.
引用
收藏
页数:16
相关论文
共 22 条
  • [1] Experimental and Numerical Results from the Seismic Study of a Masonry Bell Tower
    Ivorra, Salvador
    Pallares, Francisco J.
    Adam, Jose M.
    [J]. ADVANCES IN STRUCTURAL ENGINEERING, 2009, 12 (02) : 287 - 293
  • [2] Retrofitting Existing Masonry Structures by Using Seismic Base Isolation System
    Rawa Asaad
    Ammar Kaadan
    [J]. Arabian Journal for Science and Engineering, 2024, 49 : 5243 - 5254
  • [3] Retrofitting Existing Masonry Structures by Using Seismic Base Isolation System
    Asaad, Rawa
    Kaadan, Ammar
    [J]. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2024, 49 (04) : 5243 - 5254
  • [4] Seismic protection of light secondary systems through different base isolation systems
    Dolce, M
    Cardone, D
    [J]. JOURNAL OF EARTHQUAKE ENGINEERING, 2003, 7 (02) : 223 - 250
  • [5] Numerical insights on the seismic behavior of a non-isolated historical masonry tower
    Giovanni Castellazzi
    Antonio Maria D’Altri
    Stefano de Miranda
    Andrea Chiozzi
    Antonio Tralli
    [J]. Bulletin of Earthquake Engineering, 2018, 16 : 933 - 961
  • [6] Numerical insights on the seismic behavior of a non-isolated historical masonry tower
    Castellazzi, Giovanni
    D'Altri, Antonio Maria
    de Miranda, Stefano
    Chiozzi, Andrea
    Tralli, Antonio
    [J]. BULLETIN OF EARTHQUAKE ENGINEERING, 2018, 16 (02) : 933 - 961
  • [7] On the effectiveness of smart technologies in the seismic protection of existing buildings Part I : Masonry structures
    Mandara, A.
    Ramundo, F.
    Spina, G.
    [J]. 2008 SEISMIC ENGINEERING CONFERENCE COMMEMORATING THE 1908 MESSINA AND REGGIO CALABRIA EARTHQUAKE, PTS 1 AND 2, 2008, 1020 : 170 - 177
  • [8] Experimental and numerical dynamic identification of a historic masonry bell tower accounting for different types of interaction
    de Silva, Filomena
    Pitilakis, Dimitris
    Ceroni, Francesca
    Sica, Stefania
    Silvestri, Francesco
    [J]. SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2018, 109 : 235 - 250
  • [9] SEISMIC PROTECTION OF A HISTORICAL R/C ELEVATED WATER TANK BY DIFFERENT BASE ISOLATION SYSTEMS
    Terenzi, Gloria
    Sorace, Stefano
    Spinelli, Paolo
    Rossi, Elena
    [J]. INGEGNERIA SISMICA, 2019, 36 (02): : 137 - 158
  • [10] Seismic protection of a historical R/C elevated water tank by different base isolation systems
    Terenzi, Gloria
    Sorace, Stefano
    Spinelli, Paolo
    Rossi, Elena
    [J]. Ingegneria Sismica, 2019, 36 (02): : 137 - 158