Anatomical constraints on source models for high-resolution EEG and MEG derived from MRI

被引:0
|
作者
Srinivasan, Ramesh [1 ]
机构
[1] Univ Calif Irvine, Dept Cognit Sci, Irvine, CA 92697 USA
关键词
EEG; MEG; MRI; source localization; and surface Laplacian;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Electroencephalography (EEG) remains the primary tool for measuring changes in dynamic brain function due to disease state with the millisecond temporal resolution of neuronal activity. In recent decades EEG has been supplanted by CT and MRI for the localization of tumors and lesions in the brain. In contrast to the excellent temporal resolution of EEG, the spatial information in EEG is limited by the volume conduction of currents through the tissues of the head. We have extracted source models (position and orientation) from MRI scans to investigate the theoretical relationship between brain sources and EEG recorded on the scalp. Although detailed information about the boundaries between different tissues can also be obtained from MRI, these models are only approximate because of our relatively poor knowledge of the conductivities of the different tissue compartments in living heads. We also compare the resolution of EEG with magnetoecephalography (MEG), which offers the advantage of requiring less detail about volume conduction in the head. The brain's magnetic field depends only on the position of sources in the brain and the position and orientation of the sensors. We demonstrate that EEG and MEG space average neural activity over comparably large volumes of the brain; however, they are preferentially sensitive to sources of different orientation suggesting a complementary role for EEG and MEG. High-resolution EEG methods potentially yield much better localization of source activity in superficial brain areas. These methods do not make any assumptions about the sources, and can be easily co-registered with the brain surface derived from MRI. While there is much information to be gained by using anatomical MRI to develop models of the generators of EEG/MEG, functional neuroimaging (e.g., fMRI) signals and EEG/MEG signals are not easily related.
引用
收藏
页码:389 / 399
页数:11
相关论文
共 50 条
  • [1] Source analysis of EEG oscillations using high-resolution EEG and MEG
    Srinivasan, Ramesh
    Winter, William R.
    Nunez, Paul L.
    [J]. EVENT-RELATED DYNAMICS OF BRAIN OSCILLATIONS, 2006, 159 : 29 - 42
  • [2] Integration of EEG/MEG with MRI and fMRI - High-resolution, multimodal neuroimaging
    Liu, Zhongming
    Ding, Lei
    He, Bin
    [J]. IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2006, 25 (04): : 46 - 53
  • [3] High-resolution EEG (HR-EEG) and magnetoencephalography (MEG)
    Gavaret, M.
    Maillard, L.
    Jung, J.
    [J]. NEUROPHYSIOLOGIE CLINIQUE-CLINICAL NEUROPHYSIOLOGY, 2015, 45 (01): : 105 - 111
  • [4] High-resolution EEG (HR-EEG) and magnetoencephalography (MEG)
    Gavaret, M.
    Badier, J. -M.
    Chauvel, P.
    [J]. NEUROCHIRURGIE, 2008, 54 (03) : 185 - 190
  • [5] High-resolution source imaging in mesiotemporal lobe epilepsy: A comparison between MEG and simultaneous EEG
    Leijten, FSS
    Huiskamp, GJM
    Hilgersom, I
    van Huffelen, AC
    [J]. JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2003, 20 (04) : 227 - 238
  • [6] Accelerated High-Resolution EEG Source Imaging
    Qin, Jing
    Wu, Tianyu
    Li, Ying
    Yin, Wotao
    Osher, Stanley
    Liu, Wentai
    [J]. 2017 8TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER), 2017, : 1 - 4
  • [7] Source Localization of Sleep Spindles by High Resolution EEG/MEG Recordings
    Jeong, Eun Hye
    Han, Jooman
    Kim, Songi
    Kim, June Sik
    Chung, Chun Kee
    Lee, Hyang Woon
    [J]. NEUROLOGY, 2010, 74 (09) : A30 - A30
  • [8] Intracerebral Sources Reconstructed on the Basis of High-Resolution Scalp EEG and MEG
    da Silva, Fernando H. Lopes
    [J]. BRAIN TOPOGRAPHY, 2019, 32 (04) : 523 - 526
  • [9] Intracerebral Sources Reconstructed on the Basis of High-Resolution Scalp EEG and MEG
    Fernando H. Lopes da Silva
    [J]. Brain Topography, 2019, 32 : 523 - 526
  • [10] Equivalent physical models and formulation of equivalent source layer in high-resolution EEG imaging
    Yao, DZ
    He, B
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (21): : 3475 - 3483