Mercury-electroplated-iridium microelectrode array based sensors for the detection of heavy metal ultratraces: optimization of the mercury charge

被引:22
|
作者
Silva, PRM
El Khakani, MA
Le Drogoff, B
Chaker, M
Vijh, AK
机构
[1] INRS Energie & Mat, Varennes, PQ J3X 1S2, Canada
[2] Inst Rech Hydro Quebec, Varennes, PQ J3X 1S1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
electroanalytical sensors; microelectrodes; iridium; mercury charge; metal trace detection;
D O I
10.1016/S0925-4005(99)00252-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mercury-electroplated-Ir microelectrode array based sensors have been developed; their electroanalytical performance is investigated for the simultaneous detection of ultratraces of Pb, Cd and Zn. Two Lr microelectrode array geometries were used, namely: (i) an array of 1089 microelectrodes of 3-mu m diameter and (ii) an array of 1764 microelectrodes of 6-mu m diameter. Prior to the Hg electroplating, the arrays were systematically characterized by means of cyclic voltammetry at various scan rates ranging from 5 to 500 mV s(-1) and found to exhibit a steady-state voltammetric behavior. The effect of the Hg charge (over a range as wide as 0.05-40 mC) on the electroanalytical performance (net peak current, peak potential and peak width) of the metal trace sensors has been systematically studied by using square wave anodic stripping voltammetry (SWASV). It is clearly shown that the net peak current not only depends on the magnitude of Hg charge, but also presents a maximum value for an optimum Hg charge. Optimum Hg charges of 4 and 15 mC were identified for the 3- and 6-mu m diameter Lr microelectrodes, respectively. At the optimum Hg charges, calibration plots demonstrated good linearity for the three metal traces over a concentration range as wide as (100 ppt-1 ppm). By increasing the preconcentration time from 5 to 20 min, it is shown that the detection limit of metal ultratraces can be decreased from 100 to 20 ppt. (C) 1999 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:161 / 167
页数:7
相关论文
共 18 条
  • [1] Mercury-electroplated-iridium microelectrode array based sensors for the detection of heavy metal ultratraces: Optimization of the mercury charge
    Silva, P.R.M.
    El Khakani, M.A.
    Le Drogoff, B.
    Chaker, M.
    Vijh, A.K.
    Sensors and Actuators, B: Chemical, 1999, 60 (02): : 161 - 167
  • [2] Mercury-plated iridium-based microelectrode arrays for trace metal detection
    Cao, Zhi
    Shang, Haiping
    Wang, Yinghui
    Wang, Weibing
    2018 19TH INTERNATIONAL CONFERENCE ON ELECTRONIC PACKAGING TECHNOLOGY (ICEPT), 2018, : 1102 - 1107
  • [3] On-chip generated mercury microelectrode for heavy metal ion detection
    Zhu, XS
    Gao, C
    Choi, JW
    Bishop, PL
    Ahn, CH
    LAB ON A CHIP, 2005, 5 (02) : 212 - 217
  • [4] Development of Hg-electroplated-iridium based microelectrode arrays for heavy metal traces analysis
    Silva, PRM
    El Khakani, MA
    Chaker, M
    Champagne, GY
    Chevalet, J
    Gastonguay, L
    Lacasse, R
    Ladouceur, M
    ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) : 249 - 255
  • [5] Mercury droplet microelectrode sensor on lab-on-a-chip for heavy metal ion detection
    Zhu, XS
    Gao, C
    Choi, JW
    Bishop, PL
    Ahn, CH
    BOSTON TRANSDUCERS'03: DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2003, : 61 - 64
  • [6] Effect of the Microelectrode geometry on the diffusion behavior and the electroanalytical performance of Hg-electroplated iridium microelectrode arrays intended for the detection of heavy metal traces
    Le Drogoff, B
    El Khakani, MA
    Silva, PRM
    Chaker, M
    Vijh, AK
    ELECTROANALYSIS, 2001, 13 (18) : 1491 - 1496
  • [7] FMN-Based Fluorescent Proteins as Heavy Metal Sensors Against Mercury Ions
    Ravikumar, Yuvaraj
    Nadarajan, Saravanan Prabhu
    Lee, Chong-Soon
    Jung, Seunho
    Bae, Dong-Ho
    Yun, Hyungdon
    JOURNAL OF MICROBIOLOGY AND BIOTECHNOLOGY, 2016, 26 (03) : 530 - 539
  • [8] Mercury-plated iridium-based microelectrode arrays for trace metals detection by voltammetry: optimum conditions and reliability
    Belmont, C.
    Tercier, M.-L.
    Buffle, J.
    Fiaccabrino, G. C.
    Analytica Chimica Acta, 329 (03):
  • [9] Mercury-plated iridium-based microelectrode arrays for trace metals detection by voltammetry: Optimum conditions and reliability
    Belmont, C
    Tercier, ML
    Buffle, J
    Fiaccabrino, GC
    KoudelkaHep, M
    ANALYTICA CHIMICA ACTA, 1996, 329 (03) : 203 - 214
  • [10] MEMS based Heavy Metal: Mercury and Cadmium Ion Detection in Laminar flow of water
    Poola, Rahul Gowtham
    Juliet, A. Vimala
    Akshya, S.
    3RD INTERNATIONAL CONFERENCE ON ADVANCES IN MECHANICAL ENGINEERING (ICAME 2020), PTS 1-6, 2020, 912