Accuracy of wearable heart rate monitors in cardiac rehabilitation

被引:72
|
作者
Etiwy, Muhammad [1 ]
Akhrass, Zade [1 ]
Gillinov, Lauren [1 ]
Alashi, Alaa [1 ]
Wang, Robert [1 ]
Blackburn, Gordon [1 ]
Gillinov, Stephen M. [1 ]
Phelan, Dermot [1 ]
Gillinov, A. Marc [1 ]
Houghtaling, Penny L. [1 ]
Javadikasgari, Hoda [1 ]
Desai, Milind Y. [1 ]
机构
[1] Cleveland Clin, Heart & Vasc Inst, Cleveland, OH 44195 USA
关键词
Cardiac rehabilitation (CR); heart rate (HR); wearable; POSTMYOCARDIAL INFARCTION; PARTICIPATION; ASSOCIATION; CORONARY; GUIDELINE; EFFICACY; FAILURE;
D O I
10.21037/cdt.2019.04.08
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: To assess the accuracy of four wearable heart rate (HR) monitors in patients with established cardiovascular disease enrolled in phase II or III cardiac rehabilitation (CR). Methods: Eighty adult patients enrolled in phase II or III CR were monitored during a CR session that included exercise on a treadmill and/or stationary cycle. Participants underwent HR monitoring with standard ECG limb leads, an electrocardiographic (ECG) chest strap monitor (Polar H7), and two randomly assigned wrist-worn HR monitors (Apple Watch, Fitbit Blaze, Garmin Forerunner 235, TomTom Spark Cardio), one on each wrist. HR was recorded at rest and at 3, 5, and 7 minutes of steady-state exercise on the treadmill and stationary cycle. Results: Across all exercise conditions, the chest strap monitor (Polar H7) had the best agreement with ECG (r(c)=0.99) followed by the Apple Watch (r(c)=0.80), Fitbit Blaze (r(c)=0.78), TomTom Spark (r(c)=0.76) and Garmin Forerunner (r(c)=4.52). There was variability in accuracy under different exercise conditions. On the treadmill, only the Fitbit Blaze performed well (r(c)=0.76), while on the stationary cycle, Apple Watch (r(c)=4.89) and TomTom Spark (r(c)=4.85) were most accurate. Conclusions: In cardiac patients, the accuracy of wearable, optically based HR monitors varies, and none of those tested was as accurate as an electrode-containing chest monitor. This observation has implications for in-home CR, as electrode-containing chest monitors should be used when accurate HR measurement is imperative.
引用
收藏
页码:262 / 271
页数:10
相关论文
共 50 条
  • [1] Erratum to accuracy of wearable heart rate monitors in cardiac rehabilitation (vol 9, pg 262, 2019)
    Etiwy, Muhammad
    Akras, Zade
    Gillinov, Lauren
    Alashi, Alaa
    Wang, Robert
    Blackburn, Gordon
    Gillinov, Stephen M.
    Phelan, Dermot
    Gillinov, A. Marc
    Houghtaling, Penny L.
    Javadikasgari, Hoda
    Desai, Milind Y.
    [J]. CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2020, 10 (03) : 644 - 645
  • [2] Evaluating the Accuracy of Wearable Heart Rate Monitors
    Ge, Z.
    Prasad, P. W. C.
    Costadopoulos, N.
    Alsadoon, Abeer
    Singh, A. K.
    Elchouemi, A.
    [J]. 2016 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN COMPUTING, COMMUNICATION, & AUTOMATION (ICACCA) (FALL), 2016, : 224 - 229
  • [3] VARIABLE ACCURACY OF COMMERCIALLY AVAILABLE WEARABLE HEART RATE MONITORS
    Gillinov, A. Marc
    Etiwy, Muhammad
    Gillinov, Stephen
    Wang, Robert
    Blackburn, Gordon
    Phelan, Dermot
    Houghtaling, Penny
    Javadikasgari, Hoda
    Desai, Milind Y.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 336 - 336
  • [4] Variable Accuracy of Wearable Heart Rate Monitors during Aerobic Exercise
    Gillinov, Stephen
    Etiwy, Muhammad
    Wang, Robert
    Blackburn, Gordon
    Phelan, Dermot
    Gillinov, A. Marc
    Houghtaling, Penny
    Javadikasgari, Hoda
    Desai, Mlind Y.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (08): : 1697 - 1703
  • [5] Evaluation of Wearable Consumer Heart Rate Monitors Based on Photopletysmography
    Parak, Jakub
    Korhonen, Ilkka
    [J]. 2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 3670 - 3673
  • [6] Accuracy of Wrist-Worn Heart Rate Monitors
    Wang, Robert
    Blackburn, Gordon
    Desai, Milind
    Phelan, Dermot
    Gillinov, Lauren
    Houghtaling, Penny
    Gillinov, Marc
    [J]. JAMA CARDIOLOGY, 2017, 2 (01) : 104 - 106
  • [7] Comparison of novel wearable cardiac monitors to yield accurate exercising ECG and heart rate data in horses
    Haughan, J.
    Manriquez, M.
    Cohen, N. D.
    Robinson, M. A.
    de Solis, C. Navas
    [J]. COMPARATIVE EXERCISE PHYSIOLOGY, 2021, 17 (05) : 457 - 465
  • [8] Accuracy of heart rate measured by military-grade wearable ECG monitor compared with reference and commercial monitors
    Lindsey, Bryndan
    Hanley, C.
    Reider, L.
    Snyder, S.
    Zhou, Y.
    Bell, E.
    Shim, J.
    Hahn, J-o
    Vignos, M.
    Bar-Kochba, E.
    [J]. BMJ MILITARY HEALTH, 2023,
  • [9] Determining resting heart rate in children using wearable activity monitors
    Kapoor, Kunal
    Raywood, Emma
    Douglas, Helen
    Saul, Greg
    Correvon, Nils
    Kuzhagaliyev, Tim
    Stott, Lee
    Main, Eleanor
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2019, 54
  • [10] Accuracy of Commercial Heart Rate Monitors in Runners: A Prospective Study
    Pasadyn, Selena R.
    Soudan, Mohamad
    Gillinov, Marc
    Houghtaling, Penny
    Phelan, Dermot
    Gillinov, Nicole
    Bittel, Barbara
    Desai, Milind
    [J]. CIRCULATION, 2019, 140