THE EFFECT OF IMMEDIATE DENTIN SEALING ON THE MARGINAL ADAPTATION AND BOND STRENGTHS OF TOTAL-ETCH AND SELF-ETCH ADHESIVES

被引:41
|
作者
Duarte, Sillas, Jr. [1 ]
Buanain de Freitas, Claudia Regina [2 ]
Cury Saad, Jose Roberto [2 ]
Sadan, Avishai [1 ]
机构
[1] Case Western Reserve Univ, Dept Comprehens Care, Sch Dent Med, Cleveland, OH 44106 USA
[2] Sao Paulo State Univ, UNESP, Araraquara Sch Dent, Dept Operat Dent, Sao Paulo, Brazil
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2009年 / 102卷 / 01期
关键词
RESIN COMPOSITE RESTORATIONS; IN-VIVO; CURED COMPOSITES; STEP ADHESIVES; MICROLEAKAGE; SYSTEMS; WALLS; INCOMPATIBILITY; DEGRADATION; NANOLEAKAGE;
D O I
10.1016/S0022-3913(09)00073-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Sealing ability and bond strengths of total-etch and self-etch dentin adhesives used for immediate dentin sealing have not been assessed and established. Purpose. The purpose of this study was to determine the effectiveness of immediate dentin sealing (IDS) using total-etch or self-etch dentin adhesives on microleakage and microtensile bond strength. Material and methods. Twenty recently extracted molars were selected, and standard MOD inlay preparations were made with the gingival margins located below the cemento-enamel unction. The teeth were assigned to 4 experimental groups (n=5) according to the indirect composite restoration cementation technique used: (1) immediate dentin sealing with Adper Single Bond (TEBI); (2) conventional adhesive cementation technique using Adper Single Bond (TEAI); (3) immediate dentin sealing using Adper Prompt L-Pop (SEBI); or (4) conventional adhesive cementation technique using Adper Prompt L-Pop (SEAI). The restored teeth were thermal cycled 1,000 times between 5 degrees and 55 degrees C and then immersed in 50% ammoniacal silver nitrate. Three specimens per restoration were evaluated for microleakage, according to predefined scores, and submitted to Friedman's test (alpha-.05). The specimens were then sectioned to obtain 0.8 +/- 0.2-mm-thick sticks (with n ranging from 32 to 57 specimens) and submitted to microtensile bond strength (mu TBS) testing. The obtained data were submitted to 2-way ANOVA test (alpha=.05). Results. None of the experimental groups demonstrated complete elimination of marginal microleakage. There were significant differences in microleakage of the tested adhesives (P>.001). IDS microleakage scores were similar to those obtained using the conventional cementation technique (CCT) for both adhesives. The highest mean bond strengths were obtained with TEBI (51.1 MPa), whereas SEAI showed the lowest mean bond strengths (1.7 MPa). IDS resulted in significantly higher bond strengths than CCT (P<.001). Conclusions. Total-etch and self-etch adhesives have a significant effect on IDS. IDS resulted in high bond strengths for both adhesives; however, the microleakage was similar to that obtained with CCT (J Prosthet Dent 2009;102:1-9)
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [1] Effect of cyclic loading on the microtensile bond strengths of total-etch and self-etch adhesives
    Toledano, M
    Osorio, R
    Albaladejo, A
    Aguilera, FS
    Tay, FR
    Ferrari, M
    [J]. OPERATIVE DENTISTRY, 2006, 31 (01) : 25 - 32
  • [2] Bonding of self-etch and total-etch adhesives to carious dentin
    Yoshiyama, M
    Tay, FR
    Doi, J
    Nishitani, Y
    Yamada, T
    Itou, K
    Carvalho, RM
    Nakajima, M
    Pashley, DH
    [J]. JOURNAL OF DENTAL RESEARCH, 2002, 81 (08) : 556 - 560
  • [3] Biosilicate as a dentin pretreatment for total-etch and self-etch adhesives: In vitro study
    de Morais, Renata Costa
    Silveira, Renata Espindola
    Chinelatti, Michelle Alexandra
    Panzeri Pires-de-Souza, Fernanda de Carvalho
    [J]. INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2016, 70 : 271 - 276
  • [4] Bond strength of a total-etch and two self-etch adhesives to dentin with and without intermediate flowable liner
    Abdalla, Ali I.
    [J]. AMERICAN JOURNAL OF DENTISTRY, 2010, 23 (03): : 157 - 160
  • [5] Dentin regional bond strength of self-etch and total-etch adhesive systems
    Proenga, Jatyr P.
    Polido, Mario
    Osorio, Estrella
    Carolina, Maria
    Erhardt, G.
    Aguilera, Fatima S.
    Garcia-Godoy, Franklin
    Osorio, Raquel
    Toledano, Manuel
    [J]. DENTAL MATERIALS, 2007, 23 (12) : 1542 - 1548
  • [6] Marginal permeability of self-etch and total-etch adhesive systems
    Owens, BM
    Johnson, WW
    Harris, EF
    [J]. OPERATIVE DENTISTRY, 2006, 31 (01) : 60 - 67
  • [7] In vitro permeability of etch-and-rinse and self-etch adhesives used for immediate dentin sealing
    Sahin, Cem
    Cehreli, Zafer C.
    Yenigul, Muhittin
    Dayangac, Bulent
    [J]. DENTAL MATERIALS JOURNAL, 2012, 31 (03) : 401 - 408
  • [8] Total-etch versus self-etch
    Featherstone, RW
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2004, 135 (04): : 412 - +
  • [9] Total-etch versus self-etch
    Papazian, GA
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2004, 135 (03): : 276 - 276
  • [10] Comparative Analysis of in vitro Performance of Total-Etch and Self-Etch Adhesives
    Melkumyan, Timur V.
    Kakhkharova, Diloro J.
    Dadamova, Anjela D.
    Kamilov, Nuriddin Kh.
    Siddikova, Sitora Sh.
    Rakhmatullaeva, Shakhlo I.
    Masouleh, Seyederfan M.
    [J]. INTERNATIONAL JOURNAL OF BIOMEDICINE, 2016, 6 (04) : 283 - 286