Alternative calibration approaches to compensate the effect of co-extracted matrix components in liquid chromatography-electrospray ionisation tandem mass spectrometry analysis of pesticide residues in plant materials

被引:127
|
作者
Zrostlíková, J [1 ]
Hajslová, J [1 ]
Poustka, J [1 ]
Begany, P [1 ]
机构
[1] Inst Chem Technol, CR-16628 Prague 6, Czech Republic
关键词
calibration approaches; matrix effects; echo-peak calibration technique; response stability; pesticides;
D O I
10.1016/S0021-9673(02)01196-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The aim of this study was to evaluate the applicability of different calibration approaches in a multi- and single-residue analysis of modem pesticides in plant matrices using liquid chromatography-electrospray mass spectrometry (HPLC-ESI-MS). In the first set of experiments the determination of eight pesticides representing different groups of polar/unstable pesticides (carbamates, benzimidazoles, azoles, benzoylphenylurea) in apple samples was performed. The trueness and precision of data obtained by using: (i) external solvent standard calibration, (ii) external matrix-matched standard calibration and (iii) echo-peak internal standard calibration was compared. The last mentioned method is a novel technique providing the possibility to inject internal standard of the same identity as a target analyte, so that its retention time is close to the analyte from the sample. According to expectation, when using external standard solvent calibration the results were under- or overestimated due to suppression or enhancement of analyte's signal by matrix components. On the other hand with the use of matrix-matched calibration accurate data were obtained. With echo-peak technique accurate results comparable to those obtained by matrix calibration were obtained for six out of eight pesticides. In the second set of experiment we used the echo-peak technique to overcome the problem with the response instability in the analysis of chlormequat in pear concentrate samples. As an internal standard method the echo-peak technique provided the possibility of monitoring of signal decrease during the analytical sequence and to compensate this decrease by relating sample peak area relatively to this internal standard. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:13 / 26
页数:14
相关论文
共 50 条
  • [1] Determination of chloralose residues in animal tissues by liquid chromatography-electrospray ionisation tandem mass spectrometry
    Hunter, K
    Taylor, MJ
    Sharp, EA
    Melton, LM
    Le Bouhellec, S
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 805 (02): : 303 - 309
  • [2] Determination of the plant growth regulator chlormequat in food by liquid chromatography-electrospray ionisation tandem mass spectrometry
    Hau, J
    Riediker, S
    Varga, N
    Stadler, RH
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 878 (01) : 77 - 86
  • [3] Determination of veterinary drug residues, mycotoxins, and pesticide residues in bovine milk by liquid chromatography electrospray ionisation -tandem mass spectrometry
    Hajrulai-Musliu, Zehra
    Uzunov, Risto
    Jovanov, Stefan
    Kerluku, Maksud
    Jankuloski, Dean
    Stojkovski, Velimir
    Pendovski, Lazo
    Sasanya, James Jacob
    [J]. JOURNAL OF VETERINARY RESEARCH, 2022, 66 (02) : 215 - 224
  • [4] Quantitative analysis of clenbuterol in meat products using liquid chromatography-electrospray ionisation tandem mass spectrometry
    Guy, PA
    Savoy, MC
    Stadler, RH
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1999, 736 (1-2): : 209 - 219
  • [5] Determination of deltamethrin residues in plant materials by liquid chromatography/tandem mass spectrometry with electrospray ionization
    Zimmer, Dieter
    Philipowski, Christiane
    Posner, Birgit
    Gnielka, Agnes
    Dirr, Edgar
    Dorff, Mario
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2006, 89 (03) : 786 - 796
  • [6] Matrix effect in liquid chromatography-electrospray ionization mass spectrometry analysis of benzoxazinoid derivatives in plant material
    Villagrasa, M.
    Guillamon, M.
    Eljarrat, E.
    Barcelo, D.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1157 (1-2) : 108 - 114
  • [7] Analysis of glycerophosphoinositol by liquid chromatography-electrospray ionisation tandem mass spectrometry using a β-cyclodextrin-bonded column
    Dragani, LK
    Berrie, CP
    Corda, D
    Rotilio, D
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 802 (02): : 283 - 289
  • [8] Selection of a representative matrix for calibration in multianalyte determination of pesticides in vegetables by liquid chromatography-electrospray tandem mass spectrometry
    Vidal, JLM
    Frenich, AG
    López, TL
    Salvador, IM
    el Hassani, LH
    Benajiba, MH
    [J]. CHROMATOGRAPHIA, 2005, 61 (3-4) : 127 - 131
  • [9] Selection of a Representative Matrix for Calibration in Multianalyte Determination of Pesticides in Vegetables by Liquid Chromatography-Electrospray Tandem Mass Spectrometry
    J. L. Martínez Vidal
    A. Garrido Frenich
    T. López López
    I. Martínez Salvador
    L. Hajjaj el Hassani
    M. Hassan Benajiba
    [J]. Chromatographia, 2005, 61 : 127 - 131
  • [10] A confirmatory analysis of malachite green residues in rainbow trout with liquid chromatography-electrospray tandem mass spectrometry
    Halme, Kirsi
    Lindfors, Erja
    Peltonen, Kimmo
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 845 (01): : 74 - 79