Development of an ionic liquid based dispersive liquid-liquid microextraction method for the analysis of polycyclic aromatic hydrocarbons in water samples

被引:159
|
作者
Teresa Pena, Ma [1 ]
Carmen Casais, Ma [1 ]
Carmen Mejuto, Ma [1 ]
Cela, Rafael [1 ]
机构
[1] Univ Santiago de Compostela, Dpto Quim Analit Nutr & Bromatol, Inst Invest & Anal Alimentario, Santiago De Compostela 15782, Spain
关键词
Polycyclic aromatic hydrocarbons; Ionic liquid; Dispersive liquid-liquid microextraction; Water analysis; Liquid chromatography; BAR SORPTIVE EXTRACTION; PHASE MICROEXTRACTION; FLUORESCENCE DETECTION; GAS CHROMATOGRAPHY; PAHS;
D O I
10.1016/j.chroma.2009.07.032
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, rapid and efficient method, ionic liquid based dispersive liquid-liquid microextraction (IL-DLLME), has been developed for the first time for the determination of 18 polycyclic aromatic hydrocarbons (PAHs) in water samples. The chemical affinity between the ionic liquid (1-octyl-3-methylimidazolium hexafluorophosphate) and the analytes permits the extraction of the PAHs from the sample matrix also allowing their preconcentration. Thus, this technique combines extraction and concentration of the analytes into one step and avoids using toxic chlorinated solvents. The factors affecting the extraction efficiency, such as the type and volume of ionic liquid, type and volume of disperser solvent, extraction time, dispersion stage, centrifuging time and ionic strength, were optimised. Analysis of extracts was performed by high performance liquid chromatography (HPLC) coupled with fluorescence detection (Flu). The optimised method exhibited a good precision level with relative standard deviation values between 1.2% and 5.7%. Quantification limits obtained for all of these considered compounds (between 0.1 and 7 ng L-1) were well below the limits recommended in the EU. The extraction yields for the different compounds obtained by IL-DLLME, ranged from 90.3% to 103.8%. Furthermore, high enrichment factors (301-346) were also achieved. The extraction efficiency of the optimised method is compared with that achieved by liquid-liquid extraction. Finally, the proposed method was successfully applied to the analysis of PAHs in real water samples (tap, bottled, fountain, well, river, rainwater, treated and raw wastewater). (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:6356 / 6364
页数:9
相关论文
共 50 条
  • [1] Development of a dispersive liquid-liquid microextraction method using a lighter-than-water ionic liquid for the analysis of polycyclic aromatic hydrocarbons in water
    Medina, Giselle S.
    Reta, Mario
    [J]. JOURNAL OF SEPARATION SCIENCE, 2016, 39 (21) : 4209 - 4218
  • [2] Ionic liquid based dispersive liquid-liquid microextraction of aromatic amines in water samples
    Fan, Yun Chang
    Hu, Zheng Liang
    Chen, Mei Lan
    Tu, Chao Shen
    Zhu, Yan
    [J]. CHINESE CHEMICAL LETTERS, 2008, 19 (08) : 985 - 987
  • [3] Ionic liquid based dispersive liquid-liquid microextraction of aromatic amines in water samples
    Yun Chang Fan~a Zheng Liang Hu~b Mei Lan Chen~c Chao Shen Tu~c Yan Zhu~(a
    [J]. Chinese Chemical Letters, 2008, (08) : 985 - 987
  • [4] Dispersive Liquid-Liquid Microextraction for the Simultaneous Determination of Parent and Nitrated Polycyclic Aromatic Hydrocarbons in Water Samples
    Borges, Barbara
    Melo, Armindo
    Ferreira, Isabel M. P. L. V. O.
    Mansilha, Catarina
    [J]. ACTA CHROMATOGRAPHICA, 2018, 30 (02) : 119 - 126
  • [5] Low toxic dispersive liquid-liquid microextraction using halosolvents for extraction of polycyclic aromatic hydrocarbons in water samples
    Leong, Mei-I
    Chang, Chu-Chi
    Fuh, Ming-Ren
    Huang, Shang-Da
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (34) : 5455 - 5461
  • [6] Determination of polycyclic aromatic hydrocarbons in water samples by temperature-controlled ionic liquid dispersive liquid-liquid microextraction combined with high performance liquid chromatography
    Zhou, Qingxiang
    Gao, Yuanyuan
    [J]. ANALYTICAL METHODS, 2014, 6 (08) : 2553 - 2559
  • [7] Simultaneous Dispersive Liquid-Liquid Microextraction and Determination of Different Polycyclic Aromatic Hydrocarbons in Surface Water
    Temerdashev, Zaual
    Prasad, Surendra
    Musorina, Tatiana
    Chervonnaya, Tatiana
    Arutyunyan, Zhanna
    [J]. MOLECULES, 2022, 27 (23):
  • [8] Monitoring polycyclic aromatic hydrocarbons in seawaters and wastewaters using a dispersive liquid-liquid microextraction method
    Ramos-Dorta, Carmen V.
    Pino, Veronica
    Afonso, Ana M.
    [J]. ENVIRONMENTAL TECHNOLOGY, 2013, 34 (05) : 607 - 616
  • [9] Dispersive liquid-liquid microextraction for determination of volatile aromatic hydrocarbons in water
    Pusvaskiene, Edita
    Jurkina, Aliona
    Vickackaite, Vida
    [J]. CHEMIJA, 2009, 20 (03): : 175 - 179
  • [10] A novel dispersive liquid-liquid microextraction based on solidification of floating organic droplet method for determination of polycyclic aromatic hydrocarbons in aqueous samples
    Xu, Hui
    Ding, Zongqing
    Lv, Lili
    Song, Dandan
    Feng, Yu-Qi
    [J]. ANALYTICA CHIMICA ACTA, 2009, 636 (01) : 28 - 33