A ratiometric fluorescent chemosensor for Zn2+ in aqueous solution through an ESIPT coupled AIE process

被引:52
|
作者
Qin, Jing-can [1 ]
Wang, Bao-dui [1 ]
Yang, Zheng-yin [1 ]
Yu, Kai-chao [2 ]
机构
[1] Lanzhou Univ, Coll Chem & Chem Engn, State Key Lab Appl Organ Chem, Lanzhou 730000, Peoples R China
[2] Huazhong Univ Sci & Technol, Sch Chem & Chem Engn, Hubei Key Lab Bioinorgan Chem & Mat Med, Wuhan 430074, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Fluorescent sensor; Bis-Schiff base; Zn2+; Ratiometric; ESIPT/AIE; AGGREGATION-INDUCED EMISSION; TURN-ON; ALZHEIMERS-DISEASE; FACILE SYNTHESIS; SCHIFF-BASE; ZINC; SENSOR; PROBE; RECOGNITION; HG2+;
D O I
10.1016/j.snb.2015.10.110
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, an efficient chemosensor (HL) has been designed and synthesized based on bis-Schiff base. The sensor could detect Zn2+ ions in a ratiometric way, which might be mainly due to an ESIPT coupled AIE process. In the absence of Zn2+, the sensor displays fluorescence emission at 500 nm, on addition of Zn2+ to an aqueous solution of HL, the sensor shows significant fluorescence enhancement at 457 nm. More importantly, the detection limit for Zn2+ can reach at 10(-7) M level. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:892 / 898
页数:7
相关论文
共 50 条
  • [1] Ratiometric chemosensor for fluorescent determination of Zn2+ in aqueous ethanol
    Li, Zifan
    Xiang, Yu
    Tong, Aijun
    [J]. ANALYTICA CHIMICA ACTA, 2008, 619 (01) : 75 - 80
  • [2] Fluorescent salicylaldehyde hydrazone as selective chemosensor for Zn2+ in aqueous ethanol: a ratiometric approach
    Li, Na
    Tang, Weixin
    Xiang, Yu
    Tong, Aijun
    Jin, Peiyuan
    Ju, Yong
    [J]. LUMINESCENCE, 2010, 25 (06) : 445 - 451
  • [3] A novel ratiometric fluorescent sensor based on terpyridine derivatives for Zn2+ in aqueous solution
    Bai, Qinghong
    Jiang, Yangming
    Hu, Enming
    Lv, Libin
    Wang, Chenghui
    Xiao, Xin
    [J]. AUSTRALIAN JOURNAL OF CHEMISTRY, 2024, 77 (01)
  • [4] Carbazole incorporated ratiometric chemosensor for Zn2+
    Helal, Aasif
    Kim, Hong-Seok
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2013, 105 : 273 - 279
  • [5] A highly selective ratiometric fluorescent chemosensor for Zn2+ ion based on a polyimine macrocycle
    Shen, Kang
    Yang, Xia
    Cheng, Yixiang
    Zhu, Chengjian
    [J]. TETRAHEDRON, 2012, 68 (29) : 5719 - 5723
  • [6] An ESIPT based chromogenic and fluorescent ratiometric probe for Zn2+ with imaging in live cells and tissues
    Gharami, Saswati
    Aich, Krishnendu
    Sarkar, Deblina
    Ghosh, Paramita
    Murmu, Nabendu
    Mondal, Tapan Kumar
    [J]. NEW JOURNAL OF CHEMISTRY, 2019, 43 (04) : 1857 - 1863
  • [7] Turn-on fluorescent chemosensor for selective detection of Zn2+ in an aqueous solution: Experimental and theoretical studies
    Choi, Ye Won
    You, Ga Rim
    Lee, Jae Jun
    Kim, Cheal
    [J]. INORGANIC CHEMISTRY COMMUNICATIONS, 2016, 63 : 35 - 38
  • [8] A COLORIMETRIC CHEMOSENSOR BASED ON FLUORESCEIN FOR THE DETECTION OF Zn2+ IN AQUEOUS SOLUTION
    Wang, Wei
    Lei, Ya-Nan
    Liu, Qing-Lei
    Gao, Yan
    [J]. HETEROCYCLES, 2016, 92 (07) : 1204 - 1214
  • [9] Ratiometric fluorescent probe based on symmetric peptidyl receptor with picomolar affinity for Zn2+ in aqueous solution
    Mehta, Pramod Kumar
    Oh, Eun-Taex
    Park, Heon Joo
    Lee, Keun-Hyeung
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2017, 245 : 996 - 1003
  • [10] A Turn-on Fluorescent Chemosensor for Zn2+ Based on Quinoline in Aqueous Media
    Yong Sung Kim
    Jae Jun Lee
    Sun Young Lee
    Pan-Gi Kim
    Cheal Kim
    [J]. Journal of Fluorescence, 2016, 26 : 835 - 844