Changes in spectral Doppler measurement of Vmax after administration of an ultrasound contrast agent -: A possible new variable for the differential diagnosis of breast lesions

被引:0
|
作者
Blohmer, JU
Oellinger, H
Grineisen, Y
Paepke, S
Siewert, C
Siebert, G
Felix, R
Lichtenegger, W
机构
[1] Humboldt Univ, Fak Med, Strahlenklin & Poliklin, D-10117 Berlin, Germany
[2] Humboldt Univ, Fak Med, Inst Biothemat & Informat, D-10117 Berlin, Germany
[3] Humboldt Univ, Fak Med, Klin Frauenheilkunde & Geburtshilfe, D-10117 Berlin, Germany
关键词
ultrasound; contrast agent; breast cancer; differential diagnosis; Doppler;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: To analyze the effect of the ultrasound agent Levovist(R) on the spectral Doppler measurement of V-max in the hope of obtaining a new variable for differential diagnosis of breast lesions. Methods: Ultrasound examinations were pre-operatively conducted on 41 female patients with breast lesions. After a standardized adjustment of the Doppler, Levovist(R) (300 mg/ml) was administered intravenously as a bolus. The difference in maximum systolic flow velocity (V-max) before and after administration of Levovist(R) was determined and the sensitivity, specificity, positive and negative predictive values (npv, ppv), and odds-ratio for the detection of breast cancer based on the difference in V-max were calculated. Results: The improved measurement of V-max after administration of Levovist(R) resulted suited in a significant increase in the range of its measured value for malignant lesions (pre-Levovist(R) median 11.9 cm/s, range 7.5-18.2 cm/s; post-Levovist(R) median 11.9 cm/s, range 9.7-23.7 cm/s). The sensitivity of using the difference, between pre- and post-contrast V-max measurements for detecting breast cancer was 65.7% for a difference greater than or equal to 0.0 cm/s; the specificity was 20%, the ppv 74.2%, the npv 14.3%, and the odds-ratio 0.5. For a V-max difference greater than or equal to 3 cm/s the sensitivity was 37.1%, the specificity 100%, the ppv 100%, the npv 31.2%, and the odds-ratio infinity. Conclusion: The present experimental study suggests that the difference in V-max pre- and post-contrast medium administration might prove to be of value as an additional parameter in the differential diagnosis of focal findings of the breast.
引用
收藏
页码:164 / 170
页数:9
相关论文
共 20 条
  • [1] Role of power Doppler techniques and ultrasound contrast enhancement in the differential diagnosis of focal breast lesions
    Schroeder, RJ
    Bostanjoglo, M
    Rademaker, J
    Maeurer, J
    Felix, R
    [J]. EUROPEAN RADIOLOGY, 2003, 13 (01) : 68 - 79
  • [2] Role of power Doppler techniques and ultrasound contrast enhancement in the differential diagnosis of focal breast lesions
    Ralf-Juergen Schroeder
    Magdalena Bostanjoglo
    Juergen Rademaker
    Juergen Maeurer
    Roland Felix
    [J]. European Radiology, 2003, 13 : 68 - 79
  • [3] 3D-power Doppler ultrasound of breast lesions with a microbubble contrast agent
    Krestan, CR
    Riedl, C
    Memarsadeghi, M
    Rudas, M
    Pfarl, G
    Helbich, TH
    [J]. ACADEMIC RADIOLOGY, 2002, 9 : S384 - S385
  • [4] Videodensitometry in the examination of focal breast lesions after injection of an ultrasound contrast agent
    Blohmer, JU
    Reinhardt, M
    Schmalisch, G
    Lichtenegger, W
    Hausschild, M
    Kümmel, S
    Fischer, T
    Ohlinger, R
    Thomas, A
    [J]. ANTICANCER RESEARCH, 2006, 26 (2C) : 1691 - 1698
  • [5] Videodensitometry after injection of an ultrasound contrast agent in the examination of focal breast lesions
    Blohmer, J
    Reinhardt, M
    Schmalisch, G
    Oellinger, JJ
    Paepke, S
    Felix, R
    [J]. RADIOLOGY, 1999, 213P : 199 - 199
  • [6] Brightness Mode and Color Doppler Ultrasound in Differential Diagnosis of Breast Lesions in Saudi Females
    Hashim, Hashim A.
    Mahmoud, Mustafa Z.
    Alonazi, Batil
    Aldosary, Hassan
    Alrashdi, Jameelah S.
    Alabdulrazaq, Fahad A.
    Almowalad, Anood H.
    [J]. JOURNAL OF CLINICAL IMAGING SCIENCE, 2019, 9
  • [7] Incorporation of contrast -enhanced ultrasound in the differential diagnosis for breast lesions with inconsistent results on mammography and conventional ultrasound
    Shao, Si-Hui
    Li, Chun-Xiao
    Yao, Ming-Hua
    Li, Gang
    Li, Xing
    Wu, Rong
    [J]. CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2020, 74 (04) : 463 - 473
  • [8] Color Doppler ultrasound of liver lesions: Signal enhancement after intravenous injection of the ultrasound contrast agent Levovist(R)
    Ernst, H
    Hahn, EG
    Balzer, T
    Schlief, R
    Heyder, N
    [J]. JOURNAL OF CLINICAL ULTRASOUND, 1996, 24 (01) : 31 - 35
  • [9] Color Doppler ultrasound and spectral analysis of tumor vessels in the differential diagnosis of solid breast masses
    SahinAkyar, G
    Sumer, H
    [J]. INVESTIGATIVE RADIOLOGY, 1996, 31 (02) : 72 - 79
  • [10] Contrast-enhanced power Doppler sonography in breast lesions -: Effect on differential diagnosis after mammography and gray scale sonography
    Özdemir, A
    Kilic, K
    Özdemir, H
    Yücel, C
    Andac, S
    Çolak, M
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2004, 23 (02) : 183 - 195