Instability of a two-phase loop thermosyphon

被引:6
|
作者
Rhi, SH [1 ]
机构
[1] Korea Inst Energy Res, Waste Heat Utilizat Res Ctr, Taejon 305343, South Korea
来源
KSME INTERNATIONAL JOURNAL | 2002年 / 16卷 / 07期
关键词
instability; two-phase loop thermosyphon; Kelvin-Helmholtz instability; orifice type insert;
D O I
10.1007/BF02949731
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The instability of two-phase loop thermosyphons was investigated experimentally and analytically. Three orifice type inserts were used to study the effect of change in the pressure drop in the flow channel of the TLT on the flow instability and temperature fluctuation. It is observed that a decrease in the size of the orifice insert from 3.7 mm (no insert) to 0.71 mm drastically reduced the fluctuation of the temperature, especially at the evaporator section of the TLT. With the orifice type insert of 0.71 mm for the TLT, the overall temperature fluctuation was almost completely eliminated, especially at higher power input to the TLT. The analysis based on the Kelvin-Helmholtz instability theory seems to predict reasonable well the loop stability state of the TLT with experimentally determined constant factors.
引用
收藏
页码:1019 / 1028
页数:10
相关论文
共 50 条
  • [1] Instability of a two-phase loop thermosyphon
    Seok-Ho Rhi
    [J]. KSME International Journal, 2002, 16 : 1019 - 1028
  • [2] Visualized Experimental Investigation on the Two-phase Instability in a Closed Loop Thermosyphon
    Liu, Yun
    Li, Zhi-Gang
    Li, Yu-Hua
    Jiang, Yu-Yan
    Liang, Shi-Qiang
    [J]. Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2021, 42 (01): : 215 - 221
  • [3] Analysis of the two-phase flow, heat transfer, and instability characteristics in a loop thermosyphon
    Liu, Yun
    Li, Zhigang
    Jiang, Yuyan
    Guo, Cong
    Tang, Dawei
    [J]. NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2021, 79 (09) : 656 - 680
  • [4] Instability phenomena in a two-phase microchannel thermosyphon
    Garrity, Patrick T.
    Klausner, James F.
    Mei, Renwei
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (7-8) : 1701 - 1708
  • [5] Two-phase thermosyphon loop laterally heated
    Bielinski, H
    Mikielewicz, J
    [J]. INZYNIERIA CHEMICZNA I PROCESOWA, 2005, 26 (02): : 339 - 351
  • [6] Operation of a Two-Phase Reverse Loop Thermosyphon
    Tsai, Meng-Chang
    Kang, Shung-Wen
    Li, Heng-Yi
    Tsai, Wen-Fa
    [J]. JOURNAL OF APPLIED SCIENCE AND ENGINEERING, 2015, 18 (03): : 259 - 264
  • [7] Experimental study of instability characteristics of a CO2 two-phase thermosyphon loop
    Fang, Chunxue
    Tong, Zhen
    Zang, Guojian
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2023, 142
  • [8] Two-phase thermosyphon loop for cooling outdoor telecommunication equipments
    Samba, Ahmadou
    Louahlia-Gualous, Hasna
    Le Masson, Stephane
    Noerterhaeuser, David
    [J]. APPLIED THERMAL ENGINEERING, 2013, 50 (01) : 1351 - 1360
  • [9] HEAT TRANSFER PERFORMANCE OF A PULSATED TWO-PHASE LOOP THERMOSYPHON
    Ashraful, Islam Md.
    Ashiqur, Rahman Md.
    Mohammed, Alam
    [J]. IMECE 2008: HEAT TRANSFER, FLUID FLOWS, AND THERMAL SYSTEMS, VOL 10, PTS A-C, 2009, : 1411 - 1419
  • [10] Two-Phase Closed-Loop Thermosyphon for Electronic Cooling
    Chang, C. -C.
    Kuo, S. -C.
    Ke, M. -T.
    Chen, S. -L.
    [J]. EXPERIMENTAL HEAT TRANSFER, 2010, 23 (02) : 144 - 156