Fire hazard assessment for a green railway station

被引:7
|
作者
Chow, W. K. [1 ]
Qu, L. [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Res Ctr Fire Engn, Kowloon, Hong Kong, Peoples R China
关键词
computational fluid dynamics; timeline analysis; available safe egress time (ASET); green railway station; required safe egress time (RSET);
D O I
10.1002/fam.2189
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A green railway station adopting natural ventilation was built in Hong Kong to promote sustainable architectural design. Similar to many other green or sustainable projects, such design failed to comply with the local fire safety codes. There are potential fire hazards due to the adopted green features. Better ventilation provision would supply more air to burn the combustibles in case of fire. Performance-based design was applied using the timeline analysis to determine the fire safety provisions. In this paper, fire simulations were carried out to predict the available safe egress time (ASET) under low design fires with smoke toxicity including only the carbon monoxide concentration. Evacuation simulations were conducted to predict the required safe egress time (RSET) under low passenger loadings. Studies on human behaviour under big fires and heavy passenger loadings were not included. Problems to be encountered in this green railway station using the timeline analysis will be pointed out in this paper. ASET was estimated by computational fluid dynamics with bigger fires resulted from the green features. RSET was estimated by evacuation software under local passenger loadings. The results indicated that ASET are less than RSET under big fires with heavy passenger loadings. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:451 / 461
页数:11
相关论文
共 50 条
  • [1] Simplified risk assessment on fire hazard of LPG filling station
    Park, Kyoshik
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2017, 34 (03) : 642 - 650
  • [2] Simplified risk assessment on fire hazard of LPG filling station
    Kyoshik Park
    Korean Journal of Chemical Engineering, 2017, 34 : 642 - 650
  • [3] The evolution of HAZARD, the fire hazard assessment methodology
    Jones, WW
    FIRE TECHNOLOGY, 1997, 33 (02) : 167 - 182
  • [4] The Evolution of HAZARD, the Fire Hazard Assessment Methodology
    Walter W. Jones
    Fire Technology, 1997, 33 : 167 - 182
  • [5] Assessment of fire hazard in Pakistan
    Rafi, Muhammad Masood
    Wasiuddin, Syed
    Siddiqui, Salman Hameed
    DISASTER PREVENTION AND MANAGEMENT, 2012, 21 (01) : 71 - 84
  • [6] Forced stratification in the case of a fire in an underground railway station
    Casalé, E
    Weatherill, A
    Ouazzani, J
    Favre, P
    10TH INTERNATIONAL SYMPOSIUM ON AERODYNAMICS AND VENTILATION OF VEHICLE TUNNELS: PRINCIPLES, ANALYSIS AND DESIGN, 2000, (43): : 691 - 698
  • [7] A quantitative assessment on the design of a railway station
    Daamen, W
    COMPUTERS IN RAILWAYS VIII, 2002, 13 : 191 - 200
  • [8] A feasible heat release rate estimation approach for fire hazard assessment in green design
    Zhu, J.
    Cheng, Y. P.
    Han, S. S.
    Chow, W. K.
    JOURNAL OF BUILDING ENGINEERING, 2023, 79
  • [9] An overview of fire hazard and fire risk assessment in regulation
    Bukowski, Richard W.
    ASHRAE Transactions 2006, Vol 112, Pt 1, 2006, 112 : 387 - 393
  • [10] Road and railway tunnel fire hazard: A new measurement method for risk assessment and improvement of transit safety
    Cigada, A
    Ruggieri, D
    Zappa, E
    2005 IEEE International Workshop on Measurement Systems for Homeland Security, Contraband Detection & Personal Safety, 2005, : 89 - 94