Camera-based Measurements of Intracellular [Na plus ] in Murine Atrial Myocytes

被引:2
|
作者
Garber, Libet [1 ,2 ,3 ]
Joca, Humberto C. [1 ,2 ]
Coleman, Andrew K. [1 ,2 ]
Boyman, Liron [1 ,2 ]
Lederer, W. Jonathan [1 ,2 ]
Greiser, Maura [1 ,2 ]
机构
[1] Univ Maryland, Sch Med, Ctr Biomed Engn & Technol, College Pk, MD 20742 USA
[2] Univ Maryland, Sch Med, Dept Physiol, College Pk, MD 20742 USA
[3] Univ Maryland, Fischell Dept Bioengn, College Pk, MD 20742 USA
来源
关键词
SODIUM; RAT; FIBRILLATION; SBFI;
D O I
10.3791/59600
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Intracellular sodium concentration ([Na+]i) is an important regulator of intracellular Ca2+. Its study provides insight into the activation of the sarcolemmal Na+ /Ca2+ exchanger, the behavior of voltage-gated Na+ channels and the Na+,K+ -ATPase. Intracellular Ca2+ signaling is altered in atrial diseases such as atrial fibrillation. While many of the mechanisms underlying altered intracellular Ca2+ homeostasis are characterized, the role of [Na+]i and its dysregulation in atrial pathologies is poorly understood. [Na+]i in atrial myocytes increases in response to increasing stimulation rates. Responsiveness to external field stimulation is therefore crucial for [Na+]i measurements in these cells. In addition, the long preparation (dye-loading) and experiment duration (calibration) require an isolation protocol that yields atrial myocytes of exceptional quality. Due to the small size of mouse atria and the composition of the intercellular matrix, the isolation of high quality adult murine atrial myocytes is difficult. Here, we describe an optimized Langendorff-perfusion based isolation protocol that consistently delivers a high yield of high quality atrial murine myocytes. Sodium-binding benzofuran isophthalate (SBFI) is the most commonly used fluorescent Na+ indicator. SBFI can be loaded into the cardiac myocyte either in its salt form through a glass pipette or as an acetoxymethyl (AM) ester that can penetrate the myocyte's sarcolemmal membrane. Intracellularly, SBFI-AM is de-esterified by cytosolic esterases. Due to variabilities in membrane penetration and cytosolic deesterification each cell has to be calibrated in situ. Typically, measurements of [Na+]i using SBFI whole-cell epifluorescence are performed using a photomultiplier tube (PMT). This experimental set-up allows for only one cell to be measured at one time. Due to the length of myocyte dye loading and the calibration following each experiment data yield is low. We therefore developed an EMCCD camera-based technique to measure [Na+]i. This approach permits simultaneous [Na+]i measurements in multiple myocytes thus significantly increasing experimental yield.
引用
收藏
页数:20
相关论文
共 30 条
  • [1] Characterization of Intracellular Sodium Homeostasis in Murine Atrial Myocytes
    Garber, Libet
    Lederer, W. Jonathan
    Greiser, Maura
    BIOPHYSICAL JOURNAL, 2017, 112 (03) : 96A - 96A
  • [2] A trajectory observer for camera-based underwater motion measurements
    Berg, T
    Jouffroy, J
    Johansen, V
    OCEANS '04 MTS/IEEE TECHNO-OCEAN '04, VOLS 1- 2, CONFERENCE PROCEEDINGS, VOLS. 1-4, 2004, : 1336 - 1341
  • [3] Camera-Based Automatic System for Tool Measurements and Recognition
    Mikolajczyk, Tadeusz
    Klodowski, Adam
    Mrozinski, Adam
    9TH INTERNATIONAL CONFERENCE INTERDISCIPLINARITY IN ENGINEERING, INTER-ENG 2015, 2016, 22 : 1035 - 1042
  • [4] Accuracy and Precision in Camera-Based Fluorescence Correlation Spectroscopy Measurements
    Sankaran, Jagadish
    Bag, Nirmalya
    Kraut, Rachel Susan
    Wohland, Thorsten
    ANALYTICAL CHEMISTRY, 2013, 85 (08) : 3948 - 3954
  • [5] Intracellular Na+ Modulates Pacemaking Activity in Murine Sinoatrial Node Myocytes: An In Silico Analysis
    Morotti, Stefano
    Ni, Haibo
    Peters, Colin H.
    Rickert, Christian
    Asgari-Targhi, Ameneh
    Sato, Daisuke
    Glukhov, Alexey V.
    Proenza, Catherine
    Grandi, Eleonora
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2021, 22 (11)
  • [6] The Benefit of Distraction: Denoising Camera-Based Physiological Measurements using Inverse Attention
    Nowara, Ewa M.
    McDuff, Daniel
    Veeraraghavan, Ashok
    2021 IEEE/CVF INTERNATIONAL CONFERENCE ON COMPUTER VISION (ICCV 2021), 2021, : 4935 - 4944
  • [7] Modeling photoplethysmographic signals in camera-based perfusion measurements: optoelectronic skin phantom
    Paul, Michael
    Mota, Filipa
    Antink, Christoph Hoog
    Blazek, Vladimir
    Leonhardt, Steffen
    BIOMEDICAL OPTICS EXPRESS, 2019, 10 (09) : 4353 - 4368
  • [8] Camera-based angular resolved spectroscopy system for spatial measurements of scattered light
    Jost, Marko
    Krc, Janez
    Topic, Marko
    APPLIED OPTICS, 2014, 53 (21) : 4795 - 4803
  • [9] Camera-based speckle noise reduction for 3-D absolute shape measurements
    Zhang, Hao
    Kuschmierz, Robert
    Czarske, Juergen
    Fischer, Andreas
    OPTICS EXPRESS, 2016, 24 (11): : 2130 - 2141
  • [10] Height of Driver's Eye and Taillight Measurements from a Camera-Based Roadside Setup
    Dupuis, Yohan
    Chabani, Azzedine
    Doucet, David
    Subirats, Peggy
    SENSORS, 2019, 19 (07):