Effect of Doppler angle in diagnosis of internal carotid artery stenosis

被引:34
|
作者
Tola, Muharrem [1 ]
Yurdakul, Mehmet [1 ]
机构
[1] Turkiye Yuksek Ihtisas Hosp, Dept Radiol, TR-06100 Ankara, Turkey
关键词
color duplex ultrasonography; Doppler angle; internal carotid artery; stenosis;
D O I
10.7863/jum.2006.25.9.1187
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. The purpose of this study was to compare velocity measurements obtained with 2 fixed insonation angles and to investigate whether there is a difference in their ability in determining internal carotid artery (ICA) stenosis. Methods. Eighty-seven patients with ICA stenosis were examined with color duplex ultrasonography. Velocity measurements were made at 60 degrees and 45 degrees insonation angles, and they were compared with Bland-Altman and receiver operating characteristic curve analysis. Results. Peak systolic velocity (PSV) and end-diastolic velocity measurements obtained at the 60 degrees insonation angle were higher compared with those obtained at the 450 insonation angle (24.2% and 24.7%, respectively). The ICA-to-common carotid artery PSV ratio, conversely, was slightly higher (3.9%). Although the threshold values for the same velocity parameters obtained at 2 different insonation angles were different, the accuracy ratios (sensitivity and specificity) were not. With application of the Society of Radiologists in Ultrasound consensus criteria to the data obtained at either of the 2 insonation angles, the accuracy ratios of PSV and end-diastolic velocity were found to be statistically different. in the ICA-to-common carotid artery PSV ratio, however, there were no statistically significant differences in the accuracy ratios. Conclusions. Doppler velocity measurements made at different fixed insonation angles show considerable differences. In determining ICA stenosis, although optimal thresholds are different, the diagnostic performance is not different. in determining ICA stenosis with color duplex ultrasonography, angle-specific thresholds must be determined, and examinations must be made at a fixed angle.
引用
收藏
页码:1187 / 1192
页数:6
相关论文
共 50 条
  • [1] Influence of pulsed wave doppler angle on diagnosis of internal carotid artery stenosis
    Igarashi, H.
    Okamura, M.
    Okabe, R.
    Takekawa, H.
    Suzuki, K.
    Iizuka, K.
    Tsukahara, Y.
    Suzuki, A.
    Iwasaki, A.
    Hirata, K.
    [J]. JOURNAL OF THE NEUROLOGICAL SCIENCES, 2017, 381 : 520 - 520
  • [2] ULTRASONIC DOPPLER SPECTRAL BROADENING IN THE DIAGNOSIS OF INTERNAL CAROTID-ARTERY STENOSIS
    SHELDON, CD
    MURIE, JA
    QUIN, RO
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1983, 9 (06): : 575 - 580
  • [3] The accuracy of transcranial Doppler in the diagnosis of stenosis or occlusion of the terminal internal carotid artery
    Navarro, JC
    Mikulik, R
    Garami, Z
    Alexandrov, AV
    [J]. JOURNAL OF NEUROIMAGING, 2004, 14 (04) : 314 - 318
  • [4] Carotid Flow Volume Measurement in Doppler Ultrasound as a New Look at the Diagnosis of Internal Carotid Artery Stenosis
    Kaszczewski, Piotr
    Elwertowski, Micha
    Leszczynski, Jerzy
    Ostrowski, Tomasz
    Galazka, Zbigniew
    [J]. JOURNAL OF VASCULAR SURGERY, 2019, 70 (05) : E162 - E162
  • [5] Doppler Velocity Estimates of Internal Carotid Artery Stenosis: Angle Correction Parallel to the Color Doppler Lumen Versus Parallel to the Artery Wall
    Polak, Joseph F.
    Alessi-Chinetti, Jean M.
    Kremkau, Frederick W.
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (12) : 3211 - 3218
  • [6] Internal carotid artery stenosis: validation of Doppler velocimetric criteria
    Monteiro, A.
    Santos, R.
    Ferreira, C.
    Costa, A.
    Azevedo, E.
    [J]. CEREBROVASCULAR DISEASES, 2013, 35 : 56 - 56
  • [7] DOPPLER FEATURES OF DISTAL INTERNAL CAROTID-ARTERY STENOSIS
    WINSBERG, F
    SUDAKOFF, G
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 1994, 13 (09) : 727 - 729
  • [8] Diagnosis of internal carotid artery stenosis greater than 70% with power Doppler duplex sonography
    Koga, M
    Kimura, K
    Minematsu, K
    Yamaguchi, T
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2001, 22 (02) : 413 - 417
  • [9] RELIABILITY OF DOPPLER ULTRASOUND DIAGNOSIS IN CAROTID-ARTERY STENOSIS
    PERRIN, G
    GOUTELLE, A
    PIERLUCA, P
    CHACORNAC, R
    ALLEGRE, GE
    [J]. NEUROCHIRURGIE, 1977, 23 (03) : 215 - 225
  • [10] Early Diagnosis of Intracranial Internal Carotid Artery Stenosis Using Extracranial Hemodynamic Indices from Carotid Doppler Ultrasound
    Zhang, Xiangdong
    Wu, Dan
    Li, Hongye
    Fang, Yonghan
    Xiong, Huahua
    Li, Ye
    [J]. BIOENGINEERING-BASEL, 2022, 9 (09):