Comparison of surface mounted markers and attachment methods in estimating tibial rotations during walking: an in vivo study

被引:206
|
作者
Manal, K [1 ]
McClay, I
Stanhope, S
Richards, J
Galinat, B
机构
[1] Univ Delaware, Dept Mech Engn, Newark, DE 19716 USA
[2] NIH, Biomech Lab, Bethesda, MD 20982 USA
[3] Delaware Orthopaed Ctr, Newark, DE 19716 USA
关键词
surface-tracking marker; tibia; distal lateral shank; tibial rotation;
D O I
10.1016/S0966-6362(99)00042-9
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The overall goal of this work was to determine an optimal surface-tracking marker set Ibr tracking motion of the tibia during natural cadence walking. Eleven different marker sets were valuated. The marker sets differed in location they were attached to the shank. the method used to attach the marker sets to the segment and the physical characteristics of the marker sets. Angular position during stance for each marker set was expressed relative to the orientation of the tibia as measured using bone anchored markers. A marker set consisting of four markers attached to a rigid shell positioned over the distal lateral shank and attached to the leg using an underwrap attachment yielded the brst estimate of tibial rotation. Rotational deviations of +/- 2 degrees about the medio-lateral and antero-posterior axes. and +/- 4 degrees about the longitudinal axis did occur even when using the optimal set of markers. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:38 / 45
页数:8
相关论文
共 6 条
  • [1] A comparison of attachment methods of skin mounted inertial measurement units on tibial accelerations
    Johnson, Caleb D.
    Outerleys, Jereme
    Tenforde, Adam S.
    Davis, Irene S.
    JOURNAL OF BIOMECHANICS, 2020, 113
  • [2] Foot kinematics during walking measured using bone and surface mounted markers
    Nester, C.
    Jones, R. K.
    Liu, A.
    Howard, D.
    Lundberg, A.
    Arndt, A.
    Lundgren, P.
    Stacoff, A.
    Wolf, P.
    JOURNAL OF BIOMECHANICS, 2007, 40 (15) : 3412 - 3423
  • [3] ERRORS IN ESTIMATING TIBIAL TRANSLATION DURING NATURAL CADENCE WALKING: BONE VS. SKIN]MOUNTED TRACKING TARGETS
    Manal, K.
    McClay, I.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2001, 33 (05): : S236 - S236
  • [4] The accuracy of estimating proximal tibial translation during natural cadence walking: bone vs. skin mounted targets
    Manal, K
    Davis, IM
    Galinat, B
    Stanhope, S
    CLINICAL BIOMECHANICS, 2003, 18 (02) : 126 - 131
  • [5] Comparison of global and joint-to-joint methods for estimating the hip joint load and the muscle forces during walking
    Fraysse, F.
    Dumas, R.
    Cheze, L.
    Wang, X.
    JOURNAL OF BIOMECHANICS, 2009, 42 (14) : 2357 - 2362
  • [6] COMPARISON OF 2 METHODS OF MEASURING SPINE ANGULAR KINEMATICS DURING DYNAMIC FLEXION MOVEMENTS: SKIN-MOUNTED MARKERS COMPARED WITH MARKERS AFFIXED TO RIGID BODIES
    Howarth, Samuel J.
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2014, 37 (09) : 688 - 695