Evaluation of a novel automated water analyzer for continuous monitoring of toxicity and chemical parameters in municipal water supply

被引:7
|
作者
Bodini, Sergio F. [1 ]
Malizia, Marzio [1 ]
Tortelli, Annalisa [1 ]
Sanfilippo, Luca [1 ]
Zhou, Xingpeng [2 ]
Arosio, Roberta [3 ]
Bernasconi, Marzia [3 ]
Di Lucia, Stefano [3 ]
Manenti, Angela [3 ]
Moscetta, Pompeo [1 ]
机构
[1] SYSTEA SpA, Via Fratta Rotonda Vado Largo 2-A, I-03012 Anagni, Italy
[2] Focused Photon Inc, Water Res Dept, 760 Binan Rd, Hangzhou 310052, Zhejiang, Peoples R China
[3] Metropolitan Milanese SpA, Serv Idr Integrato, Div Acquedotto, Via Meda 44, I-20141 Milan, Italy
关键词
Water quality; Acute toxicity; Luminescent bacteria; Photobacterium phosphoreum; On-line monitoring; Automated analyzer; DIFFERENT PH LEVELS; PHOTOBACTERIUM-PHOSPHOREUM; LUMINESCENT BACTERIA; VIBRIO-FISCHERI; AQUATIC TOXICITY; DAPHNIA-MAGNA; BIOASSAY; ASSAY; ECOTOXICITY; WASTE;
D O I
10.1016/j.ecoenv.2018.03.057
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A novel tool, the DAMTA analyzer (Device for Analytical Monitoring and Toxicity Assessment), designed for fully automated toxicity measurements based on luminescent bacteria as well as for concomitant determination of chemical parameters, was developed and field-tested. The instrument is a robotic water analyzer equipped with a luminometer and a spectrophotometer, integrated on a thermostated reaction plate which contains a movable carousel with 80 cuvettes. Acute toxicity is measured on-line using a wild type Photobacterium phosphoreum strain with measurable bioluminescence and unaltered sensitivity to toxicants lasting up to ten days. The EC50 values of reference compounds tested were consistent with A. fischeri and P. phosphoreum international standards and comparable to previously published data. Concurrently, a laboratory trial demonstrated the feasibility of use of the analyzer for the determination of nutrients and metals in parallel to the toxicity measurements. In a prolonged test, the system was installed only in toxicity mode at the premises of the World Fair "Expo Milano-2015", a high security site to ensure the quality of the supplied drinking water. The monitoring program lasted for six months during which ca. 2400 toxicity tests were carried out; the results indicated a mean non-toxic outcome of -5.5 +/- 6.2%. In order to warrant the system's robustness in detecting toxic substances, Zn was measured daily with highly reproducible inhibition results, 70.8 +/- 13.6%. These results assure that this novel toxicity monitor can be used as an early warning system for protection of drinking water sources from emergencies involving low probability/high impact contamination events in source water or treated water.
引用
收藏
页码:335 / 342
页数:8
相关论文
共 50 条
  • [1] Development of a fully automated inorganic nitrogen analyzer for continuous, unattended monitoring of water quality
    Sun, BT
    John, R
    Zhao, HJ
    [J]. LABORATORY ROBOTICS AND AUTOMATION, 2000, 12 (06) : 312 - 316
  • [2] MONITORING WATER-QUALITY PARAMETERS FROM MUNICIPAL WATER INTAKES
    KUBUS, JJ
    EGLOFF, DA
    [J]. JOURNAL WATER POLLUTION CONTROL FEDERATION, 1982, 54 (12): : 1592 - 1598
  • [3] Application of a Novel Leakage Detection Framework for Municipal Water Supply on AAU Water Supply Lab
    Jensen, Tom Norgaard
    Kallesoe, Carsten Skovmose
    [J]. 2016 3RD CONFERENCE ON CONTROL AND FAULT-TOLERANT SYSTEMS (SYSTOL), 2016, : 428 - 433
  • [4] Automated Household Water Supply Monitoring & Billing System
    Rahman, Tanvir
    Ahmed, Tanzia
    Hasan, Ibteaz
    Alam, Md. Ashraful
    [J]. PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON INVENTIVE SYSTEMS AND CONTROL (ICISC 2018), 2018, : 448 - 455
  • [5] Study on Water Quality Chemical Stability of Desalinated Seawater in Municipal Water Supply Systems
    Luo, Bijun
    Zhao, Xinhua
    Liang, Baoshuang
    Dong, Guofeng
    [J]. 2009 INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND INFORMATION APPLICATION TECHNOLOGY,VOL I, PROCEEDINGS, 2009, : 344 - +
  • [6] Continuous water toxicity monitoring using immobilizedPhotobacterium phosphoreum
    Se Kwon Kim
    Baek Seok Lee
    Jeong Gun lee
    Hyung Joon Seo
    Eun Ki Kim
    [J]. Biotechnology and Bioprocess Engineering, 2003, 8 : 147 - 150
  • [7] Harbin water supply network monitoring and evaluation
    Qian, Z.
    Gao, JinLiang
    Wu, WenYan
    Hou, X. Q.
    Wu, YingBin
    Tao, L.
    Ran, Ning
    [J]. 2007 IEEE INTERNATIONAL CONFERENCE ON NETWORKING, SENSING, AND CONTROL, VOLS 1 AND 2, 2007, : 345 - +
  • [8] CONTINUOUS MONITORING OF CHEMICAL SPECIES IN WATER DISINFECTION STUDIES
    KINMAN, RN
    SCARPINO, PV
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1973, : 62 - &
  • [9] Water security: Continuous monitoring of water distribution systems for chemical agents by SERS
    Inscore, Frank
    Shende, Chetan
    Sengupta, Atanu
    Farquharson, Stuart
    [J]. OPTICS AND PHOTONICS IN GLOBAL HOMELAND SECURITY III, 2007, 6540
  • [10] Continuous water toxicity monitoring using immobilized Photobacterium phosphoreum
    Kim, SK
    Lee, BS
    Lee, JG
    Seo, HJ
    Kim, EK
    [J]. BIOTECHNOLOGY AND BIOPROCESS ENGINEERING, 2003, 8 (02) : 147 - 150