Central corneal thickness measurements with partial coherence interferometry, ultrasound, and the Orbscan system

被引:90
|
作者
Rainer, G
Findl, O
Petternel, V
Kiss, B
Drexler, W
Skorpik, C
Georgopoulos, M
Schmetterer, L
机构
[1] Univ Vienna, Dept Ophthalmol, A-1090 Vienna, Austria
[2] Univ Vienna, Inst Med Phys, Vienna, Austria
[3] Univ Vienna, Dept Clin Pharmacol, Vienna, Austria
关键词
D O I
10.1016/j.ophtha.2003.09.027
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To compare the reliability of central corneal thickness measurements (CCT) obtained with partial Coherence interferometry (PCI), ultrasound pachymetry, and the Orbscan system. Design: Cross-sectional study. Participants: Twenty healthy subjects with CCT measurements in both eyes. Methods: The CCT measurements were obtained with PCI, ultrasound pachymetry, and the Orbscan system. In each eye, 2 investigators performed 5 repeated measurements with each pachymetric device. Intraclass correlation coefficients (kappa) were calculated and mean CCT measurements were compared. Main Outcome Measures: The CCT measurements obtained with ultrasound pachymetry, the Orbscan system (Orbtek Inc., Salt Lake City, UT), and PCI. Results: Mean CCT values measured with ultrasound pachymetry were significantly thicker than those measured with PCI (21.5 mum; P<0.001) or the Orbscan system (19.8 mum; P<0.001). The correlation coefficients for the intraobserver variability were 0.999 for PCI measurements, 0.983 for ultrasound pachymetry measurements, and 0.988 for Orbscan system measurements. The correlation coefficients for the interobserver variability were 0.998 for PCI measurements, 0.980 for ultrasound pachymetry measurements, and 0.988 for Orbscan system measurements. There was a slightly better consistency between ultrasound pachymetry and PCI (kappa = 0.96) than between the Orbscan system and PCI (kappa = 0.92) and between ultrasound pachymetry and the Orbscan system (kappa = 0.89). Conclusions: Partial coherence interferometry was the method with the least intraobserver or interobserver variability. Mean CCT as measured with ultrasound pachymetry was approximately 20 Am thicker than with the Orbscan system and PCI. However, corneal thickness measurements with ultrasound pachymetry and PCI were slightly more consistent than those of the Orbscan system and PCI. This slightly better consistency, however, may be important, especially in corneal refractive surgery. Ophthalmology 2004;111:875-879 (C) 2004 by the American Academy of Ophthalmology.
引用
收藏
页码:875 / 879
页数:5
相关论文
共 50 条
  • [1] Ultrasound and partial coherence interferometry with measurement of central corneal thickness
    Much, Martin Michael
    Haigis, Wolfgang
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (07) : 665 - 670
  • [2] The reliability of central corneal thickness measurements by ultrasound and by Orbscan system in schoolchildren
    Basmak, Hikmet
    Sahin, Afsun
    Yildirim, Nilgun
    CURRENT EYE RESEARCH, 2006, 31 (7-8) : 569 - 575
  • [3] Comparison of ultrasound pachymetry and partial coherence interferometry in the measurement of central corneal thickness
    Rainer, G
    Petternel, V
    Findl, O
    Schmetterer, L
    Skorpik, C
    Luksch, A
    Drexler, W
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (12): : 2142 - 2145
  • [4] Comparison of Central Corneal Thickness Measurements with Pentacam, Orbscan II, and Ultrasound Pachymeter
    Yekta, Abbas-Ali
    Hashemi, Hassan
    KhabazKhoob, Mehdi
    Dostdar, Asghar
    Mehravaran, Shiva
    Heravian, Javad
    Fotouhi, Akbar
    IRANIAN JOURNAL OF OPHTHALMOLOGY, 2009, 21 (02): : 51 - 57
  • [5] Comparison of Orbscan and Ultrasound pachymetry in the measurement of central corneal thickness
    S W Radford
    R Lim
    J F Salmon
    Eye, 2004, 18 : 434 - 436
  • [6] Correlational study of central corneal thickness measurements on Hong Kong Chinese using optical coherence tomography, Orbscan and ultrasound pachymetry
    Wong, ACM
    Wong, CC
    Yuen, NSY
    Hui, SP
    EYE, 2002, 16 (06) : 715 - 721
  • [7] Comparison of central corneal thickness measurements by ultrasound pachymetry, Orbscan, and third generation optical coherence tomography (OCT3)
    Fishman, GR
    Pons, M
    Makornwattana, M
    Seedor, J
    Liebmann, J
    Ritch, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U5 - U5
  • [8] Comparison of Orbscan and Ultrasound pachymetry in the measurement of central corneal thickness
    Radford, SW
    Lim, R
    Salmon, JF
    EYE, 2004, 18 (04) : 434 - 436
  • [9] Correlational study of central corneal thickness measurements on Hong Kong Chinese using optical coherence tomography, Orbscan and ultrasound pachymetry
    A C-M Wong
    C-C Wong
    N S-Y Yuen
    S-P Hui
    Eye, 2002, 16 : 715 - 721
  • [10] Central corneal thickness measurements by ultrasound, Orbscan II, and Visante OCT after LASIK for myopia
    Cheng, Arthur C. K.
    Rao, Srinivas K.
    Lau, Silvania
    Leung, Chris K. S.
    Lam, Dennis S. C.
    JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (04) : 361 - 365