Computerized detection of lung nodules using energy-subtracted soft-tissue and standard digital chest images

被引:0
|
作者
Xu, X
MacMahon, H
Ashizawa, K
Engelmann, RM
Doi, K
机构
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:326 / 326
页数:1
相关论文
共 26 条
  • [1] Detection of lung nodule on digital energy subtracted soft-tissue and conventional chest images from a CR system
    Xu, XW
    MacMahon, H
    Doi, K
    [J]. COMPUTER-AIDED DIAGNOSIS IN MEDICAL IMAGING, 1999, 1182 : 63 - 69
  • [2] Usefulness of temporally subtracted images in the detection of lung nodules at digital chest radiography
    Sasaki, Y
    Katsuragawa, S
    Ishikawa, I
    MacMahon, H
    Dol, K
    [J]. RADIOLOGY, 1996, 201 : 1473 - 1473
  • [3] Adaptive feature analysis of false positives for computerized detection of lung nodules in digital chest images
    Xu, XW
    MacMahon, H
    Giger, ML
    Doi, K
    [J]. IMAGE PROCESSING - MEDICAL IMAGING 1997, PTS 1 AND 2, 1997, 3034 : 428 - 436
  • [4] Improved detection of pulmonary nodules on energy-subtracted chest radiographs with a commercial computer-aided diagnosis software: comparison with human observers
    Zsolt Szucs-Farkas
    Michael A. Patak
    Seyran Yuksel-Hatz
    Thomas Ruder
    Peter Vock
    [J]. European Radiology, 2010, 20 : 1289 - 1296
  • [5] Improved detection of pulmonary nodules on energy-subtracted chest radiographs with a commercial computer-aided diagnosis software: comparison with human observers
    Szucs-Farkas, Zsolt
    Patak, Michael A.
    Yuksel-Hatz, Seyran
    Ruder, Thomas
    Vock, Peter
    [J]. EUROPEAN RADIOLOGY, 2010, 20 (06) : 1289 - 1296
  • [6] Usefulness of Computerized Method for Lung Nodule Detection in Digital Chest Radiographs Using Temporal Subtraction Images
    Aoki, Takatoshi
    Oda, Nobuhiro
    Yamashita, Yoshiko
    Yamamoto, Keiji
    Korogi, Yukunori
    [J]. ACADEMIC RADIOLOGY, 2011, 18 (08) : 1000 - 1005
  • [7] Computerized detection of pulmonary nodules on digital chest radiographs using a contralateral subtraction technique
    Li, Q
    Katsuragawa, S
    Engelmann, RM
    MacMahon, H
    Doi, K
    [J]. RADIOLOGY, 1999, 213P : 230 - 230
  • [8] Lung Nodule Detection by Microdose CT Versus Chest Radiography (Standard and Dual-Energy Subtracted)
    Ebner, Lukas
    Buetikofer, Yanik
    Ott, Daniel
    Huber, Adrian
    Landau, Julia
    Roos, Justus E.
    Heverhagen, Johannes T.
    Christe, Andreas
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (04) : 727 - 735
  • [9] Development of an improved CAD scheme for automated detection of lung nodules in digital chest images
    Xu, XW
    Doi, K
    Kobayashi, T
    MacMahon, H
    Giger, ML
    [J]. MEDICAL PHYSICS, 1997, 24 (09) : 1395 - 1403
  • [10] Improved computerized detection of lung nodules in chest radiographs by means of "virtual dual-energy" radiography
    Chen, S.
    Suzuki, K.
    MacMahon, H.
    [J]. MEDICAL IMAGING 2011: COMPUTER-AIDED DIAGNOSIS, 2011, 7963