Determination of Cd in food using an electrothermal vaporization capacitively coupled plasma microtorch optical emission microspectrometer: Compliance with European legislation and comparison with graphite furnace atomic absorption spectrometry

被引:17
|
作者
Butaciu, Sinziana [1 ]
Frentiu, Tiberiu [1 ]
Senila, Marin [2 ]
Darvasi, Eugen [1 ]
Cadar, Sergiu [2 ]
Ponta, Michaela [1 ]
Petreus, Dorin [3 ]
Etz, Radu [3 ]
Frentiu, Maria [2 ]
机构
[1] Univ Babes Bolyai, Fac Chem & Chem Engn, Cluj Napoca 400028, Romania
[2] INCDO INOE 2000 Natl Inst Res & Dev Optoelect Buc, Res Inst Analyt Instrumentat, Cluj Napoca 400293, Romania
[3] Tech Univ Cluj Napoca, Fac Elect Telecommun & Informat Technol, Cluj Napoca 400027, Romania
关键词
Cadmium in food; Capacitively coupled plasma microtorch; Optical emission spectrometry; Graphite furnace atomic absorption spectrometry; European legislation; BIODEGRADABLE MATERIALS; MERCURY DETERMINATION; SAMPLE INTRODUCTION; WATER SAMPLES; CADMIUM; LEAD; PRECONCENTRATION; MICROEXTRACTION; NANOPARTICLES; MICROPLASMA;
D O I
10.1016/j.foodcont.2015.09.040
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
A precise, accurate and sensitive method based on electrothermal vaporization capacitively coupled plasma microtorch optical emission spectrometry for Cd determination in various dietary products was developed. The instrumentation is inexpensive as it includes a low power (15 W) and low argon consumption (150 ml min(-1)) microplasma connected to a small-sized Rh electrothermal vaporization device and a low resolution microspectrometer. The sample was subjected to microwave assisted digestion in HNO3-H2O2 mixture and Cd was determined in 10 mu l sample without preconcentration. The standard addition method was used to compensate for the non-spectral matrix effects. The new method was in-house validated by analyzing certified reference materials and test dietary samples for which the Cd maximum level was established in Commission Regulation 488/2014/EU. The figures of merit of the proposed method and the experimental results were compared to those obtained in graphite furnace atomic absorption spectrometry as standardized method and discussed in relation with the requirements in the Commission Decision 2002/657/EC and Commission Regulations 2011/836/EU and 2007/333/EC. The limit of detection in fresh sample (0.001-0.009 mg kg(-1)), limit of quantification (0.002-0.018 mg kg(-1)), recovery (103 +/- 15%), trueness (-3.0)-(+7.3)% and precision (0.8-14.0%) were similar to those found in the reference method and comply with the minimal criteria imposed to a method to be used in official laboratories for Cd determination in food. Precision for Cd determination close to maximum admitted levels or higher was of 0.8-6.0%, while for lower concentration in the range 4.0-14.0%. The Bland and Altman statistical test allowed successful evaluation of the new method as an alternative to the well established graphite-furnace atomic absorption spectrometry. The proposed method has analytical potential and is easy to run, while the full miniaturized instrumentation could be considered as a useful tool for the future as an alternative to the traditional instrumentation. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:227 / 234
页数:8
相关论文
共 50 条
  • [1] A microanalytical method based on electrothermal vaporization capacitively coupled plasma microtorch optical emission spectrometry for multielemental determination: comparison with inductively coupled plasma optical emission spectrometry
    Frentiu, Tiberiu
    Butaciu, Sinziana
    Darvasi, Eugen
    Ponta, Michaela
    Frentiu, Maria
    Petreus, Dorin
    CHEMICAL PAPERS, 2017, 71 (01) : 91 - 102
  • [2] A microanalytical method based on electrothermal vaporization capacitively coupled plasma microtorch optical emission spectrometry for multielemental determination: comparison with inductively coupled plasma optical emission spectrometry
    Tiberiu Frentiu
    Sinziana Butaciu
    Eugen Darvasi
    Michaela Ponta
    Maria Frentiu
    Dorin Petreus
    Chemical Papers, 2017, 71 : 91 - 102
  • [3] Analytical characterization of a method for mercury determination in food using cold vapour capacitively coupled plasma microtorch optical emission spectrometry - compliance with European legislation requirements
    Frentiu, Tiberiu
    Butaciu, Sinziana
    Darvasi, Eugen
    Ponta, Michaela
    Senila, Marin
    Petreus, Dorin
    Frentiu, Maria
    ANALYTICAL METHODS, 2015, 7 (02) : 747 - 752
  • [4] A graphite furnace electrothermal vaporization system for inductively coupled plasma atomic emission spectrometry
    Schäffer, U
    Krivan, V
    ANALYTICAL CHEMISTRY, 1998, 70 (03) : 482 - 490
  • [5] Application of low-cost electrothermal vaporization capacitively coupled plasma microtorch optical emission spectrometry for simultaneous determination of Cd and Pb in environmental samples
    Frentiu, Tiberiu
    Darvasi, Eugen
    Butaciu, Sinziana
    Ponta, Michaela
    Petreus, Dorin
    Etz, Radu
    Frentiu, Maria
    MICROCHEMICAL JOURNAL, 2015, 121 : 192 - 198
  • [6] Determination of lead in a chloride matrix by atomic absorption spectrometry using electrothermal vaporization and capacitively coupled plasma atomization
    Chan, GCY
    Chan, WT
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (03) : 209 - 214
  • [7] Simultaneous determination of As and Sb in soil using hydride generation capacitively coupled plasma microtorch optical emission spectrometry - comparison with inductively coupled plasma optical emission spectrometry
    Frentiu, Tiberiu
    Butaciu, Sinziana
    Ponta, Michaela
    Darvasi, Eugen
    Senila, Marin
    Petreus, Dorin
    Frentiu, Maria
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (10) : 1880 - 1888
  • [8] Determination of Total Mercury in Fish Tissue Using a Low-Cost Cold Vapor Capacitively Coupled Plasma Microtorch Optical Emission Microspectrometer: Comparison with Direct Mercury Determination by Thermal Decomposition Atomic Absorption Spectrometry
    Tiberiu Frentiu
    Sinziana Butaciu
    Michaela Ponta
    Marin Senila
    Eugen Darvasi
    Maria Frentiu
    Dorin Petreus
    Food Analytical Methods, 2015, 8 : 643 - 648
  • [9] Determination of Total Mercury in Fish Tissue Using a Low-Cost Cold Vapor Capacitively Coupled Plasma Microtorch Optical Emission Microspectrometer: Comparison with Direct Mercury Determination by Thermal Decomposition Atomic Absorption Spectrometry
    Frentiu, Tiberiu
    Butaciu, Sinziana
    Ponta, Michaela
    Senila, Marin
    Darvasi, Eugen
    Frentiu, Maria
    Petreus, Dorin
    FOOD ANALYTICAL METHODS, 2015, 8 (03) : 643 - 648
  • [10] Simultaneous determination of As and Sb in soil using hydride generation capacitively coupled plasma microtorch optical emission spectrometry-comparison with inductively coupled plasma optical emission spectrometry
    20143900072302
    Frentiu, Tiberiu, 1880, Royal Society of Chemistry (29):