Fabrication process for integration of SU-8 check valves on printed circuit board- based microfluidic platforms

被引:4
|
作者
Perdigones, Francisco [1 ]
Maria Garcia, Jose [1 ]
Manuel Quero, Jose [1 ]
机构
[1] Univ Seville, Escuela Super Ingn, Dept Ingn Elect, Seville, Spain
关键词
microfluidics; printed circuits; suspensions; microfabrication; SU-8 check valves; printed circuit board; PCB-SU-8 hybrid system; PCB technology; microfluidic platforms; microelectromechanical systems devices;
D O I
10.1049/mnl.2013.0573
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A fabrication process to integrate SU-8 check valves on a microfluidic platform based on a printed circuit board (PCB) is reported. The process allows the fabrication and the integration of these devices with PCB substrates at the same time, thus obtaining a PCB/SU-8 hybrid system with no need of assembly. The SU-8 valves fabricated as proof of concept are composed of four or two suspensions and a plate. The fabrication results confirm the validity of the procedure of the fabrication to build these kinds of microstructures. The behaviour of the valves has experimentally been studied showing good results, demonstrating that the integration of these microelectromechanical systems devices with the PCB technology is compatible.
引用
收藏
页码:37 / 40
页数:4
相关论文
共 20 条
  • [1] DISPERSION OF SU-8 PHOTOLITHOGRAPHY PROCESS FOR FABRICATION OF MICROFLUIDIC DEVICES
    Stanciu, Irina
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES C-ELECTRICAL ENGINEERING AND COMPUTER SCIENCE, 2012, 74 (02): : 127 - 142
  • [2] Characterisation of the fabrication process of freestanding SU-8 microstructures integrated in printing circuit board in microelectromechanical systems
    Perdigones, F.
    Moreno, J. M.
    Luque, A.
    Quero, J. M.
    MICRO & NANO LETTERS, 2010, 5 (01) : 7 - 13
  • [3] SU-8 Micromachining process for Millimeter and Submillimeter-wave Waveguide Circuit Fabrication
    Smith, Charlie H., III
    Barker, N. Scott
    2008 33RD INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER AND TERAHERTZ WAVES, VOLS 1 AND 2, 2008, : 836 - 837
  • [4] Principle and structure of a printed circuit board process-based piezoelectric microfluidic pump integrated into printed circuit board
    Wang, Dai-Hua
    Tang, Lian-Kai
    Peng, Yun-Hao
    Yu, Huai-Qiang
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2019, 30 (17) : 2595 - 2604
  • [5] Fabrication process and characterization of micromechanical sensors based on SU-8 resist
    Jordan, A.
    Buettgenbach, S.
    SMART SENSORS, ACTUATORS, AND MEMS V, 2011, 8066
  • [6] A new fabrication process for ultra-thick microfluidic microstructures utilizing SU-8 photoresist
    Lin, CH
    Lee, GB
    Chang, BW
    Chang, GL
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2002, 12 (05) : 590 - 597
  • [7] Integration method of silicon sensors on SU-8-based microfluidic platforms
    Perdigones, Francisco
    Aracil, Carmen
    Quero, Jose M.
    Gutierrez, Manuel
    Jiménez, Cecilia
    Giménez, Pablo
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2015, 21 (01): : 155 - 161
  • [8] Integration method of silicon sensors on SU-8-based microfluidic platforms
    Francisco Perdigones
    Carmen Aracil
    José M. Quero
    Manuel Gutiérrez
    Cecilia Jiménez
    Pablo Giménez
    Microsystem Technologies, 2015, 21 : 155 - 161
  • [9] Fabrication of a large-scale Ni stamp using a multi-level SU-8 photoresist mold for advanced printed circuit board manufacturing
    Lee, H-S
    Yang, H-H
    Ra, S.
    Yoon, J-B
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2011, 21 (06)
  • [10] Fabrication of an SU-8 based microfluidic reactor on a PEEK substrate sealed by a 'flexible semi-solid transfer' (FST) process
    Song, YJ
    Kumar, CSSR
    Hormes, J
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2004, 14 (07) : 932 - 940