Experimental and numerical studies of acoustical and ventilation performances of glass louver window

被引:2
|
作者
Lee, Hsiao Mun [1 ]
Lim, Kian Meng [1 ]
Lee, Heow Pueh [1 ]
机构
[1] Natl Univ Singapore, Dept Mech Engn, 9 Engn,Dr 1, Singapore 117576, Singapore
基金
新加坡国家研究基金会;
关键词
louver window; noise; ventilation; SYSTEM;
D O I
10.21595/jve.2016.17246
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The noise attenuation and ventilation performances of the glass louver window were investigated using experimental and numerical methods in order to improve the understanding of this common feature in noise mitigation issue. Sound pressure levels (SPLs) data were measured for frequencies ranging from 100 Hz to 6000 Hz for a room fitted with a louver window. It was found that the louver window was able to attenuate 1.4 %, 5.5 % and 12.0 % of the noise when the panels were partially and fully closed at 30 degrees, 60 degrees and 90 degrees, respectively. For frequencies below 3000 Hz, the best attenuation occurred around 1700 Hz to 2000 Hz for all panel angles. The insertion loss (IL) is similar for frequencies ranging from 3000 Hz to 6000 Hz when the louver window was fully closed at 90 degrees. The velocity magnitude of the air passed through the louver panels increased with increased panel angle. The reduction of the mass flow rate for air passed through the louver window when the panels were partially closed at 30 degrees and 60 degrees are 7.7 % and 46.2 %, respectively.
引用
收藏
页码:699 / 706
页数:8
相关论文
共 50 条
  • [1] Experimental study on noise reduction and ventilation performances of sound-proofed ventilation window
    Du, Liangfen
    Lau, Siu-Kit
    Lee, Siew Eang
    Danzer, Martin Konrad
    [J]. BUILDING AND ENVIRONMENT, 2020, 181
  • [2] Acoustical performances of Double Ventilated Glass Facades
    Blasco, M.
    Crispin, C.
    Ingelaere, B.
    [J]. Proceedings of ISMA 2004: International Conference on Noise and Vibration Engineering, Vols 1-8, 2005, : 3635 - 3644
  • [3] Acoustical performances of Ventilated Double Glass Facades
    Blasco, M.
    Crispin, C.
    Ingelaere, B.
    [J]. Research in Building Physics and Building Engineering, 2006, : 287 - 291
  • [4] Experimental and simulation studies on acoustical characterisation of laminated safety glass
    Vedrtnam, Ajitanshu
    Pawar, S. J.
    [J]. GLASS TECHNOLOGY-EUROPEAN JOURNAL OF GLASS SCIENCE AND TECHNOLOGY PART A, 2018, 59 (02): : 58 - 70
  • [5] Numerical evaluation of louver configuration and ventilation strategies for the windcatcher system
    Liu, Shichao
    Mak, C. M.
    Niu, JianLei
    [J]. BUILDING AND ENVIRONMENT, 2011, 46 (08) : 1600 - 1616
  • [6] Experimental and numerical studies on the design of a sonic crystal window
    Lee, Hsiao Mun
    Lim, Kian Meng
    Lee, Heow Pueh
    [J]. JOURNAL OF VIBROENGINEERING, 2017, 19 (03) : 2224 - 2233
  • [8] Numerical prediction of the performances of the fins with punched delta winglets and the louver fins and their comparison
    Min, JC
    Xu, W
    [J]. JOURNAL OF ENHANCED HEAT TRANSFER, 2005, 12 (04) : 357 - 371
  • [9] Louver and window position effect on cross-ventilation in a generic isolated building: A CFD approach
    Yazarlou, Tayyebeh
    Barzkar, Esmaeil
    [J]. INDOOR AND BUILT ENVIRONMENT, 2022, 31 (06) : 1511 - 1529
  • [10] Experimental investigation of thermal and ventilation performances of stratum ventilation
    Tian, Lin
    Lin, Zhang
    Wang, Qiuwang
    [J]. BUILDING AND ENVIRONMENT, 2011, 46 (06) : 1309 - 1320