Single Photon Ionization Orthogonal Acceleration Time-of-Flight Mass Spectrometry and Resonance Enhanced Multiphoton Ionization Time-of-Flight Mass Spectrometry for Evolved Gas Analysis in Thermogravimetry: Comparative Analysis of Crude Oils

被引:46
|
作者
Geissler, Robert [1 ]
Saraji-Bozorgzad, Mohammad R. [1 ]
Groeger, Thomas [1 ]
Fendt, Alois [2 ]
Streibel, Thorsten [2 ]
Sklorz, Martin [2 ]
Krooss, Bernhard M. [3 ]
Fuhrer, Katrin [4 ]
Gonin, Marc [4 ]
Kaisersberger, Erwin [5 ]
Denner, Thomas [5 ]
Zimmermann, Ralf [1 ,2 ,6 ]
机构
[1] Helmholtz Zentrum Munchen, Inst Ecol Chem, D-85764 Neuherberg, Germany
[2] Univ Rostock, Inst Chem, Abt Analyt Techn & Umweltchem, Lehrstuhl Analyt Chem, D-18059 Rostock, Germany
[3] Univ Aachen, Rhein Westfal TH Aachen, Inst Geol & Geochem Petr & Coal, D-52056 Aachen, Germany
[4] Tofwerk AG, CH-3600 Thun, Switzerland
[5] Netzsch Geratebau GmbH, D-95100 Selb, Germany
[6] Bifa Umweltinst GmbH, Kompetenzbereich Chem, D-86167 Augsburg, Germany
关键词
POLYCYCLIC AROMATIC-HYDROCARBONS; THERMAL-DECOMPOSITION; EXCIMER LIGHT; ONLINE; MS; POLYSTYRENE; PYROLYSIS; IDENTIFICATION; DEGRADATION; TEMPERATURE;
D O I
10.1021/ac900216y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Coupling thermal analysis (TA) with a subsequent analytical method in order to investigate evolved gaseous products from the thermal analysis is a well established method. A popular practice to analyze the gaseous products evolving from thermal analysis is mass spectrometry using electron impact ionization (EI).(1-4) As the kinetic energy of the electrons thereby is typically far beyond the ionization energies of the assayed samples, the electron impact effects fragmentation particularly of organic compounds, hampering the correlation of the ion signals to the gaseous compounds. This applies for complex mixtures in particular. Fragmentation can be reduced using so-called soft ionization techniques. In the course of the presented setup, single photon ionization (SPI) using electron beam pumped excimer lamps (EBEL) emitting vacuum ultraviolet (VUV) light (lambda = 126 nm) is employed. For the instrumentation, a TA system has been coupled to an EBEL-SPI-oaTOFMS (oaTOFMS: orthogonal acceleration time-of-flight mass spectrometry) system using a heated transfer capillary in order to detect semivolatile organic substances from the gas flow of a thermobalance with high temporal resolution. Presented measurements focus on crude oils of different origins. In-depth analysis demonstrates that it is possible to tell apart different crude oil samples on the basis of temperature resolved mass spectra gained from the described setup. TA allows for the assay of crude oils without sample preparation via a distillation process which precedes the thermal decomposition of nonvolatile oil components, i.e., resins and asphaltenes. The gases that evolve during thermal analysis are a complex mixture of organic compounds. These can be analyzed without losing molecular information using mass spectrometry with a soft ionization technique, such as SPI.
引用
收藏
页码:6038 / 6048
页数:11
相关论文
共 50 条
  • [1] Desorption/ionization on silicon time-of-flight/time-of-flight mass spectrometry
    Go, EP
    Prenni, JE
    Wei, J
    Jones, A
    Hall, SC
    Witkowska, HE
    Shen, ZX
    Siuzdak, G
    ANALYTICAL CHEMISTRY, 2003, 75 (10) : 2504 - 2506
  • [2] Rapid comprehensive characterization of crude oils by thermogravimetry coupled to fast modulated gas chromatography–single photon ionization time-of-flight mass spectrometry
    S. Wohlfahrt
    M. Fischer
    M. Saraji-Bozorgzad
    G. Matuschek
    T. Streibel
    E. Post
    T. Denner
    R. Zimmermann
    Analytical and Bioanalytical Chemistry, 2013, 405 : 7107 - 7116
  • [3] Orthogonal acceleration time-of-flight mass spectrometry
    Guilhaus, M
    Selby, D
    Mlynski, V
    MASS SPECTROMETRY REVIEWS, 2000, 19 (02) : 65 - 107
  • [4] Gas Chromatography/Femtosecond Multiphoton Ionization/Time-of-Flight Mass Spectrometry of Dioxins
    Watanabe-Ezoe, Yuka
    Li, Xing
    Imasaka, Tomoko
    Uchimura, Tomohiro
    Imasaka, Totaro
    ANALYTICAL CHEMISTRY, 2010, 82 (15) : 6519 - 6525
  • [5] Gas chromatography/multiphoton ionization/time-of-flight mass spectrometry of polychlorinated biphenyls
    Matsui, Taiki
    Uchimura, Tomohiro
    Imasaka, Totaro
    ANALYTICA CHIMICA ACTA, 2011, 694 (1-2) : 108 - 114
  • [6] Multiphoton Ionization Time-of-Flight Mass Spectrometry for the Detection of Bioactive Lignan
    Tomohiro Uchimura
    Goro Tokumoto
    Onon Batnyam
    Chih-Wei Chou
    Satoshi Fujita
    Analytical Sciences, 2016, 32 : 255 - 257
  • [7] A multiphoton ionization study of acetone using time-of-flight mass spectrometry
    ZHENG XianFeng 1
    2 Department of Chemistry
    Science Bulletin, 2010, (Z2) : 3123 - 3130
  • [8] A multiphoton ionization study of acetone using time-of-flight mass spectrometry
    Zheng XianFeng
    Wu HongXia
    Song Yu
    Wu JingZe
    Zhang JingSong
    Cui ZhiFeng
    CHINESE SCIENCE BULLETIN, 2010, 55 (27-28): : 3123 - 3130
  • [9] Multiphoton Ionization Time-of-Flight Mass Spectrometry for the Detection of Bioactive Lignan
    Uchimura, Tomohiro
    Tokumoto, Goro
    Batnyam, Onon
    Chou, Chih-Wei
    Fujita, Satoshi
    ANALYTICAL SCIENCES, 2016, 32 (02) : 255 - 257
  • [10] Rapid comprehensive characterization of crude oils by thermogravimetry coupled to fast modulated gas chromatography-single photon ionization time-of-flight mass spectrometry
    Wohlfahrt, S.
    Fischer, M.
    Saraji-Bozorgzad, M.
    Matuschek, G.
    Streibel, T.
    Post, E.
    Denner, T.
    Zimmermann, R.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (22) : 7107 - 7116