Optically stimulated luminescent glass optical fibre dosemeter

被引:0
|
作者
Huston, AL
Justus, BL
Falkenstein, PL
Miller, RW
Ning, H
Altemus, R
机构
[1] USN, Res Lab, Div Opt Sci, Washington, DC 20375 USA
[2] NCI, Radiat Oncol Branch, Radiat Oncol Sci Program, DCT,NIH, Bethesda, MD 20892 USA
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An optical fibre radiation dosemeter has been developed that utilises optically stimulated luminescence and scintillation to provide independent, remote, real-time dose measurements. The radiation sensitive element consists of a I ifim long, 0.4 turn diameter piece of copper- ion-doped fused quartz that is attached to a 1m length of commercial optical fibre. The dose-meter probe is 0.6 nun in diameter and is flexible enough to be used in standard medical catheters for internal radiation dose measurements. A four-channel dosemeter system has been built and characterised Under conditions typical of a radiotherapy environment. The device exhibits a linear response over the range of doses from 0.01 Gy to 10 Gy. The dosenieter responds identically to both electrons and photons in the range from 4 to 20 MV and the calibration was retained to within +/-2% over a period of 4 weeks. The fibre dosemeter has been used successfully to verify doses received by three patients receiving radiotherapy treatments.
引用
收藏
页码:23 / 26
页数:4
相关论文
共 50 条
  • [1] Optically stimulated luminescent glass optical fibre dosemeter
    Huston, AL
    Justus, BL
    Falkenstein, PL
    Miller, RW
    Ning, H
    Altemus, R
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A23 - A26
  • [2] Optical fibre dosemeter systems for clinical applications based on radioluminescence and optically stimulated luminescence from Al2O3:C
    Marckmann, Carl Johan
    Andersen, Claus E.
    Aznar, Marianne C.
    Botter-Jensen, Lars
    RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) : 28 - 32
  • [3] Household salt as a retrospective dosemeter using optically stimulated luminescence
    Bernhardsson, Christian
    Christiansson, Maria
    Mattsson, Soren
    Raaf, Christopher L.
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2009, 48 (01) : 21 - 28
  • [4] Performance of CVD diamond as an optically and thermally stimulated luminescence dosemeter
    Preciado-Flores, S.
    Schreck, M.
    Melendrez, R.
    Chernov, V.
    Bernal, R.
    Cruz-Vazquez, C.
    Cruz-Zaragoza, E.
    Barboza-Flores, M.
    RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) : 226 - 229
  • [5] Investigation of a BeO-based optically stimulated luminescence dosemeter
    Sommer, M.
    Henniger, J.
    RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) : 394 - 397
  • [6] On optically stimulated luminescence properties of household salt as a retrospective dosemeter
    Timar-Gabor, Alida
    Trandafir, Oana
    RADIATION PROTECTION DOSIMETRY, 2013, 155 (04) : 404 - 409
  • [7] Household salt as a retrospective dosemeter using optically stimulated luminescence
    Christian Bernhardsson
    Maria Christiansson
    Sören Mattsson
    Christopher L. Rääf
    Radiation and Environmental Biophysics, 2009, 48 : 21 - 28
  • [8] Innovational radiation sensor by integrating Al2O3:C optically stimulated luminescent dosemeter and GaN detectors
    Chen, Tai-Chang
    Poochinda, Kunakorn
    Stoebe, Thomas G.
    RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) : 380 - 385
  • [9] A real-time, high-resolution optical fibre dosemeter based on optically stimulated luminescence (OSL) of KBr:Eu, for potential use during the radiotherapy of cancer
    Gaza, R.
    McKeever, S. W. S.
    RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) : 14 - 19
  • [10] Optically Stimulated Luminescence in Beta Irradiated Ge-doped Optical Fibre
    Bradley, D. A.
    Aziz, A. Z.
    Knapton, A. J.
    Abdul-Rashid, H. A.
    Rahman, A. K. M. Mizanur
    Amin, Y. M.
    Nor, R. M.
    Maah, M. J.
    Mahat, R.
    2013 IEEE 4TH INTERNATIONAL CONFERENCE ON PHOTONICS (ICP), 2013, : 38 - 40