Direct electrochemistry and electrocatalysis of hemoglobin in graphene oxide and ionic liquid composite film

被引:40
|
作者
Sun, Wei [1 ]
Gong, Shixing [2 ]
Shi, Fan [1 ]
Cao, Lili [2 ]
Ling, Luyang [2 ]
Zheng, Weizhe [1 ]
Wang, Wencheng [1 ]
机构
[1] Hainan Normal Univ, Coll Chem & Chem Engn, Haikou 571158, Peoples R China
[2] Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Qingdao 266042, Peoples R China
基金
中国国家自然科学基金;
关键词
Hemoglobin; Graphene oxide; Ionic liquid; Carbon ionic liquid electrode; Electrochemistry; DIRECT ELECTRON-TRANSFER; LAYERED DOUBLE HYDROXIDE; GLASSY-CARBON ELECTRODE; MYOGLOBIN; NITRITE; REDUCTION;
D O I
10.1016/j.msec.2014.03.035
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
In this paper a novel sensing platform based on graphene oxide (GO), ionic liquid (IL) 1-ethyl-3-methylimidazolium tetrafluoroborate and Nafion for the immobilization of hemoglobin (Hb) was adopted with a carbon ionic liquid electrode (CILE) as the substrate electrode, which was denoted as Nafion/Hb-GO-IL/CILE. Spectroscopic results suggested that Hb molecules were not denatured in the composite. A pair of well-defined redox peaks appeared on the cyclic voltammogram, which was attributed to the realization of direct electron transfer of Hb on the electrode. Electrochemical behaviors of Hb entrapped in the film were carefully investigated by cyclic voltammetry with the electrochemical parameters calculated. Based on the catalytic ability of the immobilized Hb, Nafion/Hb-GO-IL/CILE exhibited excellent electrocatalytic behavior towards the reduction of different substrates such as trichloroacetic add in the concentration range from 0.01 to 40.0 mM with the detection limit as 3.12 mu Mu (3 sigma), H2O2 in the concentration range from 0.08 to 635.0 mu M with the detection limit as 0.0137 mu M (3 sigma) and NaNO2 in the concentration range from 0.5 to 800.0 mu M with the detection limit as 0.0104 mu M (3 sigma). So the proposed bioelectrode could be served as a new third-generation electrochemical sensor without mediator. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:235 / 241
页数:7
相关论文
共 50 条
  • [1] Direct Electrochemistry and Electrocatalysis of Hemoglobin Immobilized in a Polymeric Ionic Liquid Film
    Zhang, Qian
    Lv, Xue
    Qiao, Yun
    Zhang, Ling
    Liu, Da-Liang
    Zhang, Wei
    Han, Guang-Xi
    Song, Xi-Ming
    [J]. ELECTROANALYSIS, 2010, 22 (09) : 1000 - 1004
  • [2] Direct electrochemistry and electrocatalysis of hemoglobin in composite film based on ionic liquid and NiO microspheres with different morphologies
    Dong, Sheying
    Zhang, Penghui
    Liu, Hui
    Li, Nan
    Huang, Tinglin
    [J]. BIOSENSORS & BIOELECTRONICS, 2011, 26 (10): : 4082 - 4087
  • [3] Direct electrochemistry and electrocatalysis of hemoglobin immobilized into halloysite nanotubes/room temperature ionic liquid composite film
    Zhang, Yang
    Cao, Hongmei
    Fei, Weiwei
    Cui, Daxiang
    Jia, Nengqin
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2012, 162 (01): : 143 - 148
  • [4] Direct electrochemistry and electrocatalysis of hemoglobin protein entrapped in graphene and chitosan composite film
    Xu, Huifeng
    Dai, Hong
    Chen, Guonan
    [J]. TALANTA, 2010, 81 (1-2) : 334 - 338
  • [5] Direct electrochemistry and electrocatalysis of hemoglobin based on poly(diallyldimethylammonium chloride) functionalized graphene sheets/room temperature ionic liquid composite film
    Liu, Kunping
    Zhang, Jingjing
    Yang, Guohai
    Wang, Chunming
    Zhu, Jun-Jie
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2010, 12 (03) : 402 - 405
  • [6] Direct electrochemistry and electrocatalysis of hemoglobin on carbon ionic liquid electrode
    Huang, Ke-Jing
    Sun, Jun-Yong
    Niu, De-Jun
    Xie, Wan-Zhen
    Wang, Wei
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2010, 78 (01) : 69 - 74
  • [7] Application of Cobalt Oxide Nanoflower for Direct Electrochemistry and Electrocatalysis of Hemoglobin with Ionic Liquid as Enhancer
    Zhu, Zhihong
    Li, Xia
    Zeng, Yan
    Sun, Wei
    Zhu, Weiming
    Huang, Xintang
    [J]. JOURNAL OF PHYSICAL CHEMISTRY C, 2011, 115 (25): : 12547 - 12553
  • [8] Direct electrochemistry of hemoglobin based on chitosan-ionic liquid-ferrocene/graphene composite film
    Huang, Ke-Jing
    Miao, Yong-Xia
    Wang, Lan
    Gan, Tian
    Yu, Meng
    Wang, Ling-Ling
    [J]. PROCESS BIOCHEMISTRY, 2012, 47 (07) : 1171 - 1177
  • [9] Direct Electrochemistry and Electrocatalysis of Hemoglobin Immobilized on the Functionalized Graphene-Carbon Nanotube Composite Film
    Wang, Minzhi
    Zheng, Jianbin
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2012, 159 (06) : F150 - F156
  • [10] Direct Electrochemistry and Electrocatalysis of Hemoglobin in Lipid Film Incorporated with Room-Temperature Ionic Liquid
    Li, Gaiping
    Du, Liangwei
    Chen, Hongjun
    Zhang, Lixue
    Wang, Erkang
    [J]. ELECTROANALYSIS, 2008, 20 (20) : 2171 - 2176