Inter-observer variability in target delineation increases during adaptive treatment of head-and-neck and lung cancer

被引:26
|
作者
Apolle, Rudi [1 ,2 ,3 ]
Appold, Steffen [1 ,2 ,4 ,5 ]
Bijl, Henk P. [6 ]
Blanchard, Pierre [7 ]
Bussink, Johan [8 ]
Faivre-Finn, Corinne [9 ]
Khalifa, Jonathan [10 ]
Laprie, Anne [10 ]
Lievens, Yolande [11 ,12 ]
Madani, Indira [13 ]
Ruffier, Amandine [7 ]
de Ruysscher, Dirk [14 ]
van Elmpt, Wouter [14 ]
Troost, Esther G. C. [1 ,2 ,3 ,4 ,5 ,15 ,16 ,17 ,18 ,19 ]
机构
[1] Tech Univ Dresden, Helmholtz Zentrum Dresden Rossendorf, Fac Med, OncoRay Natl Ctr Radiat Res Oncol, Dresden, Germany
[2] Tech Univ Dresden, Helmholtz Zentrum Dresden Rossendorf, Univ Hosp Carl Gustav Carus, Dresden, Germany
[3] Helmholtz Zentrum Dresden Rossendorf, Inst Radiooncol OncoRay, Dresden, Germany
[4] Tech Univ Dresden, Dept Radiotherapy & Radiat Oncol, Fac Med, Dresden, Germany
[5] Tech Univ Dresden, Univ Hosp Carl Gustav Carus, Dresden, Germany
[6] Univ Med Ctr Groningen, Dept Radiat Oncol, Groningen, Netherlands
[7] Gustave Roussy Canc Campus, Dept Radiat Oncol, Villejuif, France
[8] Radboud Univ Nijmegen, Dept Radiat Oncol, Med Ctr, Nijmegen, Netherlands
[9] Univ Manchester, Christie NHS Fdn Trust, Div Canc Sci, Manchester, Lancs, England
[10] Inst Univ Canc Toulouse Oncopole, Dept Radiotherapy, Inst Claudius Regaud, Toulouse, France
[11] Ghent Univ Hosp, Radiat Oncol Dept, Ghent, Belgium
[12] Univ Ghent, Ghent, Belgium
[13] Univ Hosp Zurich, Dept Radiat Oncol, Zurich, Switzerland
[14] Maastricht Univ, Grow Sch Oncol & Dev Biol, Dept Radiat Oncol MAASTRO, Med Ctr, Maastricht, Netherlands
[15] German Canc Consortium DKTK, Partner Site Dresden, Heidelberg, Germany
[16] German Canc Res Ctr, Heidelberg, Germany
[17] Germany German Canc Res Ctr DKFZ, Partner Site Dresden, Natl Ctr Tumor Dis NCT, Heidelberg, Germany
[18] Tech Univ Dresden, Univ Hosp Carl Gustav Carus, Fac Med, Dresden, Germany
[19] Helmholtz Zentrum Dresden Rossendorf, Helmholtz Assoc, Dresden, Germany
关键词
TUMOR VOLUME DELINEATION; SQUAMOUS-CELL CARCINOMA; FDG-PET; CT; RADIOTHERAPY; DEFINITION; LARYNGEAL; HYPOPHARYNGEAL; UNCERTAINTIES; ONCOLOGY;
D O I
10.1080/0284186X.2019.1629017
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: Inter-observer variability (IOV) in target volume delineation is a well-documented source of geometric uncertainty in radiotherapy. Such variability has not yet been explored in the context of adaptive re-delineation based on imaging data acquired during treatment. We compared IOV in the pre- and mid-treatment setting using expert primary gross tumour volume (GTV) and clinical target volume (CTV) delineations in locoregionally advanced head-and-neck squamous cell carcinoma (HNSCC) and (non-)small cell lung cancer [(N)SCLC]. Material and methods: Five and six observers participated in the HNSCC and (N)SCLC arm, respectively, and provided delineations for five cases each. Imaging data consisted of CT studies partly complemented by FDG-PET and was provided in two separate phases for pre- and mid-treatment. Global delineation compatibility was assessed with a volume overlap metric (the Generalised Conformity Index), while local extremes of IOV were identified through the standard deviation of surface distances from observer delineations to a median consensus delineation. Details of delineation procedures, in particular, GTV to CTV expansion and adaptation strategies, were collected through a questionnaire. Results: Volume overlap analysis revealed a worsening of IOV in all but one case per disease site, which failed to reach significance in this small sample (p-value range .063-.125). Changes in agreement were propagated from GTV to CTV delineations, but correlation could not be formally demonstrated. Surface distance based analysis identified longitudinal target extent as a pervasive source of disagreement for HNSCC. High variability in (N)SCLC was often associated with tumours abutting consolidated lung tissue or potentially invading the mediastinum. Adaptation practices were variable between observers with fewer than half stating that they consistently adapted pre-treatment delineations during treatment. Conclusion: IOV in target volume delineation increases during treatment, where a disparity in institutional adaptation practices adds to the conventional causes of IOV. Consensus guidelines are urgently needed.
引用
收藏
页码:1378 / 1385
页数:8
相关论文
共 50 条
  • [1] Inter-observer contouring variations of head-and-neck anatomy
    O'Daniel, JC
    Rosenthal, DI
    Barker, JL
    Ahamad, A
    Asper, JA
    Blanco, AI
    de Crevoisier, R
    Holsinger, FC
    Schwartz, DI
    Ang, KK
    Dong, L
    Garden, AS
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S370 - S370
  • [2] Inter-observer variability in OAR and target volume delineation in curative prostate cancer patients
    Tiigi, K.
    Tiigi, R.
    Oro, I.
    Adamson, M.
    Kolk, K.
    Poldveer, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127
  • [3] Inter-observer variability in target delineation for brain metastases in stereotactic radiotherapy
    Di Biase, S.
    Patani, F.
    Fasciolo, D.
    Rosa, C.
    Di Carlo, C.
    Allajbej, A.
    Gasparini, L.
    Delli Pizzi, A.
    Trignani, M.
    Caravatta, L.
    Genovesi, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S682 - S682
  • [4] Inter-observer variation in target delineation of stage I lung cancer for stereotactic radiotherapy
    Sakamoto, M
    Nagata, Y
    Takayama, K
    Mizowaki, T
    Aoki, T
    Sakamoto, T
    Hiraoka, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S411 - S412
  • [5] Impact of the Intra- and Inter-observer Variability in the Delineation of Parotid Glands on the Dose Calculation During Head and Neck Helical Tomotherapy
    Piotrowski, T.
    Gintowt, K.
    Jodda, A.
    Ryczkowski, A.
    Bandyk, W.
    Bak, B.
    Adamczyk, M.
    Skorska, M.
    Kazmierska, J.
    Malicki, J.
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2015, 14 (04) : 467 - 474
  • [6] Dosimetric consequences of inter-observer planning variability for head/neck radiotherapy
    Lu, L.
    Barani, I. J.
    Cuttino, L.
    Dogan, N.
    Du, W.
    Fatyga, M.
    Siebers, J. V.
    Song, S.
    Wu, Y.
    Murphy, M. J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S449 - S450
  • [7] Inter-observer Variability Analysis of Automatic Lung Delineation in Normal and Disease Patients
    Luca Saba
    Joel C. M. Than
    Norliza M. Noor
    Omar M. Rijal
    Rosminah M. Kassim
    Ashari Yunus
    Chue R. Ng
    Jasjit S. Suri
    [J]. Journal of Medical Systems, 2016, 40
  • [8] Inter-observer Variability Analysis of Automatic Lung Delineation in Normal and Disease Patients
    Saba, Luca
    Than, Joel C. M.
    Noor, Norliza M.
    Rijal, Omar M.
    Kassim, Rosminah M.
    Yunus, Ashari
    Ng, Chue R.
    Suri, Jasjit S.
    [J]. JOURNAL OF MEDICAL SYSTEMS, 2016, 40 (06)
  • [9] Inter-observer variability in MR-based target volume delineation of uveal melanoma
    Klaassen, L.
    Jaarsma-Coes, M. G.
    Verbist, B. M.
    Vu, T. H. K.
    Klaver, Y. L. B.
    Rodrigues, M. F.
    Nabarro, C.
    Luyten, G. P. M.
    Rasch, C. R. N.
    van Herk, M.
    Beenakker, J. W. M.
    [J]. ACTA OPHTHALMOLOGICA, 2022, 100 : 45 - 45
  • [10] Inter-Observer variability in MRI-based target volume delineation of uveal melanoma
    Beenakker, Jan-Willem
    Jaarsma-Coes, Myriam
    Klaassen, Lisa
    Verbist, Berit
    Vu, Khanh
    Klaver, Yvonne
    Rodrigues, Myra
    Nabarro, Claire
    Luyten, Gre
    van Herk, Marcel
    Rasch, Coen
    [J]. ACTA OPHTHALMOLOGICA, 2022, 100