Rapid detection of methicillin resistance in coagulase-negative staphylococci with the VITEK 2 system

被引:14
|
作者
Horstkotte, MA [1 ]
Knobloch, JKM [1 ]
Rohde, H [1 ]
Dobinsky, S [1 ]
Mack, D [1 ]
机构
[1] Univ Hamburg, Klinikum Eppendorf, Inst Med Mikrobiol & Immunol, D-20246 Hamburg, Germany
关键词
D O I
10.1128/JCM.40.9.3291-3295.2002
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The aim of the present study was to evaluate the accuracy of the new VITEK 2 system (bioMerieux, Marcy 1' Etoile, France) for the detection of methicillin resistance in coagulase-negative staphylococci (CoNS) by using AST-P515 and AST-P523 test cards. Analyses of the VITEK 2 oxacillin MIC determination evaluated according to the actual breakpoint ( greater than or equal to0.5 mug/ml) of the National Committee for Clinical Laboratory Standards resulted in a high sensitivity of 99.2% but a moderate specificity of 80%. The newly included oxacillin resistance (OR) test of the VITEK 2 system displayed a high sensitivity and a high specificity of 97.5 and 98.7%, respectively. Concordance between the results of the mecA PCR and the VITEK 2 oxacillin MIC was observed for almost all Staphylococcus epidermidis strains, but the reduced specificity was attributable to higher oxacillin MICs for mecA-negative non-S. epidermidis strains, especially S. saprophyticus, S. lugdunensis, and S. cohnii. Evaluation of alternative oxacillin MIC breakpoints of 1, 2, or 4 mug/ml resulted in improved degrees of specificity of 84, 90.7, and 97.3%, respectively. Only minor changes occurred in the corresponding sensitivity values, which were 98.4, 97.5, and 97.5%, respectively. Methicillin resistance in CoNS was detected after 7 and 8 h in 91.1 and 93.5% of the mecA-positive strains, respectively, by the VITEK 2 OR test and in 86.3 and 89.5% of the mecA-positive strains, respectively, by VITEK 2 oxacillin MIC determination. After 7 and 8 h the VITEK 2 OR test classified 59.2 and 78.9% of the mecA-negative strains, respectively, as susceptible to oxacillin, whereas comparable values were obtained 2 h later by VITEK 2 oxacillin MIC determination. The results of our study encourage the use of the VITEK 2 system, which proved to be a highly reliable and rapid phenotypic method for the detection of methicillin resistance in CoNS.
引用
收藏
页码:3291 / 3295
页数:5
相关论文
共 50 条
  • [1] Detection of Methicillin-Resistant Coagulase-Negative Staphylococci by the Vitek 2 System
    Johnson, Kristen N.
    Andreacchio, Kathleen
    Edelstein, Paul H.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2014, 52 (09) : 3196 - 3199
  • [2] Resistance to Methicillin in Coagulase-negative Staphylococci and Its Detection
    Kolar, Milan
    Bardon, Jan
    Hanulik, Vojtech
    Sauer, Pavel
    Babak, Vladimir
    Schlegelova, Jarmila
    [J]. ACTA VETERINARIA BRNO, 2010, 79 (02) : 261 - 267
  • [3] Rapid detection of the methicillin-resistance gene, mecA, in coagulase-negative Staphylococci
    Glad, T
    Klingenberg, C
    Flægstad, T
    Ericson, JU
    Olsvik, O
    [J]. SCANDINAVIAN JOURNAL OF INFECTIOUS DISEASES, 2001, 33 (07) : 502 - 506
  • [4] Accuracy of the VITEK 2 system to identify coagulase-negative staphylococci
    Saez, A.
    Del Castillo, B. Ruiz
    Aguero, J.
    Martinez-Martinez, L.
    [J]. INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2007, 29 : S488 - S488
  • [5] RAPID DETECTION OF METHICILLIN RESISTANCE IN COAGULASE-NEGATIVE STAPHYLOCOCCI BY COMMERCIALLY AVAILABLE FLUORESCENCE TEST
    IEVEN, M
    JANSENS, H
    URSI, D
    VERHOEVEN, J
    GOOSSENS, H
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (08) : 2183 - 2185
  • [6] Evaluation of different methods for the detection of methicillin resistance in coagulase-negative staphylococci
    Jarlov, JO
    BuschSorensen, C
    Espersen, F
    Mortensen, I
    Hougaard, DM
    Rosdahl, VT
    [J]. JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1997, 40 (02) : 241 - 249
  • [7] THE INFLUENCE OF SALT CONCENTRATION ON THE DETECTION OF METHICILLIN RESISTANCE IN COAGULASE-NEGATIVE STAPHYLOCOCCI
    LAW, D
    MEGSON, GM
    KEANEY, MGL
    GANGULI, LA
    [J]. JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1992, 30 (05) : 603 - 614
  • [8] Evaluation of Moxalactam with the BD phoenix system for detection of methicillin resistance in coagulase-negative staphylococci
    Pupin, H.
    Renaudin, H.
    Join-Lambert, O.
    Bebear, C.
    Megraud, F.
    Lehours, P.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2007, 45 (06) : 2005 - 2008
  • [9] Detection of methicillin resistance in hospital environmental strains of coagulase-negative staphylococci
    Nowak, Tomasz
    Balcerczak, Ewa
    Mirowski, Marek
    Szewczyk, Eligia M.
    [J]. POLISH JOURNAL OF MICROBIOLOGY, 2006, 55 (04) : 339 - 343
  • [10] EFFECTS OF CULTURE MEDIA ON DETECTION OF METHICILLIN RESISTANCE IN COAGULASE-NEGATIVE STAPHYLOCOCCI
    SCOT, RJD
    MORGAN, J
    PETHER, JVS
    JONES, JW
    RICHARDSON, JF
    BOSLEY, RHF