Functional and radiological outcomes after treatment with custom-made acetabular components in patients with Paprosky type 3 acetabular defects: short-term results

被引:7
|
作者
Gruber, Michael S. [1 ]
Jesenko, Michael [2 ]
Burghuber, Julia [1 ]
Hochreiter, Josef [3 ]
Ritschl, Peter [2 ]
Ortmaier, Reinhold [3 ,4 ,5 ]
机构
[1] Unfallkrankenhaus Linz, A-4020 Linz, Upper Austria, Austria
[2] Orthoped Hosp Gersthof, A-1180 Vienna, Austria
[3] Paracelsus Med Univ Salzburg, Ordensklinikum Barmherzige Schwestern Linz, Teaching Hosp, Dept Orthoped Surg,Vinzenzgrp Ctr Orthoped Excell, A-4020 Linz, Austria
[4] Tirol Kliniken GmbH, Inst Sports Med Alpine Med & Hlth Tourism ISAG, Innsbruck, Austria
[5] UMIT, Hall Austria, A-6020 Innsbruck, Tyrol, Austria
关键词
CTAC; 3D-printed prosthesis; Revision surgery; Severe acetabular bone loss; Custom-made acetabular component; Total hip arthroplasty; TOTAL HIP-ARTHROPLASTY; REVISION ARTHROPLASTY; CLASSIFICATION;
D O I
10.1186/s12891-020-03851-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundSevere acetabular defects require special treatment with either impaction bone grafting, metal augmented cups or cup-cage constructs. Even these options are often not adequate, especially in hips with Paprosky type 3 defects with loss of anterior and posterior columns. This study investigates the clinical and radiological outcomes of custom-made acetabular components ((c) Materialise NV, Leuven, Belgium) for Paprosky type 3 defects.MethodsSixteen patients were eligible for this trial, nine of whom agreed to be included. All of them completed one year of follow-up. The Harris hip score and the Oxford hip score were used to compare pre- and postoperative functional outcomes. Radiological follow-up comprised anteversion and inclination of the implanted cup and offset measurements in both hips (femoral, medial, ischial offset and center of rotation). Statistical analyses were performed with IBM SPSS Statistics.ResultsThe mean follow-up time of the nine patients was 12.2months (range: 10-18). The Oxford hip score and Harris hip score improved from 19.8 and 50.1 to 29.4 and 68.8, respectively (p=0.009 and 0.01). There were complications in three cases (33.3%), which led to one re-revision (11.1%). Radiologic follow-up showed restoration of the height of the center of rotation and of the global offset. Significant difference was detected in the femoral offset.ConclusionsThe functional and radiological outcomes are promising. However, long-term outcomes still need to be examined.Level of evidenceTherapeutic Level IV.
引用
收藏
页数:8
相关论文
共 24 条
  • [1] Functional and radiological outcomes after treatment with custom-made acetabular components in patients with Paprosky type 3 acetabular defects: short-term results
    Michael S. Gruber
    Michael Jesenko
    Julia Burghuber
    Josef Hochreiter
    Peter Ritschl
    Reinhold Ortmaier
    [J]. BMC Musculoskeletal Disorders, 21
  • [2] A Custom-made Acetabular Implant for Paprosky Type 3 Defects
    Baauw, Marieke
    van Hellemondt, Gijs Gerard
    Spruit, Maarten
    [J]. ORTHOPEDICS, 2017, 40 (01) : E195 - E198
  • [3] Custom-made triflanged acetabular components in the treatment of major acetabular defects. Short-term results and clinical experience
    Myncke, Irisa
    van Schaik, David
    Scheerlinck, Thierry
    [J]. ACTA ORTHOPAEDICA BELGICA, 2017, 83 (03): : 341 - 350
  • [4] Management of Paprosky type three B acetabular defects by custom-made components: early results
    Alessandro Aprato
    Matteo Giachino
    Paolo Bedino
    Danilo Mellano
    Raimondo Piana
    Alessandro Massè
    [J]. International Orthopaedics, 2019, 43 : 117 - 122
  • [5] Management of Paprosky type three B acetabular defects by custom-made components: early results
    Aprato, Alessandro
    Giachino, Matteo
    Bedino, Paolo
    Mellano, Danilo
    Piana, Raimondo
    Masse, Alessandro
    [J]. INTERNATIONAL ORTHOPAEDICS, 2019, 43 (01) : 117 - 122
  • [6] Custom Made Monoflange Acetabular Components for the Treatment of Paprosky Type III Defects
    von Hertzberg-Boelch, Sebastian Philipp
    Wagenbrenner, Mike
    Arnholdt, Joerg
    Frenzel, Stephan
    Holzapfel, Boris Michael
    Rudert, Maximilian
    [J]. JOURNAL OF PERSONALIZED MEDICINE, 2021, 11 (04):
  • [7] Mid-term results after revision total hip arthroplasty with custom-made acetabular implants in patients with Paprosky III acetabular bone loss
    F. S. Fröschen
    T. M. Randau
    G. T. R. Hischebeth
    N. Gravius
    S. Gravius
    S. G. Walter
    [J]. Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 263 - 273
  • [8] Mid-term results after revision total hip arthroplasty with custom-made acetabular implants in patients with Paprosky III acetabular bone loss
    Froeschen, F. S.
    Randau, T. M.
    Hischebeth, G. T. R.
    Gravius, N.
    Gravius, S.
    Walter, S. G.
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (02) : 263 - 273
  • [9] Reconstruction of Paprosky III defects with custom-made implants: do we get them in the correct position? SHORT-TERM RADIOLOGICAL RESULTS
    Wessling, M.
    Gebert, C.
    Hakenes, T.
    Dudda, M.
    Hardes, J.
    Frieler, S.
    Jeys, L. M.
    Hanusrichter, Y.
    [J]. BONE & JOINT JOURNAL, 2022, 104B (10): : 1110 - 1117
  • [10] Custom-made 3D-printed porous metal acetabular composite component in revision hip arthroplasty with Paprosky type III acetabular defects: A case report
    Xiao, Cong
    Zhang, Shaoyun
    Gao, Zhixiang
    Tu, Chongqi
    [J]. TECHNOLOGY AND HEALTH CARE, 2023, 31 (01) : 283 - 291