Robust Signal Synthesis of the 12-Lead ECG using 3-Lead Wireless ECG Systems

被引:0
|
作者
Hsu, Chih-Hao [1 ]
Wu, Sau-Hsuan [1 ]
机构
[1] Natl Chiao Tung Univ, Dept Elect & Comp Engn, Hsinchu, Taiwan
关键词
D O I
暂无
中图分类号
TN [电子技术、通信技术];
学科分类号
0809 ;
摘要
A new signal synthesis and tracking method is developed for a 3-Lead wireless electrocardiography (ECG) system. Exploiting the temporal correlations in ECG signals, the standard 12-lead ECG signals can be synthesized with high precision by using only three differential pairs of electrodes. The correlations between the original and synthesized ECG leads can be as high as 0.98. And the separation between the two electrodes of a pair can be drastically reduced to around 10 cm, which is about the size of a medium adhesive tape. Experiment results also show that the proposed ECG synthesis method is much more robust to variations in acquisition positions when taking into account the spatial correlations among the ECG leads in syntheses. This greatly improves the feasibility of using fully wireless ECG systems on the long-term monitoring and diagnosis of heart diseases.
引用
收藏
页码:3517 / 3522
页数:6
相关论文
共 50 条
  • [1] CORRELATION OF CLINICAL INFORMATION IN STANDARD 12-LEAD ECG AND IN A CORRECTED ORTHOGONAL 3-LEAD ECG
    PIPBERGER, H
    PERLOFF, JK
    BIALEK, SM
    SCHNAPER, HW
    [J]. AMERICAN HEART JOURNAL, 1961, 61 (01) : 34 - &
  • [2] Validation of the 3-lead tele-ECG versus the 12-lead tele-ECG and the conventional 12-lead ECG method in older people
    Antonicelli, Roberto
    Ripa, Chiara
    Abbatecola, Angela M.
    Capparuccia, Carlo A.
    Ferrara, Letizia
    Spazzafumo, Liana
    [J]. JOURNAL OF TELEMEDICINE AND TELECARE, 2012, 18 (02) : 104 - 108
  • [3] Derived 12-lead ECG systems
    Nelwan, SP
    Meij, SH
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2006, 39 (01) : 29 - 30
  • [4] A novel method based on convolutional neural networks for deriving standard 12-lead ECG from serial 3-lead ECG
    Lu-di Wang
    Wei Zhou
    Ying Xing
    Na Liu
    Mahmood Movahedipour
    Xiao-guang Zhou
    [J]. Frontiers of Information Technology & Electronic Engineering, 2019, 20 : 405 - 413
  • [5] A novel method based on convolutional neural networks for deriving standard 12-lead ECG from serial 3-lead ECG
    Wang, Lu-di
    Zhou, Wei
    Xing, Ying
    Liu, Na
    Movahedipour, Mahmood
    Zhou, Xiao-guang
    [J]. FRONTIERS OF INFORMATION TECHNOLOGY & ELECTRONIC ENGINEERING, 2019, 20 (03) : 405 - 413
  • [6] A novel method based on convolutional neural networks for deriving standard 12-lead ECG from serial 3-lead ECG
    Lu-di WANG
    Wei ZHOU
    Ying XING
    Na LIU
    Mahmood MOVAHEDIPOUR
    Xiao-guang ZHOU
    [J]. Frontiers of Information Technology & Electronic Engineering, 2019, 20 (03) : 405 - 413
  • [7] Accurate and reliable 3-lead to 12-lead ECG reconstruction methodology for remote health monitoring applications
    Maheshwari, S.
    Acharyya, A.
    Rajalakshmi, P.
    Puddu, P. E.
    Schiariti, M.
    [J]. IRBM, 2014, 35 (06) : 341 - 350
  • [8] Erratum to: A novel method based on convolutional neural networks for deriving standard 12-lead ECG from serial 3-lead ECG
    Lu-di Wang
    Wei Zhou
    Ying Xing
    Na Liu
    Mahmood Movahedipour
    Xiao-guang Zhou
    [J]. Frontiers of Information Technology & Electronic Engineering, 2019, 20 : 750 - 750
  • [9] Prehospital 12-lead ECG
    Joyce, SM
    [J]. ANNALS OF EMERGENCY MEDICINE, 1997, 30 (03) : 352 - 352
  • [10] PREHOSPITAL 12-LEAD ECG
    WHITE, RD
    [J]. ANNALS OF EMERGENCY MEDICINE, 1992, 21 (05) : 586 - 586