Influence of ventilation structure on air flow distribution of large turbo-generator

被引:1
|
作者
Zhang, Liying [1 ]
Ding, Shuye [2 ]
Zhao, Zhijun [1 ]
Yang, Jingmo [1 ]
机构
[1] Harbin Univ Sci & Technol, Harbin, Heilongjiang, Peoples R China
[2] Nanjing Normal Univ, Nanjing, Jiangsu, Peoples R China
关键词
Air cooling Turbo generator; ventilation structure; distribution of air; comparison and analysis;
D O I
10.1063/1.5033631
中图分类号
O59 [应用物理学];
学科分类号
摘要
For the 350 MW air - cooled turbo generator; the rotor body is ventilated by sub -slots and 94 radial ventilation ducts and the end adopts arc segment and the straight section to acquire the wind. The stator is ventilated with five inlets and eight outlet air branches. In order to analyze the cooling effect of different ventilation schemes, a global physical model including the stator, rotor; casing and fan is established, and the assumptions and boundary conditions of the solution domain are given, the finite volume method is used to solve the problem, and the air flow distribution characteristics of each part of the motor under different ventilation schemes are obtained. The results show that the baffle at the end of the rotor can eliminate the eddy current at the end of the rotor, and make the flow distribution of cooling air more uniform and reasonable. The conclusions can provide reference for the design of motor ventilation structure.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Influence of Large Turbo-Generator Stator Ventilation Ducts Structural Changes on Stator Temperature
    Huo, Feiyang
    Sun, Jiahui
    Li, Weili
    Zhang, Yihuang
    [J]. MATERIAL SCIENCE AND ENGINEERING TECHNOLOGY, 2012, 462 : 318 - +
  • [2] Influence of a Novel Stator Teeth Internal Ventilation Structure on Air-Cooled Turbo-Generator Parameters and Stator Temperature
    Liu, Wenmao
    Li, Weili
    Luo, Shifan
    Huang, Xuelian
    Li, Dan
    Li, Zhiqiang
    Xu, Guorui
    [J]. IEEE ACCESS, 2020, 8 : 122422 - 122433
  • [3] Numerical Studies on the Flow Field of Stator and Air Gap for Large Air-cooled Turbo-generator
    Han, Jiade
    Hong, Guangyu
    Tang, Lu
    Lu, Yiping
    [J]. ELECTRICAL POWER & ENERGY SYSTEMS, PTS 1 AND 2, 2012, 516-517 : 970 - 975
  • [4] Calculation and analysis of fluid flow and heat transfer of air-cooled turbo-generator with multipath ventilation
    Li, Weili
    Yang, Xuefeng
    Gu, Debao
    Feng, Yongli
    [J]. Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2009, 24 (12): : 24 - 31
  • [5] Sensitivity of Axial Velocity at the Air Gap Entrance to Flow Rate Distribution at Stator Radial Ventilation Ducts of Air-Cooled Turbo-Generator with Single-Channel Ventilation
    Li, Yong
    Li, Weili
    Su, Ying
    [J]. ENERGIES, 2019, 12 (18)
  • [6] Flow field analysis of new type ventilation method in one air-cooled turbo-generator rotor
    Lu, Yi-Ping
    Chen, Peng-Fei
    Li, Jun-Ting
    Zhang, Xin
    Deng, Hai-Yan
    Han, Jia-De
    [J]. Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (06): : 63 - 68
  • [7] Research on Relativity of Flow Rate Distribution Inside the Rotor Domain for a Large-Scale Air-Cooled Turbo-Generator
    Ding, Shuye
    Jiang, Xin
    Li, Zhenjiang
    Li, Zhenghui
    [J]. IEEE ACCESS, 2019, 7 : 174889 - 174897
  • [8] Numerical Simulation of the Flow Field for Rotor Ventilation System of Large-scale Nuclear Power Turbo-Generator
    Zhang Xiaohu
    Hu Lei
    Yuan Jianhua
    Yuan Yichao
    [J]. MECHANICAL ENGINEERING AND MATERIALS, PTS 1-3, 2012, 152-154 : 1498 - +
  • [9] Influence of rotor magnetic circuit structure on synchronous reactance of turbo-generator
    [J]. Liang, Y.-P., 1600, Editorial Department of Electric Machines and Control (17):
  • [10] Temperature field of one air-cooled turbo-generator rotor with new ventilation type
    Lu, Yiping
    Chen, Pengfei
    Deng, Haiyan
    Han, Jiade
    [J]. Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2010, 25 (11): : 29 - 35