Image distortion correction in fMRI: A quantitative evaluation

被引:518
|
作者
Hutton, C [1 ]
Bork, A [1 ]
Josephs, O [1 ]
Deichmann, R [1 ]
Ashburner, J [1 ]
Turner, R [1 ]
机构
[1] Inst Neurol, Wellcome Dept Cognit Neurol, London WC1N 3BG, England
基金
英国惠康基金;
关键词
D O I
10.1006/nimg.2001.1054
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
A well-recognized problem with the echo-planar imaging (EPI) technique most commonly used for functional magnetic resonance imaging (fMRI) studies is geometric distortion caused by magnetic field inhomogeneity. This makes it difficult to achieve an accurate registration between a functional activation map calculated from an EPI time series and an undistorted, high resolution anatomical image. A correction method based on mapping the spatial distribution of field inhomogeneities can be used to reduce these distortions. This approach is attractive in its simplicity but requires post-processing to improve the robustness of the acquired field map and reduce any secondary artifacts. Furthermore, the distribution of the internal magnetic field throughout the head is position dependent resulting in an interaction between distortion and head motion. Therefore, a single field map may not be sufficient to correct for the distortions throughout a whole fMRI time series. In this paper we present a quantitative evaluation of image distortion correction for fMRI at 2T. We assess W methods for the acquisition and calculation of field maps, (ii) the effect of image distortion correction on the coregistration between anatomical and functional images, and (iii) the interaction between distortion and head motion, assessing the feasibility of using field maps to reduce this effect. We propose that field maps with acceptable noise levels can be generated easily using a dual echo-time EPI sequence and demonstrate the importance of distortion correction for anatomical coregistration, even for small distortions. Using a dual echo-time series to generate a unique field map at each time point, we characterize the interaction between head motion and geometric distortion. However, we suggest that the variance between successively measured field maps introduces additional unwanted variance in the voxel time-series and is therefore not adequate to correct for time-varying distortions. (C) 2002 Elsevier Science (USA).
引用
收藏
页码:217 / 240
页数:24
相关论文
共 50 条
  • [1] Quantitative evaluation of image-based distortion correction in diffusion tensor imaging
    Netsch, T
    van Muiswinkel, A
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (07) : 789 - 798
  • [2] Correction of geometric distortion in fMRI data
    Jezzard, Peter
    [J]. NEUROIMAGE, 2012, 62 (02) : 648 - 651
  • [3] Dynamic field mapping and distortion correction for fMRI
    Xu, Ning
    Fitzpatrick, J. Michael
    [J]. MEDICAL IMAGING 2007: IMAGE PROCESSING, PTS 1-3, 2007, 6512
  • [4] Quantitative Evaluation of the MRI Image Distortion in Gamma Knife Radiosurgery
    Feng, W.
    Xu, Y.
    Burri, R.
    Chen, H.
    Wuu, C.
    Isaacson, S.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [5] IMAGE INTENSIFIER DISTORTION CORRECTION
    CHAKRABORTY, DP
    [J]. MEDICAL PHYSICS, 1987, 14 (02) : 249 - 252
  • [6] Differential image distortion correction
    Pollak, C
    Stubbings, T
    Hutter, H
    [J]. MICROSCOPY AND MICROANALYSIS, 2001, 7 (04) : 335 - 340
  • [7] The effects of geometric distortion correction on motion realignment in fMRI
    Elliott, MA
    Gualtieri, EE
    Hulvershorn, J
    Ragland, JD
    Gur, R
    [J]. ACADEMIC RADIOLOGY, 2004, 11 (09) : 1005 - 1010
  • [8] Geometric Distortion Correction to Testing Image
    Zhang, Fangzhou
    Zuo, Xiaoyan
    Liu, Jiafa
    Wu, Xiaoyu
    Wang, Yan
    [J]. PIAGENG 2009: IMAGE PROCESSING AND PHOTONICS FOR AGRICULTURAL ENGINEERING, 2009, 7489
  • [9] The clinical relevance of distortion correction in presurgical fMRI at 7 T
    Cardoso, Pedro Lima
    Dymerska, Barbara
    Bachrata, Beata
    Fischmeister, Florian Ph. S.
    Mahr, Nina
    Matt, Eva
    Trattnig, Siegfried
    Beisteiner, Roland
    Robinson, Simon Daniel
    [J]. NEUROIMAGE, 2018, 168 : 490 - 498
  • [10] Evaluation of EPI distortion correction methods for quantitative MRI of the brain at high magnetic field
    Hong, Xin
    Xuan Vinh To
    Teh, Irvin
    Soh, Jian Rui
    Chuang, Kai-Hsiang
    [J]. MAGNETIC RESONANCE IMAGING, 2015, 33 (09) : 1098 - 1105