PURPOSE. To investigate the magnification characteristic of the +90-D double-aspheric fundus examination lens for biomicroscopic measurement of the optic disc. METHODS. A calibrated Gullstrand-type model eye adjusted for axial ametropia between -12.5 and +12.6 D was used to measure the change in magnification of the system with refractive error and variation in fundus lens position. A correction factor p (in degrees per millimeter) at different axial ametropias was also calculated. RESULTS. The total change in magnification of the system from myopia to hyperopia was -15.1% to +13.7%. When the fundus lens position was altered with respect to the model eye by +/-1-2 mm under myopic conditions, the change in magnification of the system was -4.8% to +8.1%. In the hyperopic condition the change was -4.8% to +6.0%. The fundus lens exhibited a linear relationship between p and the degree of ametropia of the model eye and a constant relationship between p and ametropia of -5 to +5 D. CONCLUSIONS. Axial ametropia has a significant effect on biomicroscopic measurement of the optic disc with the +90-D lens. Therefore, a correction factor (p) was calculated that can be used in calculations for determining true optic disc size. These findings may be important for improving clinical disc biometry.
引用
收藏
页码:1817 / 1819
页数:3
相关论文
共 8 条
  • [1] BIOMICROSCOPIC EXAMINATION OF THE OCULAR FUNDUS WITH THE USE OF A +90 DIOPTER LENS
    BRASSEUR, G
    MEHECH, M
    CHARLIN, JF
    RETOUT, A
    [J]. JOURNAL FRANCAIS D OPHTALMOLOGIE, 1989, 12 (03): : 227 - 232
  • [2] BIOMICROSCOPIC EXAMINATION OF THE OCULAR FUNDUS WITH A + 150 DIOPTER LENS
    LEE, NB
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1990, 74 (05) : 294 - 296
  • [3] BIOMICROSCOPIC EXAMINATION OF THE OCULAR FUNDUS WITH A +60-DIOPTER LENS
    LUNDBERG, C
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1985, 99 (04) : 490 - 491
  • [4] VITREOUS PHOTOGRAPHY WITH A +90-DIOPTER DOUBLE ASPHERIC PRESET LENS VS THE ELBAYADI-KAJIURA PRESET LENS
    KAKEHASHI, A
    AKIBA, J
    TREMPE, CL
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1991, 109 (07) : 962 - 965
  • [5] Prediction of profile deviation during glass molding of double-aspheric lens
    Kejun, Zhu
    Sheng, Shi
    Zhigang, Chen
    Zhihui, Liu
    Yingying, Zhang
    [J]. Journal of Engineering Science and Technology Review, 2020, 13 (02) : 50 - 56
  • [6] A COMPARISON OF FUNDUS BIOMICROSCOPY AND 90 DIOPTER LENS EXAMINATION IN THE DETECTION OF DIABETIC CLINICALLY SIGNIFICANT MACULAR EDEMA
    BRUN, SC
    BRESSLER, SB
    MAGUIRE, MG
    HEINER, C
    BRESSLER, NM
    SCHACHAT, AP
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 718 - 718
  • [7] Multichannel laser diode to polymer waveguide array coupling with a double-aspheric lens
    Kunze, K.
    Gossler, C.
    Reinhardt, M.
    Arnold, M.
    Schwenzer, F.
    Helke, C.
    Reuter, D.
    Keppeler, D.
    Moser, T.
    Schwarz, U. T.
    [J]. APPLIED OPTICS, 2023, 62 (35) : 9353 - 9360
  • [8] Do-it-yourself adapter for fundus examination with 90D and 78D lens
    Fogla, Rajesh
    Gujar, Prateek
    Law, Michael
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (02) : 653 - 654