Skin Impedance Measurements with Nanomesh Electrodes for Monitoring Skin Hydration

被引:52
|
作者
Matsukawa, Ryotaro [1 ]
Miyamoto, Akihito [1 ]
Yokota, Tomoyuki [1 ]
Someya, Takao [1 ]
机构
[1] Univ Tokyo, Sch Engn, Dept Elect Engn & Informat Syst, Bunkyo Ku, 7-3-1 Hongo, Tokyo 1138656, Japan
基金
日本学术振兴会;
关键词
hydration monitoring; nanomesh electrodes; wearable electronics; SEVERITY;
D O I
10.1002/adhm.202001322
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The importance of continuous monitoring of skin hydration in daily life, to aid in the diagnosis of skin diseases, is rising. Electrodes that can be worn directly on the skin are attracting attention as an effective means. However, they should not inhibit natural water evaporation from the skin and should not cause inflammation or irritation even if they are attached to the body for long periods of time. In this study, nanomesh electrodes that have previously been reported to exhibit high biocompatibility are also found to exhibit high water vapor permeability, resulting in properties that prevent skin dampness. Furthermore, the skin impedance measured using nanomesh electrodes is found to correlate with the hydration level of skin measured using existing medical equipment. This study provides a new approach to measure skin hydration in conditions close to bare skin.
引用
下载
收藏
页数:6
相关论文
共 50 条
  • [1] IMPEDANCE MEASUREMENTS FOR THE NON-INVASIVE MONITORING OF SKIN HYDRATION - A REASSESSMENT
    KOHLI, R
    ARCHER, WI
    ROBERTS, JMC
    COCHRAN, AJ
    PO, ALW
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1985, 26 (03) : 275 - 287
  • [2] SKIN IMPEDANCE MEASUREMENTS USING SIMPLE AND COMPOUND ELECTRODES
    WOO, EJ
    HUA, P
    WEBSTER, JG
    TOMPKINS, WJ
    PALLASARENY, R
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (01) : 97 - 102
  • [3] Epidermal Differential Impedance Sensor for Conformal Skin Hydration Monitoring
    Huang, Xian
    Yeo, Woon-Hong
    Liu, Yuhao
    Rogers, John A.
    BIOINTERPHASES, 2012, 7 (1-4) : 1 - 9
  • [4] Highly Precise, Continuous, Long-Term Monitoring of Skin Electrical Resistance by Nanomesh Electrodes
    Miyamoto, Akihito
    Kawasaki, Hiroshi
    Lee, Sunghoon
    Yokota, Tomoyuki
    Amagai, Masayuki
    Someya, Takao
    ADVANCED HEALTHCARE MATERIALS, 2022, 11 (10)
  • [5] Calibration of skin hydration measurements
    Martinsen, O. G.
    Grimnes, S.
    Nilsen, J. K.
    Tronstad, C.
    Jang, W.
    Kim, H.
    Shin, K.
    13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 161 - +
  • [6] Printed soft skin electrodes for seamless bio-impedance measurements
    Levit, Bara
    Krebsbach, Peter
    Bar-Haim, Chen
    Hernandez-Sosa, Gerardo
    Hanein, Yael
    FLEXIBLE AND PRINTED ELECTRONICS, 2023, 8 (01):
  • [7] Monitoring of rat skin flap ischemia by bioelectrical impedance measurements
    Islamoglu, K
    Ozgentas, E
    ANNALS OF PLASTIC SURGERY, 2001, 47 (05) : 534 - 539
  • [8] INTERPRETATION OF SKIN IMPEDANCE MEASUREMENTS
    TREGEAR, RT
    NATURE, 1965, 205 (4971) : 600 - &
  • [9] Dependence of Skin-Electrode Contact Impedance on Material and Skin Hydration
    Goyal, Krittika
    Borkholder, David A.
    Day, Steven W.
    SENSORS, 2022, 22 (21)
  • [10] OBSERVATIONS OF INFLUENCE OF ELECTRODES ON SKIN IMPEDANCE
    BERNARDI, L
    VIGNINI, M
    FOGARI, R
    CERIMELE, D
    GIORNALE ITALIANO DI DERMATOLOGIA MINERVA DERMATOLOGICA, 1977, 112 (04): : 283 - 286