Three-dimensional liver motion tracking using real-time two-dimensional MRI

被引:61
|
作者
Brix, Lau [1 ,2 ]
Ringgaard, Steffen [2 ]
Sorensen, Thomas Sangild [3 ,4 ]
Poulsen, Per Rugaard [4 ,5 ]
机构
[1] Reg Midt, Dept Procurement & Clin Engn, DK-8200 Aarhus N, Denmark
[2] Aarhus Univ Hosp, MR Res Ctr, DK-8200 Aarhus N, Denmark
[3] Aarhus Univ, Dept Comp Sci, DK-8200 Aarhus N, Denmark
[4] Aarhus Univ, Dept Clin Med, DK-8200 Aarhus N, Denmark
[5] Aarhus Univ Hosp, Dept Oncol, DK-8000 Aarhus C, Denmark
关键词
MR-Linac; real-time MRI; organ motion; vessel tracking; MRI; LUNG MOTION; RADIOTHERAPY; TUMORS; REPRODUCIBILITY; RECONSTRUCTION; MOVEMENT;
D O I
10.1118/1.4867859
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Combined magnetic resonance imaging (MRI) systems and linear accelerators for radiotherapy (MR-Linacs) are currently under development. MRI is noninvasive and nonionizing and can produce images with high soft tissue contrast. However, new tracking methods are required to obtain fast real-time spatial target localization. This study develops and evaluates a method for tracking three-dimensional (3D) respiratory liver motion in two-dimensional (2D) real-time MRI image series with high temporal and spatial resolution. Methods: The proposed method for 3D tracking in 2D real-time MRI series has three steps: (1) Recording of a 3D MRI scan and selection of a blood vessel (or tumor) structure to be tracked in subsequent 2D MRI series. (2) Generation of a library of 2D image templates oriented parallel to the 2D MRI image series by reslicing and resampling the 3D MRI scan. (3) 3D tracking of the selected structure in each real-time 2D image by finding the template and template position that yield the highest normalized cross correlation coefficient with the image. Since the tracked structure has a known 3D position relative to each template, the selection and 2D localization of a specific template translates into quantification of both the through-plane and in-plane position of the structure. As a proof of principle, 3D tracking of liver blood vessel structures was performed in five healthy volunteers in two 5.4 Hz axial, sagittal, and coronal real-time 2D MRI series of 30 s duration. In each 2D MRI series, the 3D localization was carried out twice, using nonoverlapping template libraries, which resulted in a total of 12 estimated 3D trajectories per volunteer. Validation tests carried out to support the tracking algorithm included quantification of the breathing induced 3D liver motion and liver motion directionality for the volunteers, and comparison of 2D MRI estimated positions of a structure in a watermelon with the actual positions. Results: Axial, sagittal, and coronal 2D MRI series yielded 3D respiratory motion curves for all volunteers. The motion directionality and amplitude were very similar when measured directly as in-plane motion or estimated indirectly as through-plane motion. The mean peak-to-peak breathing amplitude was 1.6 mm (left-right), 11.0 mm (craniocaudal), and 2.5 mm (anterior-posterior). The position of the watermelon structure was estimated in 2D MRI images with a root-mean-square error of 0.52 mm (in-plane) and 0.87 mm (through-plane). Conclusions: A method for 3D tracking in 2D MRI series was developed and demonstrated for liver tracking in volunteers. The method would allow real-time 3D localization with integrated MR-Linac systems. (c) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Three-dimensional liver motion tracking using 2D real-time MRI
    Brix, L.
    Ringgaard, S.
    Sorensen, T. Sangild
    Poulsen, P. Rugaard
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S86 - S86
  • [2] Real-Time Three-Dimensional Flexible Needle Tracking using Two-Dimensional Ultrasound
    Vrooijink, Gustaaf J.
    Abayazid, Momen
    Misra, Sarthak
    [J]. 2013 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2013, : 1688 - 1693
  • [3] Automated tracking of mitral annular motion using two-dimensional echocardiography for evaluation of left ventricular function: A comparison with real-time three-dimensional echocardiography
    Eto, Y
    Shiota, T
    Yamada, H
    Qin, JX
    Tsujino, H
    Agler, DA
    Shin, JH
    Saracino, G
    Greenberg, NL
    Thomas, JD
    [J]. CIRCULATION, 2002, 106 (19) : 507 - 507
  • [4] Evaluation of left ventricular rotation by two-dimensional speckle tracking method and real-time three-dimensional echocardiography: Comparison with MRI tagging method
    Hayashi H.
    Izumi C.
    Takahashi S.
    Uchikoshi M.
    Yamazaki R.
    Asanuma T.
    Ishikura F.
    Beppu S.
    Nakatani S.
    [J]. Journal of Echocardiography, 2011, 9 (3) : 83 - 89
  • [5] Management of three-dimensional intrafraction motion through real-time DMLC tracking
    Sawant, Amit
    Venkat, Raghu
    Srivastava, Vikram
    Carlson, David
    Povzner, Sergey
    Cattell, Herb
    Keall, Paul
    [J]. MEDICAL PHYSICS, 2008, 35 (05) : 2050 - 2061
  • [6] Real-Time Monocular Three-Dimensional Motion Tracking Using a Multithread Active Vision System
    Hu, Shaopeng
    Jiang, Mingjun
    Takaki, Takeshi
    Ishii, Idaku
    [J]. JOURNAL OF ROBOTICS AND MECHATRONICS, 2018, 30 (03) : 453 - 466
  • [7] Three-Dimensional Tracking of an Aircraft Using Two-Dimensional Radars
    Mallick, Mahendra
    Arulampalam, Sanjeev
    Yan, Yanjun
    Ru, Jifeng
    [J]. IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 2018, 54 (02) : 585 - 600
  • [8] Real-time visualization of arbitrary two-dimensional sections from three-dimensional acquisition
    Capineri, L
    Masotti, L
    Rocchi, S
    Andreuccetti, F
    Cerofolini, M
    Tondini, A
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (03): : 319 - 328
  • [9] Real-time Three-dimensional Tracking of Endocytic Vesicles
    Duhamel, Stephanie
    Zaoui, Kossay
    [J]. BIO-PROTOCOL, 2020, 10 (20):
  • [10] Evaluation of left ventricular systolic dyssynchrony by two-dimensional speckle tracking imaging and real-time three-dimensional echocardiography
    吕函璐
    刘英梅
    韦育林
    邱琼
    [J]. South China Journal of Cardiology, 2015, 16 (02) : 80 - 87