Application of pharmacokinetics to electron-beam tomography of the abdomen

被引:1
|
作者
Krause, W
Gröll, R
Kern, R
Baumgartner, C
Rienmüller, R
机构
[1] Schering AG, Res Labs, D-1342 Berlin, Germany
[2] Graz Univ, Radiol Klin, Klin Abt Allgermeine Radiol Diagnost, A-8010 Graz, Austria
关键词
aorta; electron-beam tomography; liver; pancreas; portal vein; spleen; time-attenuation curve; vena cava;
D O I
10.1016/S1076-6332(99)80168-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The purpose of this study was to evalute the pharmacokinetics of abdominal time-attenuation curves obtained at electron-beam tomography. Materials and Methods. Computed tomographic enhancement data of the aorta, portal vein, vena cava, liver, spleen, and pancreas were obtained in 25 patients after injection of 50 mL of contrast medium. These data were used to calculate pharmacokinetic parameters such as half-lives, mean residence times, and areas under the curve with a computer program. Results, Maximal enhancement was observed in the aorta 24 seconds +/- 5 (mean +/- standard deviation) after starting the injection of contrast medium (178 HU +/- 56), in the portal vein after 42 seconds +/- 14 (60 HU +/- 17), in the vena cava after 35 seconds +/- 7 (66 HU +/- 23), in the liver after 58 seconds +/- 15 (24 HU +/- 6), in the spleen after 35 seconds +/- 12 (42 HU +/- 16), and in the pancreas after 39 seconds +/- 15 (42 HU +/- 10). Half-lives of the last phase observed were 108 seconds +/- 123 in the aorta, 33 seconds +/- 30 in the portal vein, 49 seconds +/- 40 in the vena cava, 50 seconds +/- 54 in the liver, 62 seconds +/- 33 in the spleen, and 22 seconds +/- 27 in the pancreas. The computer program allowed for excellent fitting curves to the measured attenuation values and for subsequent calculation of pharmacokinetic parameters. New dosage regimens also could be simulated successfully. Conclusion. The pharmacokinetic parameters evaluated might be useful in the optimization of dosing and scanning parameters of the abdomen for ultrafast and helical CT.
引用
收藏
页码:487 / 495
页数:9
相关论文
共 50 条
  • [1] Electron-beam computed tomography
    Cheng, TO
    [J]. ANNALS OF EMERGENCY MEDICINE, 1999, 34 (02) : 295 - 296
  • [2] Electron-beam computed tomography - Reply
    Laudon, DA
    Vukov, LF
    [J]. ANNALS OF EMERGENCY MEDICINE, 1999, 34 (02) : 296 - 296
  • [3] Usefulness of electron-beam computed tomography
    Salazar, HP
    Raggi, P
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (4A): : 17B - 22B
  • [4] Functional imaging with electron-beam computed tomography
    Becker, A
    Becker, C
    Knez, A
    Haberl, R
    Brüning, R
    Reiser, M
    Steinbeck, G
    [J]. RADIOLOGE, 1998, 38 (12): : 1021 - 1028
  • [5] Usefulness of electron-beam computed tomography - Discussion
    Crouse, JR
    Raggi, P
    Black, D
    Hecht, H
    Grines, C
    Budoff, M
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (4A): : 22B - 23B
  • [6] WIDENING FIELD OF APPLICATION OF ELECTRON-BEAM
    不详
    [J]. MACHINERY AND PRODUCTION ENGINEERING, 1972, 120 (3088): : 73 - &
  • [7] APPLICATION OF ELECTRON-BEAM IRRADIATION IN MICROLITHOGRAPHY
    PETHRICK, RA
    [J]. RADIATION PHYSICS AND CHEMISTRY, 1991, 37 (02): : 331 - 346
  • [8] AN APPLICATION OF ROTATIONAL ELECTRON-BEAM THERAPY
    SHACKLETON, D
    BARRY, LM
    PHILLIPS, RA
    MEYER, CB
    MEDCALF, AG
    KORRUBEL, JB
    ROMBOUTS, T
    BURET, EAJ
    [J]. SOUTH AFRICAN JOURNAL OF SCIENCE, 1984, 80 (09) : 439 - 439
  • [9] CT imaging of the abdomen: Electron-beam versus spiral and sequential scanning
    Schoepf, UO
    Bruening, RD
    Becker, CR
    Rogalla, P
    Georgi, M
    Reiser, MF
    [J]. RADIOLOGY, 1998, 209P : 409 - 409
  • [10] APPLICATION OF BEAM OSCILLATED ELECTRON-BEAM WELDING FOR MOLYBDENUM
    HIRAOKA, Y
    IRIE, H
    OKADA, M
    WATANABE, R
    [J]. TRANSACTIONS OF NATIONAL RESEARCH INSTITUTE FOR METALS, 1984, 26 (02): : 115 - 121