Chloramination: Its effect on distribution system water quality

被引:1
|
作者
Norton, CD [1 ]
LeChevallier, MW [1 ]
机构
[1] AWWSC,VOORHEES,NJ 08043
来源
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Postdisinfection using chloramines can limit coliform regrowth in pipeline biofilms and formation of disinfection by-products (DBPs) in distribution systems. Two utilities that have had occurrences of total coliform converted from free chlorine to chloramines. Water in both distribution systems was monitored for biological and chemical quality for a year after the conversion, Coliform occurrences were eliminated in one system and reduced fourfold in the other. However, excessive concentrations of assimilable organic carbon (up to 375 mu g/L) were characteristic of the latter system, as was pitting corrosion. Both factors may play a critical role in limiting coliform occurrence. Postdisinfection using chloramines rather than free chlorine has advantages including decreased coliform concentrations, decreased heterotrophic plate count and DBPs, and improved maintenance of a disinfectant residual. However chloramination alone may not be sufficient to control coliform concentrations in all distribution systems.
引用
下载
收藏
页码:66 / 77
页数:12
相关论文
共 50 条
  • [2] Mixing in distribution system storage tanks: Its effect on water quality
    Clark, RM
    Abdesaken, F
    Boulos, PF
    Mau, RE
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1996, 122 (09): : 814 - 821
  • [3] Water quality in Montreal: Effect of the distribution system
    Desjardins, R.
    Jutras, L.
    Prevost, M.
    Revue des Sciences de l'Eau, 1997, 10 (02): : 167 - 184
  • [4] Chloramination to preserve microbiological quality: experience at Rand water
    Geldenhuys, J.
    Water Supply, 13 (02):
  • [5] Distribution System Water Quality
    Gagnon, Graham
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2012, 104 (01): : 66 - 68
  • [6] Distribution system water quality
    National Sciences and Engineering Research Council, Canada
    不详
    Gagnon, G., 2012, American Water Works Association (104):
  • [7] Transformation of bisphenol A during chloramination in a pilot-scale water distribution system: Effect of pH, flow velocity and type of pipes
    He, Guilin
    Li, Cong
    Zhang, Tuqiao
    Zhao, Jingguo
    Sharma, Virender K.
    Cizmas, Leslie
    CHEMICAL ENGINEERING JOURNAL, 2017, 312 : 275 - 287
  • [8] Drinking water chlorination and chloramination in water distribution system: Release of lead, formation of disinfection byproducts (DBPs) and toxicity of tap water
    Liu, Jiaqi
    Li, Wanxin
    Li, Yu
    Zhang, Xiangru
    Lujan, Henry
    Sayes, Christie
    Sharma, Virender
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [9] Water Quality Management in a Water Distribution System
    Kowalski, Dariusz
    OCHRONA SRODOWISKA, 2009, 31 (03): : 37 - 40
  • [10] MODELING THE DISTRIBUTION OF CHLORAMINES DURING DRINKING-WATER CHLORAMINATION
    YOON, JY
    JENSEN, JN
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 206 : 22 - ENVR