Optimization of condition of ultrasonic beam for measurement of small change in thickness of arterial wall

被引:5
|
作者
Watanabe, M [1 ]
Hasegawa, H [1 ]
Kanai, H [1 ]
机构
[1] Tohoku Univ, Grad Sch Engn, Dept Elect Engn, Aoba Ku, Sendai, Miyagi 9808579, Japan
关键词
atherosclerosis; change in thickness of arterial wall; computer simulation; acoustic lens; focus;
D O I
10.1143/JJAP.41.3613
中图分类号
O59 [应用物理学];
学科分类号
摘要
We previously developed a method for measuring small changes in thickness of the arterial wall during one cardiac cycle. Knowledge of this change in thickness is useful for in vivo assessment of the-regional elasticity of the arterial wall. In this study, from computer simulations, it is found that measurement error depends on the distance of the ultrasonic beam from the center of the artery and it can be reduced by optimally setting the focal position. In basic experiments using a silicone rubber tube and in in vivo experiments with a human carotid artery, it is found that by optimizing the focal position, measurement of the change in thickness becomes more robust against mispositioning of the ultrasonic beam. From these results, it is demonstrated that optimum focal positioning provides more robustness in measurement, even if there is arterial wall motion causing the position of the ultrasonic beam to deviate from the center of the artery.
引用
收藏
页码:3613 / 3618
页数:6
相关论文
共 50 条
  • [1] Optimization of focal position of ultrasonic beam in measurement of small change in arterial wall thickness
    Watanabe, M.
    Kanai, H.
    [J]. Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2001, 40 (5 B): : 3918 - 3921
  • [2] Optimization of focal position of ultrasonic beam in measurement of small change in arterial wall thickness
    Watanabe, M
    Kanai, H
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2001, 40 (5B): : 3918 - 3921
  • [3] Reduction of influence of decrease in SNR of ultrasonic pulse during cardiac cycle in measurement of small change in thickness of arterial wall
    Hasegawa, H
    Kanai, H
    Hoshimiya, N
    Koiwa, Y
    [J]. 1999 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 1999, : 1337 - 1340
  • [4] Modified phased tracking method for measurement of change in thickness of arterial wall
    Hasegawa, Hideyuki
    Kanai, Hiroshi
    Koiwa, Yoshiro
    [J]. Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2002, 41 (5 B): : 3563 - 3571
  • [5] Modified phased tracking method for measurement of change in thickness of arterial wall
    Hasegawa, H
    Kanai, H
    Koiwa, Y
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2002, 41 (5B): : 3563 - 3571
  • [6] Ultrasonic measurement of thickness of carotid arterial wall using its natural longitudinal displacement
    Nagai, Yoshifumi
    Mori, Shohei
    Arakawa, Mototaka
    Kanai, Hiroshi
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 2023, 62 (SJ)
  • [7] Measurement uncertainty evaluation of ultrasonic wall thickness measurement
    Mihaljevic, Morana
    Markucic, Damir
    Runje, Biserka
    Keran, Zdenka
    [J]. MEASUREMENT, 2019, 137 : 179 - 188
  • [8] An appraisal of ultrasonic wall thickness measurement practices
    Lilley, JR
    [J]. CAPE '99: AGEING OF MATERIALS AND METHODS FOR THE ASSESSMENT OF LIFETIMES OF ENGINEERING PLANT, 1999, : 165 - 179
  • [9] LIMITS OF WALL-THICKNESS MEASUREMENT WITH ULTRASONIC THICKNESS GAUGES
    FRIELINGHAUS, R
    CARODISKEY, T
    [J]. MATERIALS EVALUATION, 1985, 43 (10) : 1310 - 1310
  • [10] Sources of arterial wall thickness measurement variability
    Crouse, JR
    [J]. INTIMA-MEDIA THICKNESS AN ATHEROSCLEROSIS: PREDICTING THE RISK?, 1997, : 59 - 67