Comparison of the characteristics of the leachate and the eluates obtained by different methods

被引:5
|
作者
Kocasoy, Guenay [1 ]
Murat, Zeynep Melda [1 ]
机构
[1] Bogazici Univ, Inst Environm Sci, TR-34342 Istanbul, Turkey
关键词
Eluate; leachate; SLT; IUCS 48 hours shake test; Minnesota test; DIN38414-S4; test; LANDFILL; WASTES; RECIRCULATION; LEACHABILITY;
D O I
10.1080/10934520902784666
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the research conducted, the interrelation between the leachate and eluates obtained by different methods was determined. The purpose of this research is to determine the optimum method yielding the eluates resembling the leachate generated from the same solid waste. Two reactors filled with solid waste, simulating to a certain extent the sanitary landfill conditions, were used for the generation of leachate. Eluates from the same solid waste that was filled in the reactors were produced by different methods - Standard Leaching Test (SLT), International Unit Conversion System (IUCS) 48 Hours Shaking Test, Minnesota Test and Deutches Institut fur Normung (DIN) 38414-S4 Test. Then both the leachate generated in the reactors and the eluates obtained were analyzed for pH, biological oxygen demand (BOD), chemical oxygen demand (COD), 11 metals and inorganic elements and the results obtained were compared. The BOD and COD values of the SLT third day eluation have higher values than the eluates obtained by other methods. pH values of all the eluates are close to each other. The BOD, COD, Cu, Mn, Zn values of eluates obtained by SLT third eluation have the highest conformity to the leachate generated in reactors. The ratios of the average BOD, COD, Cu, Mg, Mn, Ni and Zn values of the leachate generated at the reactors to eluate are 0.9, 1.2, 0.65, 20, 1, 2.5 and 0.5, respectively. The average value of Ca concentration of the same eluate is 35 times lower than the average values of the leachate generated of the reactors. The eluate obtained by DIN 38414-S4 test has closest Fe and Pb values to the values of the leachate, but still Fe value is four times less than the average Fe values of the reactors. The ratio of Pb values of leachate to eluate is 0.6. The results showed that the SLT third day eluation yields the eluate having the closest values to the characteristics of the leachate generated at the reactors.
引用
收藏
页码:605 / 614
页数:10
相关论文
共 50 条
  • [1] Comparison of dynamic characteristics of an office building obtained from different experimental methods
    Ventura, CE
    Latendresse, V
    [J]. IMAC - PROCEEDINGS OF THE 17TH INTERNATIONAL MODAL ANALYSIS CONFERENCE, VOLS I AND II, 1999, 3727 : 1069 - 1075
  • [2] Comparison of Covariance Matrices Obtained by Different Methods
    Neudecker, D.
    St Gundacker
    Srdinko, Th
    Wildpaner, V.
    Leeb, H.
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 59 (02) : 1272 - 1275
  • [3] A COMPARISON OF HERITABILITY ESTIMATES OBTAINED BY DIFFERENT METHODS
    SRINIVAS.G
    SHRODE, RR
    LIDVALL, ER
    [J]. JOURNAL OF ANIMAL SCIENCE, 1969, 29 (01) : 112 - &
  • [4] COMPARISON OF HEMOLYSIN PREPARATIONS OBTAINED BY DIFFERENT METHODS
    NAGY, G
    FODOR, D
    SZATHMARY, J
    [J]. ACTA VETERINARIA ACADEMIAE SCIENTIARUM HUNGARICAE, 1973, 23 (04): : 273 - 278
  • [5] A COMPARISON OF ELASTICITIES OF DEMAND OBTAINED BY DIFFERENT METHODS
    Schultz, Henry
    [J]. ECONOMETRICA, 1933, 1 (03) : 274 - 308
  • [6] Comparison of Different Oxidation Methods for Recalcitrance Removal of Landfill Leachate
    Van Aken, Pieter
    Lambert, Nico
    Degreve, Jan
    Liers, Sven
    Luyten, Jan
    [J]. OZONE-SCIENCE & ENGINEERING, 2011, 33 (04) : 294 - 300
  • [7] Production and comparison of structural, thermal and physical characteristics of chitin nanoparticles obtained by different methods
    Farokhi, Neda Moshtaghi
    Milani, Jafar Mohammadzadeh
    Amiri, Zeinab Raftani
    [J]. SCIENTIFIC REPORTS, 2024, 14 (01):
  • [8] COMPARISON OF ANAEROBIC SUSCEPTIBILITY RESULTS OBTAINED BY DIFFERENT METHODS
    ROSENBLATT, JE
    MURRAY, PR
    SONNENWIRTH, AC
    JOYCE, JL
    [J]. ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1979, 15 (03) : 351 - 355
  • [9] Comparison of Stress Concentration Factors Obtained by Different Methods
    Sivak, Peter
    Delyova, Ingrid
    Bocko, Jozef
    [J]. APPLIED SCIENCES-BASEL, 2023, 13 (24):
  • [10] Comparison of sound absorption coefficients obtained by different methods
    Willig, FJ
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1939, 10 (04): : 293 - 299