Twenty-Four-Hour Cardiovascular Effects of Electronic Cigarettes Compared With Cigarette Smoking in Dual Users

被引:16
|
作者
Benowitz, Neal L. [1 ,2 ,3 ]
St Helen, Gideon [1 ,2 ,3 ]
Nardone, Natalie [1 ]
Addo, Newton [1 ]
Zhang, Junfeng [4 ,5 ,6 ]
Harvanko, Arit M. [1 ,2 ,3 ]
Calfee, Carolyn S. [7 ,8 ]
Jacob, Peyton, III [1 ,2 ,3 ,9 ]
机构
[1] Univ Calif San Francisco, Clin Pharmacol Res Program, Div Cardiol, Dept Med, Box 1220, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Ctr Tobacco Control Res & Educ, San Francisco, CA 94143 USA
[3] Univ Calif San Francisco, Tobacco Ctr Regulatory Sci, San Francisco, CA 94143 USA
[4] Duke Univ, Global Hlth Inst, Durham, NC USA
[5] Duke Univ, Nicholas Sch Environm, Durham, NC 27708 USA
[6] Duke Univ, Duke Canc Inst, Durham, NC USA
[7] Univ Calif San Francisco, Dept Med, Div Pulm Crit Care Allergy & Sleep Med, San Francisco, CA 94143 USA
[8] Univ Calif San Francisco, Dept Anaesthesia, San Francisco, CA USA
[9] Univ Calif San Francisco, Dept Psychiat, San Francisco, CA USA
来源
关键词
biomarkers; electronic cigarettes; nicotine; tobacco; SMOKELESS TOBACCO; NICOTINE; EXPOSURE; TOLERANCE; MORTALITY; COTININE; SMOKERS; RISK;
D O I
10.1161/JAHA.120.017317
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Cardiovascular safety is an important consideration regarding the benefits versus risks of electronic cigarette use (EC) for public health. The single-use cardiovascular effects of EC have been well studied but may not reflect effects of ad libitum use throughout the day. We aimed to compare the circadian hemodynamic effects as well as 24-hour biomarkers of oxidative stress, and platelet aggregation and inflammation, with ad libitum cigarette smoking (CS) versus EC versus no tobacco product use. Methods and Results: Thirty-six healthy dual CS and EC users participated in a crossover study in a confined research setting. Circadian heart rate, blood pressure and plasma nicotine levels, 24-hour urinary catecholamines, 8-isoprostane and 11-dehydro-thromboxane B2, and plasma interleukin-6 and interleukin-8 were compared in CS, EC, and no nicotine conditions. Over 24 hours, and during daytime, heart rate and blood pressure were higher in CS and EC compared with no tobacco product conditions (P<0.01). Heart rate on average was higher with CS versus EC. Urinary catecholamines, 8-isoprostane, and 11-dehydro-thromboxane B2 were not significantly different, but plasma IL-6 and IL-8 were higher with both CS and EC compared with no tobacco product (P<0.01). Conclusions: CS and EC had similar 24-hour patterns of hemodynamic effects compared with no tobacco product, with a higher average heart rate with CS versus EC, and similar effects on biomarkers of inflammation. EC may pose some cardiovascular risk, particularly to smokers with underlying cardiovascular disease, but may also provide a harm reduction opportunity for smokers willing to switch entirely to EC. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique Identifier: NCT02470754.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Twenty-four-hour subjective and pharmacological effects of ad-libitum electronic and combustible cigarette use among dual users
    Harvanko, Arit M.
    St Helen, Gideon
    Nardone, Natalie
    Addo, Newton
    Benowitz, Neal L.
    [J]. ADDICTION, 2020, 115 (06) : 1149 - 1159
  • [2] Smoking cessation support for dual users of cigarettes and electronic cigarettes
    Brown, Jamie
    Shahab, Lion
    [J]. LANCET PUBLIC HEALTH, 2021, 6 (07): : E441 - E442
  • [3] Twenty-Four-Hour Patterns in Occurrence and Pathophysiology of Acute Cardiovascular Events and Ischemic Heart Disease
    Manfredini, Roberto
    Boari, Benedetta
    Salmi, Raffaella
    Fabbian, Fabio
    Pala, Marco
    Tiseo, Ruana
    Portaluppi, Francesco
    [J]. CHRONOBIOLOGY INTERNATIONAL, 2013, 30 (1-2) : 6 - 16
  • [4] Twenty-four-hour rhythms of plasma catecholamines and their relation to cardiovascular parameters in healthy young men
    Schöfl, C
    Becker, C
    Prank, K
    Von Zur Mühlen, A
    Brabant, G
    [J]. EUROPEAN JOURNAL OF ENDOCRINOLOGY, 1997, 137 (06) : 675 - 683
  • [5] Effects of smoking and smoking cessation on twenty-four hour blood pressure
    Marinheiro, A. R.
    Amador, P.
    Sa, C.
    Duarte, T.
    Fonseca, M.
    Rodrigues, R.
    Silvestre, I.
    Bernardino, L.
    Caria, R.
    [J]. EUROPEAN HEART JOURNAL, 2016, 37 : 223 - 223
  • [6] Acute Effects of Prolonged Physical Exercise: Evaluation After a Twenty-Four-Hour Ultramarathon
    Passaglia, Daniela Guinther
    Marin Emed, Luiz Gustavo
    Barberato, Silvio Henrique
    Guerios, Surya Toledo
    Moser, Andre Isolani
    Fernandes Silva, Miguel Morita
    Ishie, Elissa
    Guarita-Souza, Luiz Cesar
    Frack Costantini, Costantino Roberto
    Faria-Neto, Jose Rocha
    [J]. ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2013, 100 (01) : 21 - 27
  • [7] Effects of electronic cigarette use on arterial elasticity compared to cigarette smoking
    Farsalinos, K.
    Tsiapras, D.
    Kyrzopoulos, S.
    Spyrou, A.
    Stefopoulos, C.
    Tsimopoulou, K.
    Voudris, V.
    [J]. EUROPEAN HEART JOURNAL, 2014, 35 : 877 - 877
  • [8] E-cigarette characteristics and cigarette smoking cessation behaviors among US Adult dual users of cigarettes and e-cigarettes
    Zavala-Arciniega, Luis
    Hirschtick, Jana L.
    Meza, Rafael
    Fleischer, Nancy L.
    [J]. PREVENTIVE MEDICINE REPORTS, 2022, 26
  • [9] Daily Cigarette Consumption and Urine Cotinine Level between Dual Users of Electronic and Conventional Cigarettes, and Cigarette-Only Users
    Kim, Jinyoung
    Lee, Sungkyu
    [J]. JOURNAL OF PSYCHOACTIVE DRUGS, 2020, 52 (01) : 20 - 26
  • [10] Negative Affect and Cigarette Cessation in Dual Users of Cigarettes and Electronic Nicotine Delivery Systems
    Brooks, Julia M.
    Mermelstein, Robin J.
    [J]. SUBSTANCE USE & MISUSE, 2022, 57 (08) : 1294 - 1302