Use of classical least squares/partial least squares (CLS/PLS) hybrid algorithm for calibration and calibration maintenance of surface acoustic wave (SAW) devices

被引:7
|
作者
Rivera, D
Alam, MK [1 ]
Yelton, WG
Staton, AW
Simonson, RJ
机构
[1] Chem & Biol Sensing Imaging & Anal, Albuquerque, NM 87185 USA
[2] Photon Microsyst Technol, Albuquerque, NM 87185 USA
[3] Micro Analyt Syst, Albuquerque, NM 87185 USA
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2004年 / 99卷 / 2-3期
关键词
CLS/PLS; SAW devices; calibration; calibration maintenance;
D O I
10.1016/j.snb.2003.12.076
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Many data analysis algorithms that are currently employed in SAW sensors lack the ability to easily maintain calibration models in the presence of unmodeled interferents or sensor drift. The classical least squares/partial least squares (CLS/PLS) hybrid algorithm is tested in this study for its ability to update calibration models for unmodeled interferents and sensor drift with information from only a single recalibration standard. Use of the CLS/PLS hybrid algorithm for calibration and calibration maintenance of surface acoustic wave (SAW) devices was investigated for synthetic mixtures of iso-octane-methanol-water and with synthetic mixtures of nerve agent analogs, di-iso-propyl methyl phosphonate (DIMP)-kerosene-water along with a true ternary mixture of dimethyl methyl phosphonate (DMMP)-kerosene-water. Calibration statistics using the hybrid algorithm were found to be as good as those obtained from a standard partial least squares (PLS) analysis. In prediction, the hybrid algorithm models were found to perform equivalently to PLS models in the absence of unmodeled interferents or sensor drift, with an accuracy of 5-10% of the reference values and a high degree of precision. In the case of prediction in the presence of unmodeled interferents and/or sensor drift, PLS models and prediction augmented CLS/PLS (PACLS/PLS) hybrid models were compared using a single standard sample to update each model for prediction. For the cases studied, PACLS/PLS hybrid models were comparable to or outperformed updated PLS models that used subset recalibration or piece-wise direct standardization. (C) 2004 Published by Elsevier B.V.
引用
收藏
页码:480 / 490
页数:11
相关论文
共 50 条
  • [1] New classical least-squares/partial least-squares hybrid algorithm for spectral analyses
    Haaland, DM
    Melgaard, DK
    [J]. APPLIED SPECTROSCOPY, 2001, 55 (01) : 1 - 8
  • [2] Concentration residual augmented classical least squares (CRACLS): A multivariate calibration method with advantages over partial least squares
    Melgaard, DK
    Haaland, DM
    Wehlburg, CM
    [J]. APPLIED SPECTROSCOPY, 2002, 56 (05) : 615 - 624
  • [3] Abilities of partial least squares (PLS) multivariate calibration in the analysis of a quaternary mixture of sulfonamides
    EspinosaMansilla, A
    Salinas, F
    Paya, ID
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 354 (02): : 245 - 249
  • [4] A NOTE ON THE USE OF THE PARTIAL LEAST-SQUARES METHOD FOR MULTIVARIATE CALIBRATION
    LORBER, A
    KOWALSKI, BR
    [J]. APPLIED SPECTROSCOPY, 1988, 42 (08) : 1572 - 1574
  • [5] Classical Least Squares (CLS), Part 3: Expanding the Analysis to Include Concentration Information on Principal Component Regression (PCR) and Partial Least Squares (PLS) Algorithms
    Mark, Howard
    Workman, Jerome, Jr.
    [J]. SPECTROSCOPY, 2020, 35 (10) : 17 - 23
  • [6] Classical least squares (cls), part 3: Expanding the analysis to include concentration information on principal component regression (pcr) and partial least squares (pls) algorithms
    Mark, Howard
    Workman, Jerome
    [J]. Spectroscopy (Santa Monica), 2020, 35 (10): : 17 - 23
  • [7] Partial least squares-slice transform hybrid model for nonlinear calibration
    Shan, Peng
    Peng, Silong
    Bi, Yiming
    Tang, Liang
    Yang, Chixiao
    Xie, Qiong
    Li, Changwen
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2014, 138 : 72 - 83
  • [8] Subspace partial least squares model for multivariate spectroscopic calibration
    Ge, Zhiqiang
    Song, Zhihuan
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2013, 125 : 51 - 57
  • [9] Construction of global and robust near-infrared calibration models based on hybrid calibration sets using Partial Least Squares (PLS) regression
    Ni, Lijun
    Xiao, Lixia
    Yao, Heming
    Ge, Jiong
    Zhang, Liguo
    Luan, Shaorong
    [J]. ANALYTICAL LETTERS, 2019, 52 (07) : 1177 - 1194
  • [10] Dynamic Process Calibration Based on Sparse Partial Least Squares
    Wen, Qiaojun
    Ge, Zhiqiang
    Song, Zhihuan
    Wang, Peiliang
    [J]. 2014 11TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA), 2014, : 1366 - 1371