In vivo studies of an implantable energy convertor for skeletal muscle powered cardiac assist

被引:0
|
作者
Reichenbach, SH
Farrar, DJ
Diao, E
Hill, JD
机构
[1] UNIV CALIF SAN FRANCISCO,SAN FRANCISCO,CA 94143
[2] CALIF PACIFIC MED CTR,SAN FRANCISCO,CA
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A device that harnesses the mechanical energy of skeletal muscle contracting in a linear configuration has been implanted in goats. This energy convertor transforms muscle work to hydraulic energy that could drive a variety of cardiac assist devices. The device is mounted with a rib clamp and plate affixed to the sternum by cortical bone screws. A transcutaneous hydraulic line carries a silicon based working fluid to an external system that controls the muscle load. In 60 to 70 kg goats, the latissimus dorsi insertion was reattached to the energy convertor. A Telectronics myostimulator with intramuscular electrodes stimulated the latissimus dorsi. In acute implants, hydraulic pressures in excess of 150 psi were obtained. Chronic implantation of the device allowed system evaluation in the conscious unanesthetized animal. Two weeks after implant, hydraulic pressures in excess of 200 psi were obtained and energy transferred to the external loading system exceeded 1 J per contraction. Six weeks after implant, the device continued to cycle freely. These initial results are very promising and suggest an implantable energy convertor is feasible. Development of an energy convertor is an important step toward tether-free skeletal muscle powered cardiac assist devices.
引用
收藏
页码:M668 / M672
页数:5
相关论文
共 50 条
  • [1] Chronic implantation of a skeletal muscle energy convertor for cardiac assist devices - A preliminary report
    Reichenbach, SH
    Gustafson, KJ
    Khazalpour, KM
    Farrar, DJ
    Hill, JD
    [J]. ASAIO JOURNAL, 1998, 44 (05) : M745 - M749
  • [2] Functional properties of conditioned skeletal muscle: implications for muscle-powered cardiac assist
    Trumble, DR
    LaFramboise, WA
    Duan, CP
    Magovern, JA
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-CELL PHYSIOLOGY, 1997, 273 (02): : C588 - C597
  • [3] A ventricular assist device powered by conditioned skeletal muscle
    Whalen, RL
    Richards, CL
    Lim, GW
    Sherman, CW
    Norman, JC
    Bearnson, GB
    Burns, GL
    Olsen, DB
    [J]. ANNALS OF THORACIC SURGERY, 1999, 68 (02): : 780 - 784
  • [4] THE MUSCLE-POWERED DUAL-CHAMBER COUNTERPULSATOR - RHEOLOGICALLY SUPERIOR IMPLANTABLE CARDIAC ASSIST DEVICE
    KOCHAMBA, G
    DESROSIERS, C
    DEWAR, M
    CHIU, RCJ
    [J]. ANNALS OF THORACIC SURGERY, 1988, 45 (06): : 620 - 625
  • [5] IMPLANTABLE EXTRA-AORTIC BALLOON ASSIST POWERED BY TRANSFORMED FATIGUE-RESISTANT SKELETAL-MUSCLE
    CHIU, RCJ
    WALSH, GL
    DEWAR, ML
    DESIMON, JH
    KHALAFALLA, AS
    IANUZZO, D
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1987, 94 (05): : 694 - 701
  • [6] Power generation from four skeletal muscle configurations - Design implications for a muscle powered cardiac assist device
    Badhwar, V
    Badhwar, RK
    Oh, JH
    Chiu, RCJ
    [J]. ASAIO JOURNAL, 1997, 43 (05) : M651 - M657
  • [7] Evaluation of a skeletal muscle energy convertor in a chronic animal model
    Reichenbach, SH
    Gustafson, KJ
    Egrie, GD
    Weidman, JR
    Farrar, DJ
    Hill, JD
    [J]. ASAIO JOURNAL, 2000, 46 (04) : 482 - 485
  • [8] MUSCLE POWERED EXTRA AORTIC BALLOON FOR CARDIAC ASSIST
    KHALAFALLA, AS
    NEILSON, IR
    CHIU, RCJ
    [J]. ARTIFICIAL ORGANS, 1987, 11 (04) : 327 - 327
  • [9] THE MUSCLE-POWERED DUAL-CHAMBER COUNTERPULSATOR - RHEOLOGICALLY SUPERIOR IMPLANTABLE CARDIAC ASSIST DEVICE - UPDATED
    CHIU, RCJ
    [J]. ANNALS OF THORACIC SURGERY, 1995, 59 (03): : 782 - 783
  • [10] ERGOMETRIC STUDIES OF UNTRAINED SKELETAL-MUSCLE DEMONSTRATE FEASIBILITY OF MUSCLE-POWERED CARDIAC ASSISTANCE
    TRUMBLE, DR