Simultaneous determination of peroxydisulfate and conventional inorganic anions by ion chromatography with the column-switching technique

被引:23
|
作者
Huang, Zhongping [1 ]
Ni, Chengzhu [1 ]
Wang, Fengli [1 ]
Zhu, Zuoyi [1 ]
Subhani, Qamar [1 ]
Wang, Muhua [2 ]
Zhu, Yan [1 ]
机构
[1] Zhejiang Univ, Dept Chem, Hangzhou 310028, Zhejiang, Peoples R China
[2] Lishui Univ, Dept Chem, Lishui, Peoples R China
关键词
Column switching; Conventional inorganic anions; Ion chromatography; Peroxydisulfate; SPECTROPHOTOMETRIC DETERMINATION; IODOMETRIC METHOD; AQUEOUS-SOLUTIONS; FLASH-PHOTOLYSIS; PERSULFATE; KINETICS; MICRODETERMINATION; EXCHANGE; DECOMPOSITION; SEPARATION;
D O I
10.1002/jssc.201300583
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The application of ion chromatography with the column-switching technique for the simultaneous analysis of peroxydisulfate and conventional inorganic anions in a single run is described. With this method, conventional inorganic anions were separated by consecutive elution through both the guard column and separation column, but peroxydisulfate that only passed through the guard column had a good peak shape and short retention time. A series of standard solutions consisting of target anions of various concentrations from 0.01 to 75 mg/L were analyzed, with a correlation coefficient (r) >= 0.9990. The limits of detection were in the range of 0.49-9.84 mu g/L based on the S/N of 3 and a 25 mu L injection volume. RSDs for retention time, peak area, and peak height were all <1.77%. A spiking study was performed with satisfactory recoveries between 97.6 and 103.4% for all anions. The quantitative determination of peroxydisulfate and conventional inorganic anions in surface waters was accomplished within 18 min by this column-switching technique.
引用
收藏
页码:198 / 203
页数:6
相关论文
共 50 条
  • [1] DETERMINATION OF INORGANIC AND ORGANIC-ANIONS IN ONE RUN BY ION CHROMATOGRAPHY WITH COLUMN-SWITCHING
    UMILE, C
    HUBER, JFK
    JOURNAL OF CHROMATOGRAPHY, 1993, 640 (1-2): : 27 - 31
  • [2] Determination of trace inorganic anions in anionic surfactants by single-pump column-switching ion chromatography
    Zhang, Jia Jie
    Zhu, Hai Bao
    Zhu, Yan
    CHINESE CHEMICAL LETTERS, 2012, 23 (07) : 835 - 838
  • [4] Determination of Trace Inorganic Anions in Weak Acids by Single-Pump Column-Switching Ion Chromatography
    Zhu, Haibao
    Chen, Huadong
    Zhong, Yingying
    Ren, Dandan
    Qian, Yaling
    Tang, Hongfang
    Zhu, Yan
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2010, 48 (07) : 553 - 558
  • [5] Determination of inorganic anions in weak acids by using ion exclusion chromatography - Capillary ion chromatography switching column technique
    Ye, Mingli
    Nesterenko, Pavel N.
    Yan, Zhu
    Xie, Peijing
    Chen, Meilan
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1588 : 169 - 173
  • [6] Simultaneous multi-component determination of food by column-switching ion chromatography
    Zhu, Y
    Mu, WJ
    ANALYTICAL LETTERS, 1996, 29 (10) : 1817 - 1828
  • [7] Determination of Impurity Anions in High Pure Fluoride Reagents by Ion Chromatography with Column-Switching
    Hu Zhong-Yang
    Ye Ming-Li
    Wu Shu-Chao
    Pan Guang-Wen
    Zhang Ting-Ting
    Liu Lu-Ye
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (11) : 1703 - 1708
  • [8] USE OF COLUMN-SWITCHING TECHNIQUE IN PHOTOMETRIC ION CHROMATOGRAPHY
    YOSHIDA, I
    HAYAKAWA, K
    MIYAZAKI, M
    NIPPON KAGAKU KAISHI, 1986, (07) : 1046 - 1049
  • [9] Determination of fluoride in soil water extract by ion chromatography with column-switching technique
    Jiang Xinhua
    Ni Chengzhu
    Zhu Binhe
    Zhao Xunyan
    Chen Suqing
    Lu Weide
    Zhang Jiajie
    Zhang Peimin
    Li Gang
    Zhu Yan
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2016, 34 (04) : 442 - 446
  • [10] Determination of ammonium in seawater by column-switching ion chromatography
    Huang, Y
    Mou, S
    Riviello, JM
    JOURNAL OF CHROMATOGRAPHY A, 2000, 868 (02) : 209 - 216