共 50 条
Recovery of phosphate and ammonium nitrogen as struvite from aqueous solutions using a magnesium-air cell system
被引:14
|作者:
Wu, Xiaoyun
[1
]
Xie, Rongrong
[2
]
Ding, Jianguo
[2
]
Dai, Liping
[2
]
Ke, Xiong
[2
]
Liu, Yaoxing
[2
,3
]
Chen, Riyao
[2
]
Qian, Qingrong
[2
]
Ding, Rui
[2
]
Liu, Jianxi
[2
]
Van der Bruggen, Bart
[3
,4
]
机构:
[1] Fujian Chuanzheng Commun Coll, Sch Safety & Environm, Fuzhou 350007, Fujian, Peoples R China
[2] Fujian Normal Univ, Coll Environm Sci & Engn, Fujian Key Lab Pollut Control & Resource Reuse, Fuzhou 350007, Fujian, Peoples R China
[3] Katholieke Univ Leuven, Dept Chem Engn Proc Proc Engn Sustainable Syst, Celestijnenlaan 200F, B-3001 Leuven, Belgium
[4] Tshwane Univ Technol, Fac Engn & Built Environm, Private Bag X680, ZA-0001 Pretoria, South Africa
基金:
中国国家自然科学基金;
关键词:
Phosphorous;
Ammonium nitrogen;
Struvite;
Magnesium-air cell system;
Electricity production;
PHOSPHORUS RECOVERY;
WASTE-WATER;
REMOVAL;
CRYSTALLIZATION;
PREDICTION;
CALCIUM;
PH;
D O I:
10.1016/j.scitotenv.2021.152006
中图分类号:
X [环境科学、安全科学];
学科分类号:
08 ;
0830 ;
摘要:
The addition of alkaline and magnesium sources during the recovery of NH4+ and PO4+ in the form of struvite using the traditional struvite precipitation method increases the production cost. To solve this problem, a magnesium-air cell (MAC) system was used herein to recover NH4+ and PO4+ as struvite from wastewater using a magnesium strip (Mg2+) and the oxygen adsorbed on the surface of a titanium plate (OH-) as the anode and cathode, respectively. Experimental parameters (i.e. initial solution pH, temperature, NH4+/PO4- molar ratio, NH4+ and PO4- initial concentrations and stirring intensity) were found to affect the removal rate of NH4+ and PO4-. The presence of Ca2+ decreased the struvite purity. At Ca2+/PO4- ratios of 0:1 and 0.5:1, the purity of the obtained struvite after 6 h was 93.8% and 58.9%, respectively. Struvite with a purity of 95.7%, electricity with an average output power of 2.53 mW, and an energy density of 1.05 W/m(2) were obtained when the proposed system was used to recover NH4+ and PO4- from an actual supernatant of domestic sludge anaerobic digestion. Scanning electron microscopy- energy-dispersive X-ray spectroscopy, X-ray diffraction, Fourier transform infrared spectroscopy, Raman spectroscopy and thermogravimetric analyses showed that the obtained struvite exhibited almost the same physicochemical properties as commercial struvite. Thus, the MAC system can be regarded as an effective method for recovering NH4+ and PO4- in the form of struvite from wastewater.
引用
收藏
页数:11
相关论文