Short X-ray pulses from third-generation light sources

被引:7
|
作者
Stepanov, A. G. [1 ]
Hauri, C. P. [1 ,2 ]
机构
[1] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
[2] Ecole Polytech Fed Lausanne, CH-1015 Lausanne, Switzerland
来源
基金
瑞士国家科学基金会;
关键词
laser slicing; femtosecond X-ray pulses; picosecond X-ray pulses; X-ray pulse compression; X-ray switch; FREE-ELECTRON LASER; PHONON BRAGG SWITCH; EXTREME-ULTRAVIOLET; SYNCHROTRON-RADIATION; STORAGE-RINGS; STRUCTURAL DYNAMICS; THOMSON SCATTERING; ANGULAR-MOMENTUM; STREAK CAMERA; ARRIVAL-TIME;
D O I
10.1107/S1600577515019281
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
High-brightness X-ray radiation produced by third-generation synchrotron light sources (TGLS) has been used for numerous time-resolved investigations in many different scientific fields. The typical time duration of X-ray pulses delivered by these large-scale machines is about 50-100 ps. A growing number of time-resolved studies would benefit from X-ray pulses with two or three orders of magnitude shorter duration. Here, techniques explored in the past for shorter X-ray pulse emission at TGLS are reviewed and the perspective towards the realisation of picosecond and sub-picosecond X-ray pulses are discussed.
引用
收藏
页码:141 / 151
页数:11
相关论文
共 50 条
  • [1] A monochromator for scanning X-ray microscopy beamlines at third-generation synchrotron light sources
    vonBrenndorff, AI
    Niemann, B
    Rudolph, D
    Schmahl, G
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1996, 3 : 197 - 198
  • [2] X-ray beam/biomaterial thermal interactions in third-generation synchrotron sources
    Kuzay, TM
    Kazmierczak, M
    Hsieh, BJ
    [J]. ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY, 2001, 57 : 69 - 81
  • [3] Transverse coherence properties of X-ray beams in third-generation synchrotron radiation sources
    Geloni, Glanluca
    Saldin, Evgeni
    Schneldmiller, Evgeni
    Yurkov, Mikhail
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 588 (03): : 463 - 493
  • [4] Third-generation synchrotron radiation X-ray optics
    Freund, AK
    [J]. STRUCTURE, 1996, 4 (02) : 121 - 125
  • [5] Effect of surface roughness on the spatial coherence of X-ray beams from third-generation synchrotron radiation sources
    Wang, Y
    Xiao, TQ
    Xu, HJ
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2000, 7 : 209 - 214
  • [6] X-ray harmonics rejection on third-generation synchrotron sources using compound refractive lenses
    Polikarpov, Maxim
    Snigireva, Irina
    Snigirev, Anatoly
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2014, 21 : 484 - 487
  • [7] Insertion devices for third-generation light sources
    Inst of Physics and Chemical, Research , Saitama, Japan
    [J]. Review of Scientific Instruments, 1995, 66 (2 pt 2): : 2007 - 2010
  • [8] Visible Light Generated By Short X-ray Pulses
    Wang, Feilu
    More, Richard
    [J]. JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 2015, 84 (10)
  • [9] SOURCES OF SHORT X-RAY PULSES FOR INVESTIGATING FAST PROCESSES
    TSUKERMAN, VA
    MANAKOVA, MA
    [J]. SOVIET PHYSICS-TECHNICAL PHYSICS, 1957, 2 (02): : 353 - 363
  • [10] Anomalous X-ray scattering using third-generation synchrotron radiation
    Hosokawa, S.
    Berar, J. -F.
    [J]. SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 1743 - +