Feasibility of combined ECG-Gated and Helical acquisition mode in a pre-TAVI computed tomography angiography protocol using a fixed low-volume contrast medium injection
被引:2
|
作者:
Gallo, Giuseppe S.
论文数: 0引用数: 0
h-index: 0
机构:
Mediterranean Inst Transplantat & Adv Specialized, Radiol Unit, Via Ernesto Tricomi 5, I-90127 Palermo, ItalyMediterranean Inst Transplantat & Adv Specialized, Radiol Unit, Via Ernesto Tricomi 5, I-90127 Palermo, Italy
Gallo, Giuseppe S.
[1
]
Gerasia, Roberta
论文数: 0引用数: 0
h-index: 0
机构:
Mediterranean Inst Transplantat & Adv Specialized, Radiol Unit, Via Ernesto Tricomi 5, I-90127 Palermo, ItalyMediterranean Inst Transplantat & Adv Specialized, Radiol Unit, Via Ernesto Tricomi 5, I-90127 Palermo, Italy
Gerasia, Roberta
[1
]
Caruso, Calogero
论文数: 0引用数: 0
h-index: 0
机构:
Mediterranean Inst Transplantat & Adv Specialized, Radiol Unit, Via Ernesto Tricomi 5, I-90127 Palermo, ItalyMediterranean Inst Transplantat & Adv Specialized, Radiol Unit, Via Ernesto Tricomi 5, I-90127 Palermo, Italy
Caruso, Calogero
[1
]
Tafaro, Corrado
论文数: 0引用数: 0
h-index: 0
机构:
Mediterranean Inst Transplantat & Adv Specialized, Radiol Unit, Via Ernesto Tricomi 5, I-90127 Palermo, ItalyMediterranean Inst Transplantat & Adv Specialized, Radiol Unit, Via Ernesto Tricomi 5, I-90127 Palermo, Italy
Tafaro, Corrado
[1
]
Iannazzo, Erica
论文数: 0引用数: 0
h-index: 0
机构:
Mediterranean Inst Transplantat & Adv Specialized, Radiol Unit, Via Ernesto Tricomi 5, I-90127 Palermo, ItalyMediterranean Inst Transplantat & Adv Specialized, Radiol Unit, Via Ernesto Tricomi 5, I-90127 Palermo, Italy
Iannazzo, Erica
[1
]
Cannataci, Christine
论文数: 0引用数: 0
h-index: 0
机构:
Mater Dei Hosp, Med Imaging Dept, MSD-9032 Limsida, MaltaMediterranean Inst Transplantat & Adv Specialized, Radiol Unit, Via Ernesto Tricomi 5, I-90127 Palermo, Italy
Cannataci, Christine
[2
]
Gentile, Giovanni
论文数: 0引用数: 0
h-index: 0
机构:
Mediterranean Inst Transplantat & Adv Specialized, Radiol Unit, Via Ernesto Tricomi 5, I-90127 Palermo, ItalyMediterranean Inst Transplantat & Adv Specialized, Radiol Unit, Via Ernesto Tricomi 5, I-90127 Palermo, Italy
Gentile, Giovanni
[1
]
Mamone, Giuseppe
论文数: 0引用数: 0
h-index: 0
机构:
Mediterranean Inst Transplantat & Adv Specialized, Radiol Unit, Via Ernesto Tricomi 5, I-90127 Palermo, ItalyMediterranean Inst Transplantat & Adv Specialized, Radiol Unit, Via Ernesto Tricomi 5, I-90127 Palermo, Italy
Mamone, Giuseppe
[1
]
Gandolfo, Caterina
论文数: 0引用数: 0
h-index: 0
机构:
Mediterranean Inst Transplantat & Adv Specialized, Intervent Cardiol Unit, Via Ernesto Tricomi 5, I-90127 Palermo, ItalyMediterranean Inst Transplantat & Adv Specialized, Radiol Unit, Via Ernesto Tricomi 5, I-90127 Palermo, Italy
Gandolfo, Caterina
[3
]
Miraglia, Roberto
论文数: 0引用数: 0
h-index: 0
机构:
Mediterranean Inst Transplantat & Adv Specialized, Radiol Unit, Via Ernesto Tricomi 5, I-90127 Palermo, ItalyMediterranean Inst Transplantat & Adv Specialized, Radiol Unit, Via Ernesto Tricomi 5, I-90127 Palermo, Italy
Miraglia, Roberto
[1
]
机构:
[1] Mediterranean Inst Transplantat & Adv Specialized, Radiol Unit, Via Ernesto Tricomi 5, I-90127 Palermo, Italy
[2] Mater Dei Hosp, Med Imaging Dept, MSD-9032 Limsida, Malta
[3] Mediterranean Inst Transplantat & Adv Specialized, Intervent Cardiol Unit, Via Ernesto Tricomi 5, I-90127 Palermo, Italy
Background: To investigate the feasibility, image quality, and clinical implications of a combined ECG-gated and helical acquisition mode in a computed tomography angiography (CTA) protocol in patients scheduled for transcatheter aortic valve implantation (TAVI) using a fixed, low-volume, contrast medium injection. Methods: Between July and October 2019, 43 TAVI candidates underwent investigation with CTA using a 64-slice CT scanner. Images obtained were prospectively evaluated. 65 mL of low iodine dose contrast medium (CM), followed by 25 mL of saline, were administered using a fixed multiphasic injection protocol in all patients. Patients were divided into three groups based on BMI: Group 1 (n = 9) with BMI < 22 kg/m(2); Group 2 (n = 22) with BMI 22 29 kg/m2; Group 3 (n = 12) with BMI > 29 kg/m(2). Images were evaluated for image quality, vessel attenuation (HU), Signal-to-Noise Ratio (SNR), Contrast-to-Noise Ratio (CNR) and estimated radiation dose. Image quality of the aortic root and iliac-femoral vessels was diagnostic in all patients. Results: Vascular attenuation was > 200 HU and CNR > 3 at all vessel levels. Conclusion: Data from our study suggest that it is possible to image the aortic annulus and aorto-iliac anatomy and obtain high image quality in all patients by using a combined ECG-gated and helical acquisition mode in a computed tomography angiography (CTA) protocol with a fixed low-volume contrast medium injection (65 mL). This allows for accurate CT measurements of the aortic annulus, recruitment of patients for TAVI and facilitates pre-procedural planning in these high surgical risk patients.