Feasibility of combined ECG-Gated and Helical acquisition mode in a pre-TAVI computed tomography angiography protocol using a fixed low-volume contrast medium injection

被引:2
|
作者
Gallo, Giuseppe S. [1 ]
Gerasia, Roberta [1 ]
Caruso, Calogero [1 ]
Tafaro, Corrado [1 ]
Iannazzo, Erica [1 ]
Cannataci, Christine [2 ]
Gentile, Giovanni [1 ]
Mamone, Giuseppe [1 ]
Gandolfo, Caterina [3 ]
Miraglia, Roberto [1 ]
机构
[1] Mediterranean Inst Transplantat & Adv Specialized, Radiol Unit, Via Ernesto Tricomi 5, I-90127 Palermo, Italy
[2] Mater Dei Hosp, Med Imaging Dept, MSD-9032 Limsida, Malta
[3] Mediterranean Inst Transplantat & Adv Specialized, Intervent Cardiol Unit, Via Ernesto Tricomi 5, I-90127 Palermo, Italy
关键词
CT angiography; Contrast injection; Contrast-induced acute kidney injury; Transcatheter aortic valve implantation; AORTIC-VALVE IMPLANTATION; CT;
D O I
10.1016/j.ejrad.2020.109239
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: To investigate the feasibility, image quality, and clinical implications of a combined ECG-gated and helical acquisition mode in a computed tomography angiography (CTA) protocol in patients scheduled for transcatheter aortic valve implantation (TAVI) using a fixed, low-volume, contrast medium injection. Methods: Between July and October 2019, 43 TAVI candidates underwent investigation with CTA using a 64-slice CT scanner. Images obtained were prospectively evaluated. 65 mL of low iodine dose contrast medium (CM), followed by 25 mL of saline, were administered using a fixed multiphasic injection protocol in all patients. Patients were divided into three groups based on BMI: Group 1 (n = 9) with BMI < 22 kg/m(2); Group 2 (n = 22) with BMI 22 29 kg/m2; Group 3 (n = 12) with BMI > 29 kg/m(2). Images were evaluated for image quality, vessel attenuation (HU), Signal-to-Noise Ratio (SNR), Contrast-to-Noise Ratio (CNR) and estimated radiation dose. Image quality of the aortic root and iliac-femoral vessels was diagnostic in all patients. Results: Vascular attenuation was > 200 HU and CNR > 3 at all vessel levels. Conclusion: Data from our study suggest that it is possible to image the aortic annulus and aorto-iliac anatomy and obtain high image quality in all patients by using a combined ECG-gated and helical acquisition mode in a computed tomography angiography (CTA) protocol with a fixed low-volume contrast medium injection (65 mL). This allows for accurate CT measurements of the aortic annulus, recruitment of patients for TAVI and facilitates pre-procedural planning in these high surgical risk patients.
引用
收藏
页数:8
相关论文
共 2 条
  • [1] Feasibility of Ultra-Low Volume Contrast- Saline Mixture Injection With Dual-Flow Technique in a Pre-TAVI Computed Tomography Angiography
    Gallo, Giuseppe S.
    Caruso, Calogero
    Iannazzo, Erica
    Cannataci, Christine
    Gerasia, Roberta
    Tafaro, Corrado
    Gentile, Giovanni
    Mamone, Giuseppe
    Caruso, Settimo
    Marrone, Gianluca
    Gandolfo, Caterina
    Miraglia, Roberto
    HEART LUNG AND CIRCULATION, 2023, 32 (04): : 525 - 534
  • [2] Coronary angiography using second-generation dual source computed tomography Feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol-A CONSORT compliant article
    Zhu, Xiaomei
    Yu, Yusheng
    Xu, Dinghu
    Zhang, Hong
    Tang, Lijun
    MEDICINE, 2018, 97 (29)