Effects of injection type on slot film cooling for a ramjet combustor

被引:6
|
作者
Park, Kwang Hoon [1 ]
Yang, Kang Mo [1 ]
Lee, Keon Woo [1 ]
Cho, Hyung Hee [1 ]
Ham, Hee Chul [2 ]
Hwang, Ki Young [2 ]
机构
[1] Yonsei Univ, Dept Mech Engn, Seoul 120749, South Korea
[2] Agcy Def Dev, Taejon 300600, South Korea
关键词
Ramjet combustor; Slot film cooling; Recirculation flow; Heat transfer; Thermochromic liquid crystal (TLC);
D O I
10.1007/s12206-009-0614-y
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A slot film cooling technique has been used to protect a combustor liner from hot combustion gas. This method has been developed for gas turbine combustors. A ramjet combustor exposed to high temperature can be protected properly with a multi-slot film cooling method. An experimental study has been conducted to investigate the change of the first slot angle under recirculation flow and the influence of wiggle strip within a slot, which affects the film cooling effectiveness. The first slot angle has been changed to understand the effect of the injection angle on the film cooling effectiveness in a recirculation zone. The distribution of dimensionless temperature was obtained by a thermocouple rake to investigate the wiggle strip effect, and the adiabatic film cooling effectiveness on downstream wall was measured by a thermochromic liquid crystal (TLC) method. At the first slot position, the film cooling effectiveness decreases significantly because of the effects of recirculation flow. The lip angle of the first slot affects slightly on the film cooling effectiveness. The wiggle strip reinforces the structure of slot and keeps the uniform open area of slot. However, it induces three dimensional flows and enhances the flow mixing between the main flow and the injected slot flow. Therefore, the wiggle strip decreases slightly the overall film cooling effectiveness.
引用
收藏
页码:1852 / 1857
页数:6
相关论文
共 50 条
  • [1] Effects of injection type on slot film cooling for a ramjet combustor
    Kwang Hoon Park
    Kang Mo Yang
    Keon Woo Lee
    Hyung Hee Cho
    Hee Chul Ham
    Ki Young Hwang
    [J]. Journal of Mechanical Science and Technology, 2009, 23 : 1852 - 1857
  • [2] Slot film cooling performance in combustor with flame holders
    Song, Jiwoon
    Lee, Keon Woo
    Kim, Kyung Min
    Cho, Hyung Hee
    [J]. ENERGY, 2012, 37 (01) : 533 - 539
  • [3] FILM COOLING BY OBLIQUE SLOT INJECTION
    NILSON, RH
    TSUEI, YG
    [J]. AIAA JOURNAL, 1974, 12 (05) : 727 - 729
  • [4] Film cooling for slot injection in separated flows
    Okita, Y.
    Nakamata, C.
    Kamiya, H.
    Kumada, M.
    [J]. Proceedings of the ASME Turbo Expo 2005, Vol 3 Pts A and B, 2005, : 207 - 215
  • [5] Investigation on the enhanced cooling of ramjet engine combustor
    Gu, WZ
    Liu, WY
    Tu, JP
    [J]. HEAT TRANSFER 1998, VOL 5: GENERAL PAPERS, 1998, : 255 - 260
  • [6] Film cooling effectiveness for subsonic slot injection into a cross flow
    A. D. Fitt
    V. Stefanidis
    [J]. Acta Mechanica, 1998, 128 : 233 - 242
  • [7] Effects of the leading edge injection slot on the film cooling and heat transfer performance of the vane endwall
    Du, Kun
    Li, Zhigang
    Li, Jun
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 102 : 1308 - 1320
  • [8] AN EXPERIMENT STUDY OF LIQUID FILM COOLING ACCOMPLISHED BY DUAL SLOT INJECTION
    WARNER, CF
    GUINN, GR
    [J]. JOURNAL OF SPACECRAFT AND ROCKETS, 1966, 3 (10) : 1547 - &
  • [9] INFLUENCE OF FOREIGN GAS INJECTION AND SLOT GEOMETRY ON FILM COOLING EFFECTIVENESS
    BURNS, WK
    STOLLERY, JL
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1969, 12 (08) : 935 - &
  • [10] Cooling characteristics of ramjet engine combustor with inclined multihole heat shield
    Ding, Ji-Ping
    Ji, Hong-Hu
    Si, Ren
    [J]. Hangkong Dongli Xuebao/Journal of Aerospace Power, 2012, 27 (12): : 2699 - 2705